SBR40100
Elektronische Bauelemente VOLTAGE 100 V 40.0 Amp Schottky Barrier Rectifiers
RoHS Compliant Product A suffix of “-C” specifies halogen & lead-free
TO-247
FEATURES
Low forward voltage drop High current capability High reliability High surge current capability Epitaxial construction
A E F O C N B
MECHANICAL DATA
Case: Molded plastic Epoxy: UL94V-0 rate flame retardant Lead: Lead solderable per MIL-STD-202 method 208 guaranteed Polarity: As Marked Mounting position: Any Weight: 6.1 grams (Approximately)
D
L H M K G J
Pin 1 Pin 3
Pin 2 Case
REF. A B C D E F G
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Rating 25°C ambient temperature unless otherwise specified.
Single phase half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%.
Millimeter Min. Max. 15.38 16.20 4.20 5.36 20.63 22.38 21.50 7.87 8.13 4.32 7.20 5.20 5.70
REF. H J K L M N O
Millimeter Min. Max. 1.98 REF. 0.45 0.85 2.80 3.10 4.50 2.92 3.23 3.25 Ø 3.65 Ø 30°
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage Working Peak Reverse Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current, See Fig. 1
SYMBOL
VRRM VRSM VDC Per Leg Per Device IF IFSM VF IR CJ RθJA dv / dt TJ TSTG
VALUES
100 100 100 20 40 250 0.87 0.70 0.05 12 500 2.0 10000 -50 ~ +150 -65 ~ +175
UNITS
V V V A A V mA pF °C / W V / µs °C °C
Peak Forward Surge Current, 8.3 ms single half sine-wave Superimposed on rated load (JEDEC method) Maximum Instantaneous Forward Voltage (IF=20 A, TA = 25°C, per leg) Maximum Instantaneous Forward Voltage (IF=20 A, TA = 125°C, per leg) Maximum DC Reverse Current at TA = 25°C Rated DC Blocking Voltage TA = 125°C Typical Junction Capacitance (Note 1) Typical Thermal Resistance (Note 2) Voltage Rate of Chance (Rated VR) Operating Temperature Range Storage Temperature Range
NOTES: 1. Measured at 1MHz and applied reverse voltage of 5.0V D.C. 2. Thermal Resistance Junction to Case.
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
16-Nov-2009 Rev. C
Page 1 of 2
SBR40100
Elektronische Bauelemente VOLTAGE 100 V 40.0 Amp Schottky Barrier Rectifiers
RATINGS AND CHARACTERISTIC CURVES
Typical Forward Current Derating Curve
30
Typical Forward Characteristic
200
Average Forward Current (A); per Leg
20
Instantaneous Forward Current (A)
20 125¢J
75¢J 100¢J
10
50¢J
2 25¢J
0 20 50 100 150 190
Tc, Case Temperature (¢J )
Typical Junction Capacitance
1600
0. 2 0. 4
0. 5
0. 6
0. 7
0. 8
0. 9
1. 0
Forward Voltage (V)
Junction Capacitance (pF)
1200
800
Typical Reverse Characteristic
400
10 125¢J
0
0.1
1
10
100
100¢J
Revise Voltage (%)
1
Maximum Non- Repetitive Forward Surge Current
Reverse Current(mA)
300
75¢J
Peak Forwad surge Current (A)
50¢J 0. 1
240
Tj=25¢J
8.3mS Single half Sine Wave JEDEC Method
180
120
0. 01
25¢J
60
0 0 10 100
0. 001 10
30
50
70
90
110
Number of Cycles at 60Hz
Reverse Voltage(V)
http://www.SeCoSGmbH.com/
Any changes of specification will not be informed individually.
16-Nov-2009 Rev. C
Page 2 of 2