BTE2010G1C 数据手册
BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters FEATURES · 0...0.35 to 0...35 bar, 0...5 to 0...500 psi gage1 · For corrosive media in harsh environments · 1...6 V or 4...20 mA output · Field interchangeable · All welded stainless steel diaphragm construction MEDIA COMPATIBILITY Wetted materials: stainless steel 1.4404 (316) Housing: stainless steel 1.4305 (303), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1 SPECIFICATIONS8,9 Maximum ratings Supply voltage (reverse polarity protection) 12...30 V BTE(M)/PTE2...G1... 12...36 V BTE(M)/PTE2...G4...2 Maximum load current BTE(M)/PTE2...G1... only Temperature limits Storage Operating Media Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure BTEM2350... PTE2005... all others 3 ELECTRICAL CONNECTION 1...6 V output version +Vs Sensor 1 12 V to 30 V Vout 2 -Vs 4 GND V 20 mA -55 to 100°C -40 to 100°C -40 to 125°C 0 to 70°C 0 - 100 %RH 2g 50 g 1000 mbar 15 psi 2 x rated pressure Sensor Case 3 4...20 mA output version +Vs 1 12 V to 36 V V -Vs 4 Case 3 RL GND December 2008 / 098 1/6 www.sensortechnics.com BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters COMMON PERFORMANCE CHARACTERISTICS1 Characteristics Operating pressure BTEM2350... BTE2001... BTE2002... BTE2005... BTE2010... BTE2020... BTE2025... BTE2035... PTE2005... PTE2015... PTE2030... PTE2100... PTE2300... PTE2500... Min. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Typ. Max. 0.35 1 2 5 10 20 25 35 5 15 30 100 300 500 Unit bar p si g BTEM.../PTE2005... all others (-40 to 0°C, 70 to 100°C) Frequency response (10 to 90 %) Power supply rejection Offset Span Repeatability Long term stability5 Output noise Non-linearity and hysteresis (BSL)6 Thermal effects4 (0 to 70°C) (combined offset and span) ±0.1 ±0.2 ±0.04 ±0.2 ±0.6 ±0.5 ±2.0 1 0.05 0.03 ±0.5 ±2.5 ±1.5 %FSO ms %FSO/V INDIVIDUAL PERFORMANCE CHARACTERISTICS1 1...6 V output version (unless otherwise noted, VS = 15 V, tamb = 25°C, RL > 100 kOhm) Characteristics Zero pressure offset Full scale span Full scale output Output impedance Power consumption (no load) Min. 0.90 4.95 Typ. 1.00 5.00 6.0 100 Max. 1.10 5.05 50 Unit V Ω mW 4...20 mA output version (unless otherwise noted, VS = 15 V, tamb = 25°C, RL = 100 Ohm) Characteristics Zero pressure offset Full scale span Full scale output Power consumption (IL = 20 mA) Min. 3.9 15.9 Typ. 4.0 16.0 20.0 260 Max. 4.1 16.1 Unit mA mW December 2008 / 098 2/6 www.sensortechnics.com BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters Specification notes: 1. IP 65 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Long term stability is the change in output after one year or 1 million pressure cycles. 6. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 7. Tests are in accordance with EN61000-6-2, April 1999. 8. CE-labelling is in accordance with 89/336/EEC. 9. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. ELECTROMAGNETIC CAPABILITY7 Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) Grade 3 ±2 kV Grade 4 ±8 kV, contact discharge Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz) Criterion A B B A Interference
BTE2010G1C
1. 物料型号: - 该文档描述的是BTE2000/PTE2000系列精密不锈钢压力变送器。 - 1...6 V输出版本型号:BTEM2350G1A、BTE2001G1A、BTE2002G1A、BTE2005G1A、BTE2010G1A等。 - 4...20 mA输出版本型号:PTE2005G1A、PTE2015G1A、PTE2030G1A、PTE2100G1A、PTE2300G1A等。

2. 器件简介: - 这些变送器适用于恶劣环境下的腐蚀性介质,具有全焊接不锈钢膜片结构,现场可互换,输出1...6V或4...20mA。

3. 引脚分配: - 连接器版本: - 1号引脚:+Vs(1...6V)/NC(4...20mA) - 2号引脚:Vout(1...6V)/NC(4...20mA) - 3号引脚:Case(接地) - 4号引脚:-Vs(1...6V)/-Vs(4...20mA) - 电缆版本: - 裸露线:屏蔽 - 棕色线:+Vs(1...6V)/NC(4...20mA) - 白线:NC - 绿色线:Vout(1...6V)/NC(4...20mA) - 黄线:-Vs(1...6V)/-Vs(4...20mA)

4. 参数特性: - 供电电压:12...30V(1...6V输出版本)/12...36V(4...20mA输出版本) - 工作温度范围:-40至100°C - 存储温度范围:-55至100°C - 耐压:1000 mbar(15 psi)/两倍额定压力

5. 功能详解: - 这些变送器具备反向极性保护、温度限制、湿度限制、振动和机械冲击测试。

6. 应用信息: - 主要应用于测量0...0.35至0...35 bar或0...5至0...500 psi gage的压力。

7. 封装信息: - 外壳材料为不锈钢1.4305(303),保护等级为IP 65(根据DIN EN 60529)/NEMA 4X。 - 典型重量为190克。