Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C14 with Circuit Breaker TA45
645
C14
70° C
Description
- Panel Mount: Screw-on mounting from front side - 2 Functions: Appliance Inlet Protection class I, circuit breaker type TA45 2-pole - Quick connect terminals 6.3 x 0.8 mm - Alternative: version with line filter 5145 - We recommend for new applications the new type DF11
Characteristics
- All single elements are already wired Unwired versions available on request - Line switch non-illuminated or illuminated Thermal overload protection Optional with undervoltage- or remote trip release - Qualified for use in equipment according IEC/EN 60950
References Weblinks
Approvals
General Product Information Approvals, RoHS, CHINA-RoHS, Mating Connectors, e-Store, Distributor-Stock-Check, Accessories
- VDE License Number: 117118 - UL License Number: E96454
Technical Data
Ratings IEC Ratings UL/CSA Dielectric Strength Allowable Operation Temp. Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 10 A / 250 VAC; 50 Hz 15 A / 250 VAC; 60 Hz > 1.5 kVAC between L/N-PE (1 min/50 Hz) -10 °C to 55 °C from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class 1 acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 6 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance Inlet C14 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class 1 Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltage- or remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In ≥ 3A/240VAC : 300A Rocker switch 2-pole, non-illuminated or illuminated, acc. to IEC 61058-1 Technical details
Circuit Breakers
Line Switch
Connectors
645
www.schurter.com/pg05 Dimensions
Detail A 2 36 43 1
Power entry modules without line filter
91.5 mm
29 +0.2
0
ø 3.25
6.3x0.8mm
ø6
R 3-0.5
0
91.5
80
6.3x0.8mm 24.2 67.5* 13.5 M3/ø 3.6
* --- Version TA45 with undervoltage release
Diagrams Diagram
1) Line 2) Load
Connectors
80 ±0.1
72
+0.1 0
Power entry modules without line filter www.schurter.com/pg05
645
Connectors
645
www.schurter.com/pg05 Packaging unit Accessories
Description
Power entry modules without line filter
20 Pcs
Assorted Covers Rear Cover 0859.0074
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal Appliance Outlet further types to 6145 Connector Overview complete IEC Connector C15, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Angled IEC Connector C13, Rewireable, Angled Connector further types to 6145 Power Cord Overview complete Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13 Power Cord further types to 6145 0311 3011 3012 3013 3020 ... 0101 0102 0102-G 0112 4012 ... 4787 4788 5091 5092
4
Connectors
Power entry modules without line filter www.schurter.com/pg05
645
Technical data (continued) Circuit breaker Tripping characteristics In < 3 A
[ min ] [ sec ] 10’000
Type Rated current TA45 In < 3 A 1-pole protected
Tripping characteristics In 3… 15 A
[ min ] [ sec ] 10’000
Type Rated current TA45 I n ≥ 3... ≤ 15 A 1-pole protected
60 30 20 10 5 200 100 1 50 20 10 5 2 1 0,5
Tripping time
60 30 20 10 5 200 100 1 50 20 10 5 2 1 0,5
Tripping time
2000 1000 500
Ambient temp.
2-pole protected +23 °C
2’000 1’000 500
Ambient temp.
2-pole protected +23 °C
0,3 0,2 0,1 1,05 1,32 2 3 4 [ x In ] 5 8 10
Multiple of rated current
0,3 0,2 0,1 1,05 1,32 2 3 4 [ x In ] 5 8 10
Multiple of rated current
Effect of ambient temperature 1) The unit is calibrated for an ambient temperature of +23 °C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [°C] Correction factor –10 0,89 –5 0,91 0 0,92 +23 1,00 +30 1,03 +40 1,08 +55 1,16
* Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached.
1) Example Rated current at +23 °C Ambient temperature Correction factor Chosen rated current at + 40 °C ambient temperature
6,0 A +40 °C 1,08 6 A x 1,08 = 6,5 A
Order code (Order example) Type Order code TA 45 (2-pole rocker-switch without accessories) Wiring 0 Without 1 With 2 Special (on request)
6145 . A B T W F 1 5 0 C 0 see table 1
.001
0 Without line filter 0 Without line filter
Please note that Schurter will establish an internal part number for logistical use in addition to the order code. The format of this internal part number is, for example 6145.0031.001
The specifications, descriptions and illustrations indicated in this document are based on Connectors current information. All content is subject to modifications and amendments.
5