BTE2002G1C

BTE2002G1C

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    BTE2002G1C - Precision stainless steel pressure transmitters - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
BTE2002G1C 数据手册
BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters FEATURES · 0...0.35 to 0...35 bar, 0...5 to 0...500 psi gage1 · For corrosive media in harsh environments · 1...6 V or 4...20 mA output · Field interchangeable · All welded stainless steel diaphragm construction MEDIA COMPATIBILITY Wetted materials: stainless steel 1.4404 (316) Housing: stainless steel 1.4305 (303), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1 SPECIFICATIONS8,9 Maximum ratings Supply voltage (reverse polarity protection) 12...30 V BTE(M)/PTE2...G1... 12...36 V BTE(M)/PTE2...G4...2 Maximum load current BTE(M)/PTE2...G1... only Temperature limits Storage Operating Media Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure BTEM2350... PTE2005... all others 3 ELECTRICAL CONNECTION 1...6 V output version +Vs Sensor 1 12 V to 30 V Vout 2 -Vs 4 GND V 20 mA -55 to 100°C -40 to 100°C -40 to 125°C 0 to 70°C 0 - 100 %RH 2g 50 g 1000 mbar 15 psi 2 x rated pressure Sensor Case 3 4...20 mA output version +Vs 1 12 V to 36 V V -Vs 4 Case 3 RL GND December 2008 / 098 1/6 www.sensortechnics.com BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters COMMON PERFORMANCE CHARACTERISTICS1 Characteristics Operating pressure BTEM2350... BTE2001... BTE2002... BTE2005... BTE2010... BTE2020... BTE2025... BTE2035... PTE2005... PTE2015... PTE2030... PTE2100... PTE2300... PTE2500... Min. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Typ. Max. 0.35 1 2 5 10 20 25 35 5 15 30 100 300 500 Unit bar p si g BTEM.../PTE2005... all others (-40 to 0°C, 70 to 100°C) Frequency response (10 to 90 %) Power supply rejection Offset Span Repeatability Long term stability5 Output noise Non-linearity and hysteresis (BSL)6 Thermal effects4 (0 to 70°C) (combined offset and span) ±0.1 ±0.2 ±0.04 ±0.2 ±0.6 ±0.5 ±2.0 1 0.05 0.03 ±0.5 ±2.5 ±1.5 %FSO ms %FSO/V INDIVIDUAL PERFORMANCE CHARACTERISTICS1 1...6 V output version (unless otherwise noted, VS = 15 V, tamb = 25°C, RL > 100 kOhm) Characteristics Zero pressure offset Full scale span Full scale output Output impedance Power consumption (no load) Min. 0.90 4.95 Typ. 1.00 5.00 6.0 100 Max. 1.10 5.05 50 Unit V Ω mW 4...20 mA output version (unless otherwise noted, VS = 15 V, tamb = 25°C, RL = 100 Ohm) Characteristics Zero pressure offset Full scale span Full scale output Power consumption (IL = 20 mA) Min. 3.9 15.9 Typ. 4.0 16.0 20.0 260 Max. 4.1 16.1 Unit mA mW December 2008 / 098 2/6 www.sensortechnics.com BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters Specification notes: 1. IP 65 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Long term stability is the change in output after one year or 1 million pressure cycles. 6. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 7. Tests are in accordance with EN61000-6-2, April 1999. 8. CE-labelling is in accordance with 89/336/EEC. 9. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. ELECTROMAGNETIC CAPABILITY7 Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) Grade 3 ±2 kV Grade 4 ±8 kV, contact discharge Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz) Criterion A B B A Interference
BTE2002G1C 价格&库存

很抱歉,暂时无法提供与“BTE2002G1C”相匹配的价格&库存,您可以联系我们找货

免费人工找货