BTEM50025D4C

BTEM50025D4C

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    BTEM50025D4C - Precision differential pressure transmitters - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
BTEM50025D4C 数据手册
BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters FEATURES · 25 mbar to 10 bar or 0.3 to 150 psi differential pressure · High level output , 1...6 V or 4...20 mA (2-wire connection)12 · Precision temperature compensated and calibrated · Rugged aluminium housing · Female 1/8" BSP and 1/8" NPT fittings MEDIA COMPATIBILITY Pressure inlet: Non-corrosive, non-ionic working fluids such as air, dry gases and the like Housing: Aluminium, protection class IP 67 (according to DIN EN 60529) respectively NEMA 61 ELECTRICAL CONNECTION SPECIFICATIONS10,11 Maximum ratings Supply voltage Output current BTE(M)/PTE/PTU5...D1... Source Sink Output current BTE(M)/PTE/PTU5...D4... Temperature limits Storage Operating Compensated 12...32 V Sensor 1...6 V output version +Vs Vout -Vs case 1 2 4 3 GND V 12 to 32 V 20 mA 10 mA 30 mA -55 to 100°C -40 to 85°C 0 to 70°C 4...20 mA output version +Vs 1 Sensor -Vs 4 12 to 32 V Proof pressure2 BTEM5x025... / PTx5000.3... 0.35 bar / 5 psi BTEM5x070..., BTEM5x350... / 1.4 bar / 20 psi PTx5001..., PTx5005... all others 2 x rated pressure Pressure at any port3 12 bar / 175 psi V RL GND case 3 June 2008 / 101 1/6 www.sensortechnics.com BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters COMMON PERFORMANCE CHARACTERISTICS8 Characteristics Operating pressure BTEM50025... BTEM5P025... BTEM50070... BTEM5P070... BTEM50350... BTEM5P350... BTE5001... BTE5P01... BTE5002... BTE5005... BTE5010... PTU5000.3... PTx5001... PTx5P01... PTx5005... PTx5P05... PTx5015... PTx5P15... PTx5030... PTx5100... PTx5150... Thermal effects (0 to 70°C)6 Offset all ≤ 70 mbar / 1 psid devices all 350 mbar / 5 psid devices all others Min. 0 -25 0 -70 0 -350 0 -1 0 0 0 0 0 -1 0 -5 0 -15 0 0 0 Typ. Max. 25 25 70 70 350 350 1 1 2 5 10 0.3 1 1 5 5 15 15 30 100 150 Unit mbar bar p si d Span Non-linearity and hysteresis4 Long term stability5 Output noise (0 ≤ f ≤ 1 kHz) Response time (10 to 90 %) ±0.025 ±0.008 ±0.005 ±0.001 ±0.2 ±0.2 0.04 1 ±0.125 ±0.040 ±0.025 ±0.045 ±1 %FSO/°C %FSO ms June 2008 / 101 2/6 www.sensortechnics.com BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters PERFORMANCE CHARACTERISTICS8 1...6 V output versions (unless otherwise noted VS = 15 V, tamb = 25°C, RL > 100 kΩ, com. mode pressure = 0) Characteristics Zero pressure offset Full scale span7 Full scale output Power supply rejection Output impedance Power consumption Offset Span BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others Min. 3.4 0.9 2.4 4.9 Typ. 3.5 1.0 2.5 5.0 6.0 0.05 0.03 Max. 3.6 1.1 2.6 5.1 Unit V %FSO/V 50 Ω mW 60 4...20 mA output versions (unless otherwise noted VS = 15 V, tamb = 25°C, RL = 100 Ω, com. mode pressure = 0) Characteristics Zero pressure offset Full scale span7 Full scale output Power supply rejection Output impedance Power consumption (IL = 20 mA) Offset Span BTE(M)5P... / PTx5P... all others BTE(M)5P... / PTx5P... all others Min. 11.9 3.9 7.9 15.9 Typ. 12.0 4.0 8.0 16.0 20.0 0.05 0.03 Max. 12.1 4.1 8.1 16.1 Unit mA %FSO/V 0.1 Ω mW 260 Specification notes: 1. IP 67 protection for BTE(M)5...A / PTx5...A is given with locked connector only. 2. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 3. This is the highest pressure which can be applied to any port at any time. At the same time the differential pressure between the ports H and L must not exceed the maximum proof pressure. 4. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 5. Long term stability is the change in output after one year or 1 million pressure cycles. 6. Thermal effects tested and guaranteed from 0 - 70 °C relative to 25°. All specifications shown are relative to 25°C. 7. Full scale span is the algebraic difference between the positive full scale output and zero pressure offset. 8. Higher pressure applied to port H. 9. Test are in accordance with EN61000-6-2, April 1999. 10. CE-labelling is in accordance with 89/336/EEC. 11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 12. 0...10 V square rooting output signal on special request. June 2008 / 101 3/6 www.sensortechnics.com BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters ELECTROMAGNETIC CAPABILITY9 Test conditions Radiated, radio frequency electromagnetic field immunity (RFI) Electrical fast transient / burst immunity (EFT) Electrostatic discharge immunity test (ESD) Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) Grade 3 ±2 kV Grade 4 ±8 kV, contact discharge Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz) Criterion A B B A Interference
BTEM50025D4C 价格&库存

很抱歉,暂时无法提供与“BTEM50025D4C”相匹配的价格&库存,您可以联系我们找货

免费人工找货