BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
FEATURES · 25 mbar to 10 bar or 0.3 to 150 psi differential pressure · High level output , 1...6 V or 4...20 mA (2-wire connection)12 · Precision temperature compensated and calibrated · Rugged aluminium housing · Female 1/8" BSP and 1/8" NPT fittings
MEDIA COMPATIBILITY
Pressure inlet: Non-corrosive, non-ionic working fluids such as air, dry gases and the like Housing: Aluminium, protection class IP 67 (according to DIN EN 60529) respectively NEMA 61
ELECTRICAL CONNECTION SPECIFICATIONS10,11
Maximum ratings Supply voltage Output current BTE(M)/PTE/PTU5...D1... Source Sink Output current BTE(M)/PTE/PTU5...D4... Temperature limits Storage Operating Compensated 12...32 V
Sensor
1...6 V output version
+Vs Vout -Vs case 1 2 4 3 GND
V
12 to 32 V
20 mA 10 mA 30 mA -55 to 100°C -40 to 85°C 0 to 70°C
4...20 mA output version
+Vs 1 Sensor -Vs 4 12 to 32 V
Proof pressure2 BTEM5x025... / PTx5000.3... 0.35 bar / 5 psi BTEM5x070..., BTEM5x350... / 1.4 bar / 20 psi PTx5001..., PTx5005... all others 2 x rated pressure Pressure at any port3 12 bar / 175 psi
V
RL
GND
case 3
June 2008 / 101
1/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
COMMON PERFORMANCE CHARACTERISTICS8
Characteristics
Operating pressure BTEM50025... BTEM5P025... BTEM50070... BTEM5P070... BTEM50350... BTEM5P350... BTE5001... BTE5P01... BTE5002... BTE5005... BTE5010... PTU5000.3... PTx5001... PTx5P01... PTx5005... PTx5P05... PTx5015... PTx5P15... PTx5030... PTx5100... PTx5150... Thermal effects (0 to 70°C)6 Offset all ≤ 70 mbar / 1 psid devices all 350 mbar / 5 psid devices all others
Min.
0 -25 0 -70 0 -350 0 -1 0 0 0 0 0 -1 0 -5 0 -15 0 0 0
Typ.
Max.
25 25 70 70 350 350 1 1 2 5 10 0.3 1 1 5 5 15 15 30 100 150
Unit
mbar
bar
p si d
Span Non-linearity and hysteresis4 Long term stability5 Output noise (0 ≤ f ≤ 1 kHz) Response time (10 to 90 %)
±0.025 ±0.008 ±0.005 ±0.001 ±0.2 ±0.2 0.04 1
±0.125 ±0.040 ±0.025 ±0.045 ±1
%FSO/°C
%FSO
ms
June 2008 / 101
2/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
PERFORMANCE CHARACTERISTICS8
1...6 V output versions (unless otherwise noted VS = 15 V, tamb = 25°C, RL > 100 kΩ, com. mode pressure = 0)
Characteristics
Zero pressure offset Full scale span7 Full scale output Power supply rejection Output impedance Power consumption Offset Span BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others
Min.
3.4 0.9 2.4 4.9
Typ.
3.5 1.0 2.5 5.0 6.0 0.05 0.03
Max.
3.6 1.1 2.6 5.1
Unit
V
%FSO/V 50 Ω mW
60
4...20 mA output versions (unless otherwise noted VS = 15 V, tamb = 25°C, RL = 100 Ω, com. mode pressure = 0)
Characteristics
Zero pressure offset Full scale span7 Full scale output Power supply rejection Output impedance Power consumption (IL = 20 mA) Offset Span BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others
Min.
11.9 3.9 7.9 15.9
Typ.
12.0 4.0 8.0 16.0 20.0 0.05 0.03
Max.
12.1 4.1 8.1 16.1
Unit
mA
%FSO/V 0.1 Ω mW
260
Specification notes:
1. IP 67 protection for BTE(M)5...A / PTx5...A is given with locked connector only. 2. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 3. This is the highest pressure which can be applied to any port at any time. At the same time the differential pressure between the ports H and L must not exceed the maximum proof pressure. 4. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 5. Long term stability is the change in output after one year or 1 million pressure cycles. 6. Thermal effects tested and guaranteed from 0 - 70 °C relative to 25°. All specifications shown are relative to 25°C. 7. Full scale span is the algebraic difference between the positive full scale output and zero pressure offset. 8. Higher pressure applied to port H. 9. Test are in accordance with EN61000-6-2, April 1999. 10. CE-labelling is in accordance with 89/336/EEC. 11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 12. 0...10 V square rooting output signal on special request.
June 2008 / 101
3/6
www.sensortechnics.com
BTE5000 / PTE5000 / PTU5000 Series
Precision differential pressure transmitters
ELECTROMAGNETIC CAPABILITY9
Test conditions
Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) Grade 3 ±2 kV Grade 4 ±8 kV, contact discharge Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz)
Criterion
A B B A
Interference
很抱歉,暂时无法提供与“BTE5001D1C”相匹配的价格&库存,您可以联系我们找货
免费人工找货