1N5711QCSM
MECHANICAL DATA Dimensions in mm (inches)
2 .2 9 ± 0 .2 0 (0 .0 9 ± 0 .0 0 8 )
1 .6 5 ± 0 .1 3 (0 .0 6 5 ± 0 .0 0 5 ) 0 .6 4 ± 0 .0 6 (0 .0 2 5 ± 0 .0 0 3 )
1 .4 0 ± 0 .1 5 (0 .0 5 5 ± 0 .0 0 6 )
"
A
$ #
0 .2 3 ra d . (0 .0 0 9 ) A= 1 .2 7 ± 0 .1 3 (0 .0 5 ± 0 .0 0 5 )
6 .2 2 ± 0 .1 3 (0 .2 4 5 ± 0 .0 0 5 )
LCC2
Underside View
PAD 1 = COMMON K1 PAD 2 = A1a PAD 3 =A2a PAD 4 = COMMON K2 PAD 5 = A2b PAD 6 = A1b
ABSOLUTE MAXIMUM RATINGS (TMB = 25°C unless otherwise stated)
VRRM IF Ptot Tcase Tstg Rth Repetitive Peak Reverse Voltage Forward Continuous Current TA = 25°C Power Dissipation TA = 25°C Operating Temperature Range Storage Temperature Range Junction–Ambient 70V 15mA 430mW –55 to +125°C –65 to +150°C TBA
ELECTRICAL CHARACTERISTICS (TA = 25°C unless otherwise stated)
Parameter
IR* VF* V(BR) C t Reverse Current Forward Voltage Breakdown Voltage Capacitance Effective Minority Carrier Lifetime
Test Conditions
Tamb = 25°C Tamb = 25°C Tamb = 25°C Tamb = 25°C Tamb = 25°C f = 1MHZ Tamb = 25°C IF = 5mA VR = 50V IF = 1mA IF = 15mA IR = 10mA VR = 0V
4 .3 2 ± 0 .1 3 (0 .1 7 0 ± 0 .0 0 5 )
!
DUAL COMMON CATHODE PAIR SCHOTTKY DIODES IN HERMETIC CERAMIC SURFACE MOUNT PACKAGE FOR HIGH RELIABILITY APPLICATIONS
2 .5 4 ± 0 .1 3 (0 .1 0 ± 0 .0 0 5 )
Min.
Typ.
Max.
0.2 0.41 1
Unit
m
A
V V
70 2 100
PF ps
* Pulse test £ 300ms , d £ 2%
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use. Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc.
Telephone +44(0)1455 556565. Fax +44(0)1455 552612. E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
Document Number 2537 Issue 1