CTEM9350GF0

CTEM9350GF0

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    CTEM9350GF0 - OEM pressure transmitters for industrial media - Sensortechnics GmbH

  • 详情介绍
  • 数据手册
  • 价格&库存
CTEM9350GF0 数据手册
CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media FEATURES · 0...0.35 to 0...35 bar, 0...5 to 0...500 psi gage1 or absolute10 · 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output · Field interchangeable · For industrial use · All welded stainless steel diaphragm construction MEDIA COMPATIBILITY Wetted materials: stainless steel 1.4404 (316)9 Housing: stainless steel, protection class IP 64 (according to DIN EN 60529) respectively NEMA 4X1 SPECIFICATIONS11,12 Maximum ratings Supply voltage (reverse polarity protection) CTE(M)/CTU9...0 12...32 V CTE(M)/CTU9...1, ...6, ...7 9...32 V CTE(M)/CTU9...42 9...32 V Maximum load current (source) CTE(M)/CTU9...0, ...1, ...6, ...7 Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure CTEM9350... CTU9005... all others 3 ELECTRICAL CONNECTION 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output +Vs 1 Vout 2 -Vs 4 case 3 V 12 (9) to 32 V sensor 1 mA GND -55 to 100°C -40 to 100°C 0 to 70°C 0 - 98 %RH 10 gRMS 50 g 4...20 mA output +Vs 1 N/C 2 -Vs 4 case 3 9 to 32 V sensor V RL GND 1000 mbar 15 psi 2 x rated pressure December 2008 / 509 1/6 www.sensortechnics.com CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media COMMON PERFORMANCE CHARACTERISTICS Characteristics Operating pressure CTEM9350... CTE9001... CTE9N01... CTE9P01... CTE9002... CTE9003... CTE9005... CTE9010... CTE9016... CTE9020... CTE9035... CTU9005... CTU9015... CTU9N15... CTU9P15 CTU9030... CTU9050... CTU9100... CTU9300... CTU9500... Thermal effects (0 to 70°C)4 Thermal effects (-40 to 0°C, 70 to 100°C) Offset Span Offset Span Min. 0 0 -1 -1 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 Typ. Max. 0.35 1 1 0 2 3 5 10 16 20 35 5 15 15 0 30 50 100 300 500 Unit bar p si ±0.02 ±0.02 ±0.03 ±0.03 ±0.2 ±0.1 ±0.05 ±0.05 %FSO/°C Non-linearity and hysteresis (BSL)5 Repeatability Long term stability6 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span CTE(M)/CTU9...4 all others CTE(M)/CTU9...4 all others ±0.5 %FSO ±0.1 ±0.04 1 ±0.05 ±0.002 ±0.08 ±0.002 %FSO/V ms December 2008 / 509 2/6 www.sensortechnics.com CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media INDIVIDUAL PERFORMANCE CHARACTERISTICS 0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. CT...9N... all others CT...9N... all others 4.9 -0.1 4.9 9.9 Typ. 5 0 5 10 4 Max. 5.1 0.1 5.1 10.1 25 9.5 Unit V Output impedance Current consumption (no load) Ω mA 0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...9N... all others CT...9N... all others Min. 2.45 0.45 1.95 3.95 Typ. 2.5 0.5 2 4 4 Max. 2.55 0.55 2.05 4.05 25 8.5 Unit V Ω mA 0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...9N... all others CT...9N... all others Min. 2.45 -0.05 2.45 4.95 Typ. 2.5 0 2.5 5.0 4 Max. 2.55 0.05 2.55 5.05 25 8.5 Unit V Ω mA 1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. CT...9N... all others CT...9N... all others 3.45 0.95 2.45 4.95 Typ. 3.5 1 2.5 5.0 4 Max. 3.55 1.05 2.55 5.05 25 8.5 Unit V Output impedance Current consumption (no load) Ω mA 4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. CT...9N... all others CT...9N... all others 11.8 3.8 7.8 15.8 Typ. 12.0 4.0 8.0 16.0 260 Max. 12.2 4.2 8.2 16.2 Unit mA Power consumption (IL = 20 mA) December 2008 / 509 mW 3/6 www.sensortechnics.com CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media Specification notes: 1. IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Tests are in accordance with EN61000-6-2, April 1999. 9. When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also. 10. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. 11. CE-labelling is in accordance with 89/336/EEC. 12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. OUTLINE DRAWING NOM 85.0 (3.35) 6.5 (0.26) 65.0 (2.56) 4 vent hole¹ 21.8 (0.86) diam. G 1/8" (BSP) 1 3 M12 x 1 2 Detail A Detail A Output Pin 1 2 3 4 0...10 V 0.5...4.5 V 0...5 V, 1...6 V +VS Vout case -Vs 4.0 (0.16) diam. 4...20 mA +VS NC case -Vs o-ring grove for o-ring 11.8 x 1.8 (0.456 x 0.071) (ZA004029) mass: 82 g dimensions in mm (inches) December 2008 / 509 4/6 www.sensortechnics.com CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media RECOMMENDED ACCESSORY (not included in delivery) ZK000101: ZP000112-B: Connector/cable assembly (different cable lenghts available) Mating Connector (without cable) NOM 2 m (other cable lenghts on request) PIN CONNECTION Pin Flying lead end Brown Green White and shield Yellow NOM 60 Shield 1 2 3 36.5 4 Vent tube M12x1 Ø 20 Note: For proper function of all gage devices the vent tube must have access to the ambient atmosphere. dimensions in mm OPTIONAL PRESSURE FITTINGS (brass, nickel plated) Male fittings A B C LOAD LIMITATION 4...20 mA output version 1400 Ohm 1200 D 1000 800 op e ra ratin ng g e 600 Female fittings E G F H 400 200 0 5 9 16 20 25 30 32 V supply voltage Dimensions in mm (inches) A 1/8" BSPT 1/4" BSPT 3/8" BSPT 1/2" BSPT 1/8" BSP 1/4" BSP 3/8" BSP 1/8" NPT 1/4" NPT B 8 (0.315) 12 (0.472) 11.5 (0.453) 16 (0.630) 12.5 (0.492) 8.5 (0.335) 12.5 (0.492) 10 (0.394) 14 (0.551) C 13 (0.512) 5.5 (0.217) 5 (0.197) 7 (0.276) 11 (0.433) 5 (0.197) 7 (0.276) 13 (0.512) 6 (0.236) D (Hex.) 14 (9/16") 14 (9/18") 17 (11/16") 22 (7/8") 14 (9/16") 19 (3/4") 22 (7/8") 17 (11/16") 22 (7/8") E 1/8" BSP 1/4" BSP 3/8" BSP 1/2" BSP Dimensions in mm (inches) F 5 (0.197) 7 (0.276) 6 (0.236) 18 (0.707) G 15 (0.591) 20 (0.787) 20 (0.787) 23 (0.906) H (Hex.) 14 (9/16") 17 (11/16") 22 (7/8") 24 (15/16") December 2008 / 509 5/6 www.sensortechnics.com CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media ELECTROMAGNETIC CAPABILITY8 Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A
CTEM9350GF0
物料型号: - CTE9000/CTU9000系列,是为工业介质设计的OEM压力变送器。

器件简介: - 这些变送器可以测量0到35 bar或0到500 psi的压力,提供多种输出选项,包括0到10V、0.5到4.5V、0到5V、1到6V或4到20mA。它们适用于工业用途,采用全焊接不锈钢膜片结构。

引脚分配: - 1号引脚:+Vs(0到10V输出) - 2号引脚:Vout(输出电压) - 3号引脚:case(接地) - 4号引脚:-Vs(0到10V输出)

参数特性: - 工作温度范围为-40到100°C,补偿温度范围为0到70°C。 - 压力范围从0到35 bar或0到500 psi不等,具体取决于型号。 - 供电电压(反极性保护):9到32V。 - 负载电流(源):1mA。 - 湿度限制:0到98%RH。 - 振动(5到500 Hz):10 gRMS。 - 机械冲击:50 g。 - 校验压力和爆破压力根据不同型号有所不同。

功能详解: - 变送器提供多种输出选项,能够根据压力变化输出相应的电压或电流信号。它还具有长期稳定性和重复性,输出噪声低,响应时间短。

应用信息: - 适用于工业介质的压力测量,具体应用场景包括但不限于过程控制、化工、石油和天然气等领域。

封装信息: - 变送器的质量为82克,具体尺寸图在文档中有详细描述。变送器的封装包括不同的压力接口,如1/8"BSPT、1/4"BSPT、3/8" BSPT等,材质为黄铜或镍镀。
CTEM9350GF0 价格&库存

很抱歉,暂时无法提供与“CTEM9350GF0”相匹配的价格&库存,您可以联系我们找货

免费人工找货