KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
FEATURES · 0...-1 to 0...50 bar, 0...-15 to 0...750 psi gage1 or absolute · For many industrial gases and liquids · 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output · Field interchangeable · For industrial use MEDIA COMPATIBILITY
Wetted materials: PPS, ceramic Al2O3 and NBR8 Housing: stainless steel 1.4404 (316L), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1
SPECIFICATIONS10,11
Maximum ratings
ELECTRICAL CONNECTION
0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output
Supply voltage (reverse polarity protection) KTx3...0 13...32 V KTx3...6 9...32 V KTx3...1, ...7 8...32 V KTx3...42 7...32 V Maximum load current Source/Sink Temperature limits Storage Operating Compensated Humidity limits Vibration (5 to 500 Hz) Mechanical shock Proof pressure3
+Vs 1 Vout 3 -Vs 2
13 (8, 9)...32 V
Sensor
V
GND Internal connection (do not connect)
1 mA
-40...100°C -25...85°C 0...70°C 0 - 95 %RH 10 gRMS 50 g 2 x rated pressure
4... 20 mA output
Sensor
+Vs 1 N/C 3 -Vs 2
7...32 V
V
RL GND
Internal connection (do not connect)
December 2008 / 626
1/6
www.sensortechnics.com
KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
COMMON PERFORMANCE CHARACTERISTICS
(VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Operating pressure KTE3001... KTE3N01G... KTE3P01G... KTE3002... KTE3005... KTE3010... KTE3016... KTE3020... KTE3025... KTE3035... KTE3050... KTU3015... KTU3N15G... KTU3P15G... KTU3030... KTU3050... KTU3100... KTU3200... KTU3300... KTU3500... KTU3750... Offset Span Offset Span
Min.
0 -1 -1 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 0 0
Typ.
Max.
1 1 0 2 5 10 16 20 25 35 50 15 15 0 30 50 100 200 300 500 750 0.05 0.05
Unit
bar
p si
Thermal effects (0...70°C)4 Thermal effects (-25...0°C, 70...85°C) Long term stability
6
0.02 0.02 0.03 0.03 ±0.1 ±0.3 ±0.04 1 0.005
%FSO/°C
Non-linearity, hysteresis (BSL) and repeatability5 Output noise (0 < f < 1 kHz) Response time (10 to 90 %) Power supply rejection
±0.3 %FSO 5 ms %FSO/V
Specification notes:
IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Non-linearity refers to the B est S traight L ine fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Other sealing materials are available on request. 9. Test are in accordance with EN61000-6-2, April 1999. 10. CE-labelling is in accordance with 89/336/EEC. 11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. 1.
December 2008 / 626
2/6
www.sensortechnics.com
KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
INDIVIDUAL PERFORMANCE CHARACTERISTICS
0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span
7
Min.
KT...3N... all others KT...3N... all others 4.9 9.9 4.9
Typ.
5 0.03 5 10 3
Max.
5.1 0.1 5.1 10.1 25 5
Unit
V
Output impedance Current consumption (no load)
Ω mA
0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) KT...3N... all others KT...3N... all others
Min.
2.45 0.45 1.95 3.95
Typ.
2.5 0.5 2 4 3
Max.
2.55 0.55 2.05 4.05 25 5
Unit
V
Ω mA
0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span7 Output impedance Current consumption (no load) KT...3N... all others KT...3N... all others
Min.
2.45 2.45 4.95
Typ.
2.5 0.03 2.5 5.0 3
Max.
2.55 0.08 2.55 5.05 25 5
Unit
V
Ω mA
1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span
7
Min.
KT...3N... all others KT...3N... all others 3.45 0.95 2.45 4.95
Typ.
3.5 1 2.5 5.0 3
Max.
3.55 1.05 2.55 5.05 25 5
Unit
V
Output impedance Current consumption (no load)
Ω mA
4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C)
Characteristics
Zero pressure offset Full scale span
7
Min.
KT...3N... all others KT...3N... all others 11.9 3.9 7.9 15.9
Typ.
12.0 4.0 8.0 16.0 250
Max.
12.1 4.1 8.1 16.1
Unit
mA
Power consumption (IL = 20 mA)
December 2008 / 626
mW
3/6
www.sensortechnics.com
KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
OUTPUT CHARACTERISTICS
0...10 V output version
10 Vout V9 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure KTx3P... all other KTx3N...
0.5...4.5 V output version
10 Vout 9 V 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure KTx3P... all other KTx3N...
0...5 V output version
10 Vout V9 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure all other KTx3P... KTx3N...
1...6 V output version
10 Vout V9 8 7 6 5 4 3 2 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure all other KTx3P... KTx3N...
4...20 mA output version
20 Iout 18 mA 16 14 12 KTx3P... 10 8 6 4 2 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure all other KTx3N...
December 2008 / 626
4/6
www.sensortechnics.com
KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
OUTLINE DRAWING
4.5 (0.18) 12 (0.47) NOM 68 (2.86) 8.5 (0.33) 3 G1/4" (1/4" BSP) 27.0 (1.06) diam. 30 (1.18) 2 1 12 (0.47)
vent hole
mass: 210 g
dimensions in mm (inches)
LOAD LIMITATION
4...20 mA output version
1400 Ohm 1200 1000 800
RECOMMENDED ACCESSORY
Plug DIN EN 175301-803 A and profile washer included in delivery. For a complete connector/cable assembly use order no. ZK000110-x (x=cable lenghts in m).
50
34
op e ra ratin ng g e
600 400 200 0 5 7 10 16
Profile washer M3 31
dimensions in mm
20 25 30 32 V supply voltage
Note: For proper function of all gage devices the gage port must be vented to the atmosphere through the connector/cable assembly.
December 2008 / 626
5/6
www.sensortechnics.com
KTE3000 / KTU3000 Series
OEM pressure transmitters for industrial media
ELECTROMAGNETIC CAPABILITY9
Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A