CTE7000 / CTU7000 Series
Miniature pressure transmitters
FEATURES · 0...10 mbar to 0...7 bar, 0...0.15 to 0...100 psi gage1 or absolute10 · 0...5 V, 0...10 V, 0.5...4.5 V or 4...20 mA output · Single supply · Field interchangeable · Rugged stainless steel housing
MEDIA COMPATIBILITY
Wetted materials: stainless steel 1.4404 (316), nylon, silicon, silicone-sealant and epoxy9 Housing: stainless steel, protection class IP 64 (according to DIN EN 60529) respectively NEMA 41
ELECTRICAL CONNECTION
0...10 V, 0.5...4.5 V, 0...5 V output
+Vs 12 (9) to 32 V
11
SPECIFICATIONS12,13
Maximum ratings Supply voltage (reverse polarity protection) CTE(M)/CTU7...011 12...32 V CTE(M)/CTU7...6, ...711 9...32 V CTE(M)/CTU7...42 9...32 V Maximum load current (source) CTE(M)/CTU7...0, ...6, ...7 Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock 4...20 mA output 1 mA -55 to 100°C -40 to 85°C 0 to 50°C 0 - 98 %RH 2 gRMS 50 g
sensor
1 Vout 2 -Vs 4 case 3
+Vs 1 N/C 2 -Vs 4 case 3
V GND
9 to 32 V
sensor
V RL GND
December 2008 / 507
1/6
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
COMMON PERFORMANCE CHARACTERISTICS
Characteristics
Operating pressure CTEM70010... CTEM7N010... CTEM70025... CTEM7N025... CTEM70070... CTEM7N070... CTEM70350... CTEM7N350... CTE7001... CTE7N01... CTE7P01... CTE7002... CTE7005... CTE7007... CTU700x15... CTU7N0x15... CTU700x3... CTU7N0x3... CTU7001... CTU7N01... CTU7005... CTU7N05... CTU7015... CTU7N15... CTU7P15... CTU7030... CTU7100... CTEM70010..., CTEM7N010.../ CTU700x15..., CTU7N0x15... CTEM70025..., CTEM7N025.../ CTU700x3..., CTU7N0x3... all others Span Thermal effects (-20 to 0°C, 50 to 70°C) Repeatability Long term stability
6
Min.
0 -10 0 -25 0 -70 0 -350 0 -1 -1 0 0 0 0 -0.15 0 -0.3 0 -1 0 -5 0 -15 -15 0 0
Typ.
Max.
10 10 25 25 70 70 350 350 1 1 0 2 5 7 0.15 0.15 0.3 0.3 1 1 5 5 15 15 0 30 100 0.08 0.08 0.04 0.04
Proof3
250 250 350 350 1000 1000 1000 1000 2 2 2 4 10 10 3.6 3.6 5 5 15 15 15 15 30 30 30 60 150
Unit
mbar
bar
p si
Thermal effects (0 to 50°C)4
Offset
%FSO/°C
Offset Span
0.03 0.03 ±0.2 ±0.1 ±0.5 ±0.04 1.0 ms ±0.50 %FS
Non-linearity and hysteresis (BSL)5
Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span CTE(M)/CTU7...0, ...6, ...7 CTE(M)/CTU7...4 CTE(M)/CTU7...0, ...6, ...7 CTE(M)/CTU7...4
0.002 0.05 0.002 0.08
%FSO/V
December 2008 / 507
2/6
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...7N... all others CT...7N... all others
Min.
4.9 -0.1 4.9 9.9
Typ.
5 0 5 10 4
Max.
5.1 0.1 5.1 10.1 25 9.5
Unit
V Ω mA
0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...7N... all others CT...7N... all others
Min.
2.450 0.450 1.950 3.950
Typ.
2.5 0.5 2 4 4
Max.
2.550 0.550 2.050 4.050 25 8.5
Unit
V Ω mA
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...7N... all others CT...7N... all others
Min.
2.45 -0.05 2.45 4.95
Typ.
2.5 0 2.5 5.0 4
Max.
2.55 0.05 2.55 5.05 25 8.5
Unit
V Ω mA
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Power consumption (IL = 20 mA) CT...7N... all others CT...7N... all others
Min.
11.8 3.8 7.8 15.8
Typ.
12.0 4.0 8.0 16.0 260
Max.
12.2 4.2 8.2 16.2
Unit
mA
mW
December 2008 / 507
3/6
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
Specification notes:
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Thermal effects tested and guaranteed from 0 to 50°C relative to 25°C. All specifications shown are relative to 25°C. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. Long term stability is the change in output after one year or 1 million pressure cycles. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. Tests are in accordance with EN61000-6-2, April 1999. When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. For sensors with max. operating pressure below 100 mbarg the max. supply voltage is 27 V. CE-labelling is in accordance with 89/336/EEC. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC.
OUTLINE DRAWING
NOM 72.0 (2.83) 6.5 (0.26) 52.0 (2.05) 4 vent hole¹
21.8 (0.86) diam.
G 1/8" (BSP)
1 3
M12 x 1
2
Detail A
Detail A
Output
3.4 (0.13) diam.
Pin 1 2 3 4 0...10 V 0.5...4.5 V 0...5 V +V S Vout case -Vs 4...20 mA +VS NC case -Vs
o-ring grove for o-ring 11.8 x 1.8 (0.456 x 0.071) (ZA004022)
mass: 60 g
dimensions in mm (inches)
December 2008 / 507
4/6
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
RECOMMENDED ACCESSORY (not included in delivery)
ZK000101: ZP000112-B: Connector/cable assembly (different cable lenghts available) Mating Connector (without cable)
NOM 2 m
(other cable lenghts on request)
PIN CONNECTION Pin Flying lead end Brown Green White and shield Yellow
NOM 60
Shield
1 2 3
36.5
4
Vent tube
M12x1 Ø 20
Note: For proper function of all gage devices the vent tube must have access to the ambient atmosphere.
dimensions in mm
OPTIONAL PRESSURE FITTINGS (brass, nickel plated)
Male fittings
A B C
LOAD LIMITATION
4...20 mA output version
1400 Ohm 1200
D
1000 800
op e ra ratin ng g e
600
Female fittings
E
G F H
400 200 0 5 9
16 20 25 30 32 V supply voltage
Dimensions in mm (inches) A 1/8" BSPT 1/4" BSPT 3/8" BSPT 1/2" BSPT 1/8" BSP 1/4" BSP 3/8" BSP 1/8" NPT 1/4" NPT B 8 (0.315) 12 (0.472) 11.5 (0.453) 16 (0.630) 12.5 (0.492) 8.5 (0.335) 12.5 (0.492) 10 (0.394) 14 (0.551) C 13 (0.512) 5.5 (0.217) 5 (0.197) 7 (0.276) 11 (0.433) 5 (0.197) 7 (0.276) 13 (0.512) 6 (0.236) D (Hex.) 14 (9/16") 14 (9/18") 17 (11/16") 22 (7/8") 14 (9/16") 19 (3/4") 22 (7/8") 17 (11/16") 22 (7/8")
E 1/8" BSP 1/4" BSP 3/8" BSP 1/2" BSP
Dimensions in mm (inches) F 5 (0.197) 7 (0.276) 6 (0.236) 18 (0.707) G 15 (0.591) 20 (0.787) 20 (0.787) 23 (0.906) H (Hex.) 14 (9/16") 17 (11/16") 22 (7/8") 24 (15/16")
December 2008 / 507
5/6
www.sensortechnics.com
CTE7000 / CTU7000 Series
Miniature pressure transmitters
ELECTROMAGNETIC CAPABILITY8
Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A
很抱歉,暂时无法提供与“CTEM7N010AE7”相匹配的价格&库存,您可以联系我们找货
免费人工找货