0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CTU8P01AD0

CTU8P01AD0

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    CTU8P01AD0 - OEM pressure transmitters for industrial media - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
CTU8P01AD0 数据手册
CTE8000 / CTU8000 Series OEM pressure transmitters for industrial media FEATURES · 0...-1 to 0...100 bar, 0...-15 to 0...1500 psi gage1 or absolute10 · For many industrial gases and liquids · 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output · Field interchangeable · For industrial use MEDIA COMPATIBILITY Wetted materials: stainless steel 1.4404 (316L), ceramic AL2O3, NBR9 Housing: stainless steel,protection class IP 64 (according to DIN EN 60529) respectively NEMA 4X1 SPECIFICATIONS11,12 Maximum ratings Supply voltage (reverse polarity protection) 12...30 V CTx8...0 9...30 V CTx8...1, ...6, ...7 9...30 V CTx8...42 Maximum load current (source) CTx8...0, ...1, ...6, ...7 Temperature limits Storage Operating8 Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure 3 ELECTRICAL CONNECTION 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output +Vs 1 Vout 2 -Vs 4 case 3 V 12 (9) to 30 V sensor 1 mA GND -55 to 100°C -40 to 100°C 0 to 70°C 0 - 98 %RH 10 gRMS 50 g 2 x rated pressure 4...20 mA output +Vs 1 N/C 2 -Vs 4 case 3 9 to 30 V sensor V RL GND December 2008 / 508 1/6 www.sensortechnics.com CTE8000 / CTU8000 Series OEM pressure transmitters for industrial media COMMON PERFORMANCE CHARACTERISTICS Characteristics Operating pressure CTE8001... CTE8N01... CTE8P01... CTE8002... CTE8005... CTE8010... CTE8016... CTE8020... CTE8025... CTE8035... CTE8050... CTE8070... CTE8100... CTU8015... CTU8N15... CTU8P15... CTU8030... CTU8100... CTU8200... CTU8300... CTU8500... CTU8700... CTU81K0... CTU81K5... Offset Span Offset Span Min. 0 -1 -1 0 0 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 0 0 0 Typ. Max. 1 +1 0 2 5 10 16 20 25 35 50 70 100 15 +15 0 30 100 200 300 500 700 1000 1500 Unit bar p si Thermal effectss (0 to 70°C)4 Thermal effects (-40 to 0°C, 70 to 100°C) 0.02 0.02 0.03 0.03 ±0.1 ±0.3 ±0.04 1 0.05 0.05 %FSO/°C Non-linearity, hysteresis (BSL) and repeatability5 Long term stability6 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection Offset Span CTx8...4 all others CTx8...4 all others ±0.3 %FSO 5 ms 0.05 0.002 0.08 0.002 %FSO/V December 2008 / 508 2/6 www.sensortechnics.com CTE8000 / CTU8000 Series OEM pressure transmitters for industrial media INDIVIDUAL PERFORMANCE CHARACTERISTICS 0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. CT...8N... all others CT...8N... all others 4.9 9.9 4.9 Typ. 5 0.03 5 10 3 Max. 5.1 0.1 5.1 10.1 25 5 Unit V Output impedance Current consumption (no load) Ω mA 0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...8N... all others CT...8N... all others Min. 2.45 0.45 1.95 3.95 Typ. 2.5 0.5 2 4 3 Max. 2.55 0.55 2.05 4.05 25 5 Unit V Ω mA 0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) CT...8N... all others CT...8N... all others Min. 2.45 2.45 4.95 Typ. 2.5 0.03 2.5 5.0 3 Max. 2.55 0.08 2.55 5.05 25 5 Unit V Ω mA 1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. CT...8N... all others CT...8N... all others 3.45 0.95 2.45 4.95 Typ. 3.5 1 2.5 5.0 3 Max. 3.55 1.05 2.55 5.05 25 5 Unit V Output impedance Current consumption (no load) Ω mA 4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. CT...8N... all others CT...8N... all others 11.9 3.9 7.9 15.9 Typ. 12.0 4.0 8.0 16.0 250 Max. 12.1 4.1 8.1 16.1 Unit mA Power consumption (IL = 20 mA) December 2008 / 508 mW 3/6 www.sensortechnics.com CTE8000 / CTU8000 Series OEM pressure transmitters for industrial media Specification notes: 1. IP 64 protection is given when the connector is locked. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Tests are in accordance with EN61000-6-2, April 1999. 9. Other material on special request. When using devices with optional nickel plated fittings, consider the media compatibility of the fittings also. 10. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. 11. CE-labelling is in accordance with 89/336/EEC. 12. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. OUTLINE DRAWING NOM 72 (2.83) 6.5 (0.26) 52 (2.05) 4 vent hole¹ 21.8 (0.86) diam. G 1/8" (BSP) 1 3 M12 x 1 connector 2 Detail A Detail A Output 4.0 (0.16) diam. Pin 1 2 3 4 0...10 V 0.5...4.5 V 0...5 V, 1...6 V +VS Vout case -Vs 4...20 mA +VS NC case -Vs o-ring grove for o-ring 11.8 x 1.8 (0.456 x 0.071) (ZA004029) mass: 72 g dimensions in mm (inches) December 2008 / 508 4/6 www.sensortechnics.com CTE8000 / CTU8000 Series OEM pressure transmitters for industrial media RECOMMENDED ACCESSORY (not included in delivery) ZK000101: ZP000112-B: Connector/cable assembly (different cable lenghts available) Mating Connector (without cable) NOM 2 m (other cable lenghts on request) PIN CONNECTION Pin Flying lead end Brown Green White and shield Yellow NOM 60 Shield 1 2 3 36.5 4 Vent tube M12x1 Ø 20 Note: For proper function of all gage devices the vent tube must have access to the ambient atmosphere. dimensions in mm OPTIONAL PRESSURE FITTINGS (brass, nickel plated) Male fittings A B C LOAD LIMITATION 4...20 mA output version 1400 Ohm 1200 D 1000 800 op e ra ratin ng g e 600 Female fittings E G F H 400 200 0 5 9 16 20 25 30 V supply voltage Dimensions in mm (inches) A 1/8" BSPT 1/4" BSPT 3/8" BSPT 1/2" BSPT 1/8" BSP 1/4" BSP 3/8" BSP 1/8" NPT 1/4" NPT B 8 (0.315) 12 (0.472) 11.5 (0.453) 16 (0.630) 12.5 (0.492) 8.5 (0.335) 12.5 (0.492) 10 (0.394) 14 (0.551) C 13 (0.512) 5.5 (0.217) 5 (0.197) 7 (0.276) 11 (0.433) 5 (0.197) 7 (0.276) 13 (0.512) 6 (0.236) D (Hex.) 14 (9/16") 14 (9/18") 17 (11/16") 22 (7/8") 14 (9/16") 19 (3/4") 22 (7/8") 17 (11/16") 22 (7/8") E 1/8" BSP 1/4" BSP 3/8" BSP 1/2" BSP Dimensions in mm (inches) F 5 (0.197) 7 (0.276) 6 (0.236) 18 (0.707) G 15 (0.591) 20 (0.787) 20 (0.787) 23 (0.906) H (Hex.) 14 (9/16") 17 (11/16") 22 (7/8") 24 (15/16") December 2008 / 508 5/6 www.sensortechnics.com CTE8000 / CTU8000 Series OEM pressure transmitters for industrial media ELECTROMAGNETIC CAPABILITY8 Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A
CTU8P01AD0 价格&库存

很抱歉,暂时无法提供与“CTU8P01AD0”相匹配的价格&库存,您可以联系我们找货

免费人工找货