0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
KTE3001AQ7

KTE3001AQ7

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    KTE3001AQ7 - OEM pressure transmitters for industrial media - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
KTE3001AQ7 数据手册
KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media FEATURES · 0...-1 to 0...50 bar, 0...-15 to 0...750 psi gage1 or absolute · For many industrial gases and liquids · 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output · Field interchangeable · For industrial use MEDIA COMPATIBILITY Wetted materials: PPS, ceramic Al2O3 and NBR8 Housing: stainless steel 1.4404 (316L), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1 SPECIFICATIONS10,11 Maximum ratings ELECTRICAL CONNECTION 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output Supply voltage (reverse polarity protection) KTx3...0 13...32 V KTx3...6 9...32 V KTx3...1, ...7 8...32 V KTx3...42 7...32 V Maximum load current Source/Sink Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure3 +Vs 1 Vout 3 -Vs 2 13 (8, 9)...32 V Sensor V GND Internal connection (do not connect) 1 mA -40...100°C -25...85°C 0...70°C 0 - 95 %RH 10 gRMS 50 g 2 x rated pressure 4... 20 mA output Sensor +Vs 1 N/C 3 -Vs 2 7...32 V V RL GND Internal connection (do not connect) December 2008 / 626 1/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media COMMON PERFORMANCE CHARACTERISTICS (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure KTE3001... KTE3N01G... KTE3P01G... KTE3002... KTE3005... KTE3010... KTE3016... KTE3020... KTE3025... KTE3035... KTE3050... KTU3015... KTU3N15G... KTU3P15G... KTU3030... KTU3050... KTU3100... KTU3200... KTU3300... KTU3500... KTU3750... Offset Span Offset Span Min. 0 -1 -1 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 0 0 Typ. Max. 1 1 0 2 5 10 16 20 25 35 50 15 15 0 30 50 100 200 300 500 750 0.05 0.05 Unit bar p si Thermal effects (0...70°C)4 Thermal effects (-25...0°C, 70...85°C) Long term stability 6 0.02 0.02 0.03 0.03 ±0.1 ±0.3 ±0.04 1 0.005 %FSO/°C Non-linearity, hysteresis (BSL) and repeatability5 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection ±0.3 %FSO 5 ms %FSO/V Specification notes: IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Non-linearity refers to the B est S traight L ine fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Other sealing materials are available on request. 9. Test are in accordance with EN61000-6-2, April 1999. 10. CE-labelling is in accordance with 89/336/EEC. 11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 1. December 2008 / 626 2/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media INDIVIDUAL PERFORMANCE CHARACTERISTICS 0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. KT...3N... all others KT...3N... all others 4.9 9.9 4.9 Typ. 5 0.03 5 10 3 Max. 5.1 0.1 5.1 10.1 25 5 Unit V Output impedance Current consumption (no load) Ω mA 0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) KT...3N... all others KT...3N... all others Min. 2.45 0.45 1.95 3.95 Typ. 2.5 0.5 2 4 3 Max. 2.55 0.55 2.05 4.05 25 5 Unit V Ω mA 0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 Output impedance Current consumption (no load) KT...3N... all others KT...3N... all others Min. 2.45 2.45 4.95 Typ. 2.5 0.03 2.5 5.0 3 Max. 2.55 0.08 2.55 5.05 25 5 Unit V Ω mA 1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. KT...3N... all others KT...3N... all others 3.45 0.95 2.45 4.95 Typ. 3.5 1 2.5 5.0 3 Max. 3.55 1.05 2.55 5.05 25 5 Unit V Output impedance Current consumption (no load) Ω mA 4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Zero pressure offset Full scale span 7 Min. KT...3N... all others KT...3N... all others 11.9 3.9 7.9 15.9 Typ. 12.0 4.0 8.0 16.0 250 Max. 12.1 4.1 8.1 16.1 Unit mA Power consumption (IL = 20 mA) December 2008 / 626 mW 3/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media OUTPUT CHARACTERISTICS 0...10 V output version 10 Vout V9 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure KTx3P... all other KTx3N... 0.5...4.5 V output version 10 Vout 9 V 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure KTx3P... all other KTx3N... 0...5 V output version 10 Vout V9 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure all other KTx3P... KTx3N... 1...6 V output version 10 Vout V9 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure all other KTx3P... KTx3N... 4...20 mA output version 20 Iout 18 mA 16 14 12 KTx3P... 10 8 6 4 2 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure all other KTx3N... December 2008 / 626 4/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media OUTLINE DRAWING 4.5 (0.18) 12 (0.47) NOM 68 (2.86) 8.5 (0.33) 3 G1/4" (1/4" BSP) 27.0 (1.06) diam. 30 (1.18) 2 1 12 (0.47) vent hole mass: 210 g dimensions in mm (inches) LOAD LIMITATION 4...20 mA output version 1400 Ohm 1200 1000 800 RECOMMENDED ACCESSORY Plug DIN EN 175301-803 A and profile washer included in delivery. For a complete connector/cable assembly use order no. ZK000110-x (x=cable lenghts in m). 50 34 op e ra ratin ng g e 600 400 200 0 5 7 10 16 Profile washer M3 31 dimensions in mm 20 25 30 32 V supply voltage Note: For proper function of all gage devices the gage port must be vented to the atmosphere through the connector/cable assembly. December 2008 / 626 5/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media ELECTROMAGNETIC CAPABILITY9 Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A
KTE3001AQ7 价格&库存

很抱歉,暂时无法提供与“KTE3001AQ7”相匹配的价格&库存,您可以联系我们找货

免费人工找货