KTEM2100G4C5S

KTEM2100G4C5S

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    KTEM2100G4C5S - OEM submersible level sensors - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
KTEM2100G4C5S 数据手册
KTE2000...CS Series OEM submersible level sensors FEATURES · 0...50 to 0...200 mbar (approx. 0...1.67 to 0...6.70 ft H2O) · Capacitive ceramic pressure cells · For corrosive media · 4...20 mA output · High overpressure resistance MEDIA COMPATIBILITY Wetted materials: Ceramic Al2O3, stainless steel 1Cr18Ni9Ti, NBR, Viton, PE (PUR) Housing: protection class IP 68 (according to DIN EN 60529) respectively NEMA 6P1 SPECIFICATIONS6 Maximum ratings Supply voltage2 Temperature limits Storage Operating Compensated Proof pressure3 12...30 V ELECTRICAL CONNECTION -30...85 °C -30...80 °C -30...70 °C 10 x rated pressure +Vs Black Sensor -Vs Red 12...30 V V RL GND October 2008 / 653 1/3 www.sensortechnics.com KTE2000...CS Series OEM submersible level sensors INDIVIDUAL PERFORMANCE CHARACTERISTICS Characteristics Operating pressure KTEM2050... KTEM2100... KTEM2200... Min. 0 0 0 Typ. Max. 50 100 200 Unit mbar Zero pressure offset Full scale span Thermal effects4 Accuracy5 Long term stability Vibration (200 Hz/g) -20...70 °C -20...-30 °C 4.0 16.0 ±0.015 ±0.02 ±0.75 ±0.1 ±0.01 mA %FSO/°C %FSO %FSO/year %FSO LOAD LIMITATION2 Rmax = Vs − 12 V 0.02 A Specification notes: 1. 2. 3. 4. 5. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting cable. Thus the vent tube of the cable end must have access to the ambient pressure. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. All specifications shown are relative to 25°C. Accuracy is the combined error from offset and span calibration, linearity, hysteresis and repeatability. Linearity is the measured deviation based on a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration errors include the deviation of offset and full scale from nominal values. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 6. October 2008 / 653 2/3 www.sensortechnics.com KTE2000...CS Series OEM submersible level sensors OUTLINE DRAWING 79.0 56.0 10.0 5 m cable incl. in delivery (other cable lengths on request) Ø 42.0 Vent tube dimensions in mm ORDERING INFORMATION KTEM2 xxx G 4 C5S Cable submersible 5: 5 m cable length (other cable lengths on request) output signal 4: 4...20 mA Pressure range 050: 0...50 mbar (approx. 1.67 ft H2O) 100: 0...100 mbar (approx. 3.35 ft H2O) 200: 0...200 mbar (approx. 6.70 ft H2O) Pressure mode G: gage pressure Note: Other pressure ranges and calibrations (e.g. psi, inch H2O, cm H2O) are available on request. Please contact your nearest Sensortechnics sales representative. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. October 2008 / 653 3/3 www.sensortechnics.com
KTEM2100G4C5S 价格&库存

很抱歉,暂时无法提供与“KTEM2100G4C5S”相匹配的价格&库存,您可以联系我们找货

免费人工找货