0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
142PC01D-PCB

142PC01D-PCB

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    142PC01D-PCB - Signal conditioned precision pressure transducers - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
142PC01D-PCB 数据手册
140PC...-PCB Series Signal conditioned precision pressure transducers FEATURES · 1 to 150 psi absolute, gage or differential pressure (custom calibrations available) · 1...6 V output · Output ratiometric to supply voltage · Precision temperature compensated and calibrated · Special calibrations for small volumes on request · EMC-proof SERVICE Non-corrosive, non-ionic working fluids, such as dry air and dry gases Scale: 1 cm 1 inch SPECIFICATIONS Maximum ratings Supply voltage Maximum load current Source Sink Temperature limits Storage Operating Compensated Lead temperature (10 sec. soldering) Humidity limits Pressure inlets only Proof pressure1 All 1 psi, 3 psi, 5 psi devices All 15 psi devices All 30 psi devices All 100 psi devices All 150 psi devices 7...16 V 10 mA 5 mA ELECTRICAL CONNECTION +Vs -55 to 100°C -40 to 85°C 0 to 70°C 7 V to 16 V (NOM 8.00 V) 140PC...-PCB 300°C Vout V -Vs 0 - 98 %RH 20 psi 30 psi 60 psi 150 psi 200 psi March 2006 / 554 1/4 www.sensortechnics.com 140PC...-PCB Series Signal conditioned precision pressure transducers PERFORMANCE CHARACTERISTICS (unless otherwise noted VS = 8.00 ±0.01 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure vacuum gage devices2 141PC01G-PCB 141PC05G-PCB 141PC15G-PCB 141PC30G-PCB 141PC100G-PCB 142PC01D-PCB 142PC05D-PCB 142PC15D-PCB 142PC30D-PCB 142PC100D-PCB 142PC150D-PCB 142PC15A-PCB 142PC30A-PCB 142PC100A-PCB 143PC01D-PCB 143PC03D-PCB 143PC05D-PCB 143PC15D-PCB 141PC.../142PC...-PCB 143PC...-PCB 141PC.../142PC...-PCB 143PC...-PCB 143PC...-PCB all 1 psi devices all others Min. -1 -5 -15 -30 -100 0 0 0 0 0 0 0 0 0 -1 -2.5 -5 -15 0.95 3.45 4.95 2.45 5.90 Typ. Max. 0 0 0 0 0 1 5 15 30 100 150 15 30 100 1 2.5 5 15 1.05 3.55 5.05 2.55 6.10 0.5 ±3.0 ±1.0 Unit p si g (vacuum) differential devices3 psid(g) absolute devices3 p si a pressure/vacuum devices3 psid(g) Zero pressure offset Full scale span4 Full scale output Output at lowest specified pressure Non-linearity and hysteresis (BSL)5 Thermal effects6 Combined offset and span (0 to 70°C) Long term stability7 Response time (10 to 90%) Current consumption Radiated, radio frequency electromagnetic field immunity (RFI) EN6100-4-3 grade 3, 80 to 1000 MHz, 80 % AMC (1 KHz) 1.00 3.50 5.00 2.50 6.00 1.00 0.1 ±1.5 ±0.5 ±0.1 0.1 4.5 V %FSO ms mA V/m 10 Specification notes: 1. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 2. The output signal of all 141PC...-PCB devices is proportional to the vacuum applied to port A, relative to port B, e. g. the output signal increases when pressure is applied to port B relative to port A. 3. The output signal of all 142PC...D-PCB and 143PC...D-PCB devices is proportional to the pressure applied to port A, relative to port B, e.g. the output signal increases when vacuum is applied to port B relative to port A. 4. Full scale span is the algebraic difference between the positive full scale output and the zero pressure offset. 5. Non-linearity refers to the Best Straight Line fit measured for offset pressure, full scale pressure and 1/2 full scale pressure. 6. Thermal effects tested and guaranteed from 0 - 70°C relative to 25°C. All specifications shown are relative to 25°C. 7. Change in output after one year or 1 million pressure cycles. 2/4 March 2006 / 554 www.sensortechnics.com 140PC...-PCB Series Signal conditioned precision pressure transducers OUTPUT CHARACTERISTICS Vacuum gage devices 141PC...-PCB 6 Vout 5 V 4 3 2 1 -100 -80 -60 -40 -20 0 % full scale pressure (vacuum) Differential devices 142PC...-PCB 6 Vout 5 V 4 3 2 1 0 20 40 60 80 100 % full scale pressure Pressure/vacuum devices 143PC...-PCB 6 Vout 5 V 4 3 2 1 0 -100 3.5V -50 0 50 100 % full scale pressure March 2006 / 554 3/4 www.sensortechnics.com 140PC...-PCB Series Signal conditioned precision pressure transducers OUTLINE DRAWING 30.0 port A (high pressure) 14.0 18.3 2 x 5.08 typ. 22.7 1 2 3 12.6 connection +Vs -Vs Vout 31.5 9.1 3 terminals 0.56 diam. 59.8 52.4 10.7 3,4 4.8 diam. 3.2 diam. 2 x mounting holes NOM 6.0 pin 1 2 3 mass: 20 g dimensions in mm ORDERING INFORMATION Operating pressure Vacuum gage devices 0 to -1 psig 0 to -5 psig 0 to -15 psig 0 to -30 psig 0 to -100 psig Differential / gage devices 0 to 1 psid(g) 0 to 5 psid(g) 0 to 15 psid(g) 0 to 30 psid(g) 0 to 100 psid(g) 0 to 150 psid(g) Absolute devices 0 to 15 psia 0 to 30 psia 0 to 100 psia Pressure/vacuum devices 0 to ±1 psid(g) 0 to ±2.5 psid(g) 0 to ±5 psid(g) 0 to ±15 psid(g) 143PC01D-PCB 143PC03D-PCB 143PC05D-PCB 143PC15D-PCB 142PC15A-PCB 142PC30A-PCB 142PC100A-PCB 142PC01D-PCB 142PC05D-PCB 142PC15D-PCB 142PC30D-PCB 142PC100D-PCB 142PC150D-PCB 141PC01G-PCB 141PC05G-PCB 141PC15G-PCB 141PC30G-PCB 141PC100G-PCB part number Custom calibrations available Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. 4/4 March 2006 / 554 www.sensortechnics.com
142PC01D-PCB 价格&库存

很抱歉,暂时无法提供与“142PC01D-PCB”相匹配的价格&库存,您可以联系我们找货

免费人工找货