BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
FEATURES · 0...-1 to 0...350 bar, 0...-15 to 0...5000 psi gage1 or absolute11 · For corrosive media · Flush mount versions · 0...10 V, 1...6 V, 0...20 mA, 4...20 mA output · Field interchangeable · For harsh environments
MEDIA COMPATIBILITY
Wetted materials: stainless steel 1.4404 (316L), NBR12 Housing: stainless steel 1.4404 (316L), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1
ELECTRICAL CONNECTION
0...10 V, 1...6 V output
+Vs sensor 1 Vout 3 -Vs 2
13 to 30 V
V
SPECIFICATIONS9,10
Maximum ratings
0...20 mA output
GND
Supply voltage (reverse polarity protection) 13...30 V BTE(M)/PTU6...0, ...1 12...36 V BTE(M)/PTU6...4, ...52 Maximum load current BTE(M)/PTU6...0, ...1 Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure
3
sensor
10 mA -55 to 100°C -40 to 100°C 0 to 70°C 0 - 95 %RH 10 gRMS 50 g 2 x rated pressure
sensor
+Vs 1 Iout 3 -Vs 2
12 to 36 V
RL
V
GND
4...20 mA output
+Vs 1 N/C 3 -Vs 2
12 to 36 V
V
RL GND
December 2008 / 102
1/8
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
COMMON PERFORMANCE CHARACTERISTICS1
Characteristics
Operating pressure BTEM6200... BTEM6350... BTE6001... BTE6N01... BTE6P01... BTE6002... BTE6005... BTE6010... BTE6016... BTE6035... BTE6070... BTE6350... PTU6003... PTU6005... PTU6015... PTU6N15... PTU6P15... PTU6030... PTU6100... PTU6250... PTU6500... PTU61K0... PTU65K0... Thermal effects (0 to 70°C)4 200/300 mbar, 3/5 psi only Thermal effects (-40 to 0°C, 70 to 100°C) Non-linearity and hysteresis (BSL)5 Repeatability Long term stability6 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span Offset Span Offset Span Offset Span 0.03 0.03 ±0.1 ±0.1 ±0.2 ±0.04 1 0.05 0.05 ms %FSO/V ±0.5 %FSO
Min.
0 0 0 -1 -1 0 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 0
Typ.
Max.
200 350 1 +1 0 2 5 10 16 35 70 350 3 5 15 +15 0 30 100 250 500 1000 5000
Unit
mbar
bar
p si
0.01 0.01
0.03 0.03 0.06 0.04 %FSO/°C
December 2008 / 102
2/8
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS1
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Power consumption (no load) BTE/PTU6N... all others BTE/PTU6N... all others
Min.
4.85 -0.15 4.9 9.9
Typ.
5.0 0 5.0 10.0 100
Max.
5.15 0.15 5.1 10.1 50
Unit
V Ω mW
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Power consumption (no load) BTE/PTU6N... all others BTE/PTU6N... all others
Min.
3.35 0.85 2.4 4.9
Typ.
3.5 1.0 2.5 5.0 6.0 100
Max.
3.65 1.15 2.6 5.1 50
Unit
V Ω mW
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Power consumption (IL = 20 mA) BTE/PTU6N... all others BTE/PTU6N... all others
Min.
11.85 3.85 7.9 15.9
Typ.
12.0 4.0 8.0 16.0 0.1 260
Max.
12.15 4.15 8.1 16.1
Unit
mA Ω mW
0...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Power consumption (IL = 20 mA) BTE/PTU6N... all others BTE/PTU6N... all others
Min.
9.85 -0.15 9.9 19.9
Typ.
10.0 0 10.0 20.0 0.1 260
Max.
10.15 0.15 10.1 20.1
Unit
mA Ω mW
December 2008 / 102
3/8
www.sensortechnics.com
BTE6000 / PTU6000 Series
Precision stainless steel pressure transmitters
Specification notes:
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. Non-linearity refers to the B est S traight L ine fit measured for offset, full scale span and 1/2 full scale span. Long term stability is the change in output after one year or 1 million pressure cycles. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. Test are in accordance with EN61000-6-2, April 1999. CE-labelling is in accordance with 89/336/EEC. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. Other sealing materials are available on request.
ELECTROMAGNETIC CAPABILITY8
Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields Test conditions Criterion Interference EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A
很抱歉,暂时无法提供与“BTE6002A0-FL”相匹配的价格&库存,您可以联系我们找货
免费人工找货