RCOB001DP

RCOB001DP

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    RCOB001DP - Precision compensated pressure sensors - Sensortechnics GmbH

  • 数据手册
  • 价格&库存
RCOB001DP 数据手册
RCO Series Precision compensated pressure sensors FEATURES · 0...50 mbar to 0...10 bar, 0...1 to 0...150 psi, differential, gage or absolute · Temperature compensated · Calibrated zero and span · High impedance for low power applications · Sensortechnics PRO services MEDIA COMPATIBILITY To be used with non-corrosive, non-ionic working fluids such as clean dry air, dry gases and the like. SPECIFICATIONS Maximum ratings Supply voltage VS Lead temperature (soldering 4 sec.) Temperature ranges Compensated Operating Storage Humidity limits (non-condensing) Common mode pressure +20 VDC 250 °C EQUIVALENT CIRCUIT 2 1 0 to 70 °C -40 to 85 °C -55 to 125 °C 0 to 100% RH 3 5 6 50 psig 4 E / 11712 / A 1/5 www.sensortechnics.com RCO Series Precision compensated pressure sensors PRESSURE RANGES SPECIFICATIONS1 RCO...P (Prime Grade) devices Part number RCOM050...P RCOM100...P RCOM250...P RCOB001...P RCOB002...P RCOB005...P RCOB010...P RCOP001...P RCOP005...P RCOP015...P RCOP030...P RCOP100...P RCOP150...P Operating pressure 0...50 mbar 0...100 mbar 0...250 mbar 0...1 bar 0...2 bar 0...5 bar 0...10 bar 0...1 psi 0...5 psi 0...15 psi 0...30 psi 0...100 psi 0...150 psi Proof pressure2 1.4 bar 1.4 bar 1.4 bar 2.1 bar 4.2 bar 10 bar 10 bar 2 0 p si 2 0 p si 3 0 p si 6 0 p si 1 5 0 p si 1 5 0 p si Full-scale span3 Min. Typ. Max. 12.92 mV 25.84 mV 43.1 mV 86.2 mV 86.2 mV 71.8 mV 86.0 mV 17.82 mV 59.40 mV 89.10 mV 89.10 mV 99.00 mV 89.00 mV 13.05 mV 26.10 mV 43.5 mV 87.0 mV 87.0 mV 72.5 mV 87.0 mV 18.0 mV 60.0 mV 90.0 mV 90.0 mV 100.0 mV 90.0 mV 13.18 mV 26.37 mV 43.9 mV 87.9 mV 87.9 mV 73.2 mV 88.0 mV 18.18 mV 60.60 mV 90.90 mV 90.90 mV 101.0 mV 91.0 mV RCO...H (High Grade) devices Part number RCOM050...H RCOM100...H RCOM250...H RCOB001...H RCOB002...H RCOB005...H RCOB010...H RCOP001...H RCOP005...H RCOP015...H RCOP030...H RCOP100...H RCOP150...H Operating pressure 0...50 mbar 0...100 mbar 0...250 mbar 0...1 bar 0...2 bar 0...5 bar 0...10 bar 0...1 psi 0...5 psi 0...15 psi 0...30 psi 0...100 psi 0...150 psi Proof pressure2 1.4 bar 1.4 bar 1.4 bar 2.1 bar 4.2 bar 10 bar 10 bar 2 0 p si 2 0 p si 3 0 p si 6 0 p si 1 5 0 p si 1 5 0 p si Full-scale span3 Min. Typ. Max. 12.3 mV 24.6 mV 41.7 mV 82.2 mV 82.2 mV 68.9 mV 82.2 mV 17 mV 57.5 mV 85 mV 85 mV 95 mV 85 mV 13.05 mV 26.1 mV 43.5 mV 87.0 mV 87.0 mV 72.5 mV 87.0 mV 18 mV 60 mV 90 mV 90 mV 100 mV 90 mV 13.8 mV 27.6 mV 45.3 mV 91.9 mV 91.9 mV 76.1 mV 91.9 mV 19 mV 62.5 mV 95 mV 95 mV 105 mV 95 mV E / 11712 / A 2/5 www.sensortechnics.com RCO Series Precision compensated pressure sensors PERFORMANCE CHARACTERISTICS1 RCO...P (Prime Grade) devices Characteristics Zero pressure offset Combined linearity and hysteresis4 Temperature effects (0 to 70°C)5 Repeatability6 Input impedance7 Output impedance8 Common mode voltage9 Response time Long term stability of offset and span11 10 Min. -0.25 -0.50 Typ. 0 0 ±0.1 ±0.1 ±0.2 ±0.2 4.0 4.0 6.0 100 ±0.1 Max. +0.25 +0.50 ±0.5 ±0.5 ±1.0 ±0.5 Unit mV %FSO mV %FSO kΩ all RCO...DP devices all RCO...AP devices12 Offset Span 5.8 6.2 V DC µ se c mV RCO...H (High Grade) devices Characteristics Zero pressure offset Combined linearity and hysteresis4 Temperature effects (0 to 70°C)5 Repeatability6 Input impedance7 Output impedance8 Common mode voltage9 Response time10 Long term stability of offset and span11 5.7 all RCO...DH devices all RCO...AH devices12 Offset Span Min. -0.50 -1.00 Typ. 0 0 ±0.2 ±0.2 ±0.4 ±0.2 4.0 4.0 6.0 100 ±0.1 Max. +0.50 +1.00 ±1.0 ±1.0 ±2.0 ±0.5 Unit mV %FSO mV %FSO kΩ 6.3 V DC µ se c mV Specification notes: 1. 2. 3. 4. 5. 6. Reference conditions: VS = 12 V, TA = 25°C, common-mode line pressure = 0 barg, pressure applied to Port B. For absolute devices only, pressure is applied to Port A and the output polarity is reversed. Maximum pressure above which causes permanent sensor failure. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is ratiometric to the supply voltage. Hysteresis - the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Maximum error band of the offset voltage and the error band of the span, relative to the 25°C reading. Maximum difference in output at any pressure within the operating pressure range and temperature within 0°C to +70°C after: a) 1,000 temperature cycles, 0°C to +70°C b) 1.5 million pressure cycles, 0 psi to full-scale span Input impedance is the impedance between pins 2 and 4. Output impedance is the impedance between pins 3 and 5. This is the common-mode voltage of the output arms (pins 3 and 5) for VS = 12 VDC. Response time for a 0 bar to full-scale span pressure step change, 10 % to 90 % rise time. Long term stability over a one year period. Absolute devices with improved zero pressure offset values are available on request. Please contact your nearest Sensortechnics sales office for further information. 3/5 7. 8. 9. 10. 11. 12. E / 11712 / A www.sensortechnics.com RCO Series Precision compensated pressure sensors PHYSICAL DIMENSIONS 1.10 ref (27.9 ref 0.85 (21.6) 0.80 (20.3) 1.03 ref (26.2) ref 0.55 (14.0) 0.36 (9.1) 1.08 (27.4) 0.41 (10.4) Ø 0.14 (3.6) thru rivet mounting holes 0.25 (6.4) 0.020 (0.51) x 0.01 (0.25) pins 6 pls Ø 0.08 (2.0) pressure port B 0.05 (1.3) 0.190 (4.8) 2 pls 123456 Port B: High pressure Port for gage and differential devices Port A: High pressure Port for absolute devices 0.42 (10.7) R0.13 (R3.3) typ 0.20 (5.1) 0.10 (2.5) pin spacing mass: 5 g Ø 0.08 (2.0) pressure port A 0.05 (1.3) third angle projection dimensions in inches (mm) ELECTRICAL CONNECTION 6 5 4 3 2 1 Pin 1 marked by dot Temperature output (-) Output (-) GND Output (+) +Vs Temperature output (+) Note: The polarity indicated is for pressure applied to port B. For absolute devices pressure is applied to port A and the output polarity is reversed. E / 11712 / A 4/5 www.sensortechnics.com RCO Series Precision compensated pressure sensors ORDERING INFORMATION - AVAILABLE LISTINGS Note: · Preferred listings are highlighted in grey · RCO...P = Prime Grade, RCO...H = High Grade Pressure range 50 mbar 100 mbar 250 mbar 1 bar 2 bar 5 bar 10 bar 1 p si 5 p si 1 5 p si 3 0 p si 1 0 0 p si 1 5 0 p si Pressure mode Absolute Differential/Gage RCOM050D(P,H) RCOM100D(P,H) RCOM250D(P,H) RCOB001A(P,H) RCOB002A(P,H) RCOB005A(P,H) RCOB001DP RCOB002D(P,H) RCOB005D(P,H) RCOB010D(P,H) RCOP001D(P,H) RCOP005D(P,H) RCOP015A(P,H) RCOP030A(P,H) RCOP100A(P,H) RCOP150A2P RCOP015DP RCOP030D(P,H) RCOP100D(P,H) RCOP150D(P,H) Sensortechnics PRO services: · Extended guarantee period of 2 years · Improved performance characteristics · Custom product modifications and adaptations even for small quantities · Advanced logistics models for supply inventory and short delivery times · Technical support through application engineers on the phone or at your site · Fastest possible technical response for design and QA engineers ... plus other services on request Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. E / 11712 / A 5/5 www.sensortechnics.com
RCOB001DP 价格&库存

很抱歉,暂时无法提供与“RCOB001DP”相匹配的价格&库存,您可以联系我们找货

免费人工找货