SCC05D

SCC05D

  • 厂商:

    SENSORTECHNICS

  • 封装:

  • 描述:

    SCC05D - Pressure sensors - Sensortechnics GmbH

  • 详情介绍
  • 数据手册
  • 价格&库存
SCC05D 数据手册
SCC Series Pressure sensors FEATURES · · · 0...5 to 0...100 psi Low cost sensor element Internal temperature compensation Differential, gage and absolute GENERAL DESCRIPTION The SCC series offer an extremely low cost sensor element with a temperature stable output when driven with a constant current source. These integrated circuit sensors were designed for extremely cost sensitive applications where precise accuracy over a wide temperature range is not required. This series is intended for use with non-corrosive, non-ionic working fluids such as air and dry gases. Absolute devices have an internal vacuum reference and an output voltage proportional to applied pressure. The differential devices allow application of pressure to either side of the diaphragm and the devices are thereby available to measure both differential and/or gage pressures. This product is packaged either in SenSym's standard low cost chip carrier "button" package, a plastic ported "N" package or a dual inline package (DIP). All packages are designed for applications where the sensing element is to be integral to the OEM equipment. These packages can be o-ring · APPLICATIONS · · · · · Pneumatic controls Automotive diagnostics Medical equipment Dental equipment Environmental controls Scale: 1 cm ½ inch sealed, epoxied, and/or clamped onto a pressure fitting. A closed bridge 4-pin SIP configuration is provided for electrical connection to the button package. The DIP package offer a 5-pin open bridge configuration. EQUIVALENT CIRCUIT Vs ELECTRICAL CONNECTION + Output GND out + +VS out - 1 2 3 4 P1 Button Sensor or "N" Package +Vs P2 1 out + GND +Vs 4 out vent hole out GND out + SCC.. button sensor 1 P1 4 +Vs out + GND 1 P1 P2 4 +Vs Vs +Vs out - +Vs Output SCCxxxGD2 DIP SCCxxxAD2 DIP SCCxxxD4 DIP + DIP Package The polarity indicated is for pressure applied to SCC.../SCC...N : P1 (forward gage) SCC...GD2 : P2 (backward gage) SCC...ASO/GSO : P1 (forward gage) SCC...AD2 : P1 (forward gage) SCC...DD4 : P2 (backward gage) July 2005 / 040 1/5 www.sensortechnics.com SCC Series Pressure sensors PRESSURE SENSOR CHARACTERISTICS Maximum ratings (for all devices) Supply current, IS Temperature ranges Compensated Operating Storage 1.5 mA 0 to +50°C -40 to +85°C -55 to +125°C Humidity Lead temperature (soldering 4 sec.) Common-mode pressure 0 to 100 %RH 250°C 150 psi PERFORMANCE CHARACTERISTICS (individual models) IS = 1.0 mA, TA = 25°C1 Operating pressure range 0 - 5 psid(g) 0 - 15 psia 0 - 15 psid(g) 0 - 30 psia 0 - 30 psid(g) 0 - 100 psia 0 - 100 psid(g) Part number SCC05(D,G) SCC15A SCC15(D,G) SCC30A SCC30(D,G) SCC100A SCC100(D,G) Proof pressure9 20 psi 30 psia 30 psi 60 psia 60 psi 150 psia 150 psi Accuracy2 0.50 0.50 0.50 0.50 0.50 0.50 0.50 % % % % % % % Effect on span3 (0 - 50°C) 1.50 1.50 1.50 1.50 1.50 1.50 1.50 % % % % % % % Effect on offset4 (0 - 50°C) 2.00 2.00 2.00 2.00 2.00 2.00 2.00 % % % % % % % Full-scale span1,5 (mV) 25 - 65 30 - 95 40 - 95 60 - 150 60 - 150 85 - 225 85 - 225 PERFORMANCE CHARACTERISTICS (all models) IS = 1.0 mA, TA = 25°C Characteristics Zero pressure offset Combined linearity, hysteresis, repeatability2 Temperature effect on span3,8 Temperature effect on offset4,8 Long term stability of offset and span6 Response time (10 to 90 %)7 Input impedance Output impedance Min. -30.0 ----------4.00 4.00 Typ. -10 0.25 0.25 0.50 0.10 0.10 5.00 5.00 Max. 20.0 0.50 1.50 2.00 ----6.50 6.50 Unit mV %FSO %FSO %FSO mV ms kΩ kΩ Specification notes: 1. 2. Reference conditions: supply current = 1.0 mA, TA=25°C, common-mode line pressure = 0 psig, pressure applied to P1, unless otherwise noted. Accuracy is the sum of hysteresis and linearity. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Linearity refers to the best straight line fit as measured for the offset, full-scale and 1/2 full-scale pressure at 25°C. This is the maximum temperature shift for span when measured between 0 and 50°C relative to the 25°C reading. Typical temperature coefficients for span and resistance are -2200 and +2200 ppm/°C respectively. This is the maximum temperature shift for offset when measured between 0 and 50°C relative to the 25°C reading. Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Maximum difference in output at any pressure with the operating pressure range and temperature within 0 to 50°C after: a) 100 temperature cycles, 0 to 50°C. b) 1.0 million pressure cycles, 0 psi to full-scale span. Response time for a 0 psi to full-scale span pressure step change. 10 to 90 % rise time. Temp. effect on span and offset are guaranteed by design. Therefore these parameters are not 100 % tested. If the proof pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture. Note: The proof pressure for the forward gage of all devices in the D4-package is the specified value or 100 psi whatever is less. The SCC100D (button package) can be used in forward gage mode only when the pressure doesn't exceed 30 psi, or no special care ist taken. 3. 4. 5. 6. 7. 8. 9. 2/5 July 2005 / 040 www.sensortechnics.com SCC Series Pressure sensors PHYSICAL DIMENSIONS Button package mass: 1 g dimensions in inches (mm) Basic sensor DIP "D2" package mass: 1 g dimensions in inches (mm) July 2005 / 040 3/5 www.sensortechnics.com SCC Series Pressure sensors PHYSICAL DIMENSIONS (cont.) Basic sensor DIP "D4" package 0.550 (13.97) P1 P2 0.050 typ. (1.27) 0.470 (11.94) 0.135 (3.43) 0.250 (6.35) 0.090 typ. (2.29) 0.300 (7.62) 0.285 (7.24) 0.380 (9.65) 0.070 (1.78) 0.600 (15.24) 0.01 (0.25) 0.110 typ. (2.79) 0.020 typ. (0.51) 0.100 typ. (2.54) mass: 1 g dimensions in inches (mm) N package mass: 5 g dimensions in inches (mm) 4/5 July 2005 / 040 www.sensortechnics.com SCC Series Pressure sensors ORDERING INFORMATION Part number Pressure range Button p ackag e S C C 15A S C C 30A S C C 100A " N " p ackag e S C C 15A N S C C 30A N S C C 100A N DIP package single port S C C 15A D 2 S C C 30A D 2 S C C 100A D 2 SCC05GD2 use differential devices use differential devices SCC15GD2 SCC30GD2 SCC100GD2 S C C 05D S C C 15D S C C 30D S C C 100D S C C 05D N S C C 15D N S C C 30D N S C C 100D N S C C 05D D 4 S C C 15D D 4 S C C 30D D 4 S C C 100D D 4 DIP package dual port 0...15 psi Absolute pressure 0...30 psi 0...100 psi 0...5 psi Gage pressure 0...15 psi 0...30 psi 0...100 psi 0...5 psi Differential pressure 0...15 psi 0...30 psi 0...100 psi SenSym and Sensortechnics reserve the right to make changes to any products herein. SenSym and Sensortechnics do not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. July 2005 / 040 5/5 www.sensortechnics.com
SCC05D
### 物料型号 - SCC系列压力传感器提供了多种型号,包括绝对压力、表压和差压传感器。具体型号如下: - 绝对压力:SCC15A、SCC30A、SCC100A - 表压:SCC15GD2、SCC30GD2、SCC100GD2 - 差压:SCC05D、SCC15D、SCC30D、SCC100D

### 器件简介 - SCC系列提供极低成本的传感器元件,当使用恒定电流源驱动时,具有温度稳定的输出。这些集成电路传感器设计用于成本敏感的应用,不需要在宽温度范围内精确的准确性。该系列适用于与非腐蚀性、非离子工作流体(如空气和干燥气体)一起使用。

### 引脚分配 - Button Sensor或"N"封装: - 1号引脚:输出+ - 2号引脚:输出- - 3号引脚:Vs(电源) - 4号引脚:GND(地) - DIP封装提供5引脚的开路桥配置。

### 参数特性 - 最大额定值: - 供电电流:1.5 mA - 湿度:0至100%RH - 引脚温度(焊接4秒):250°C - 性能特性: - 零压力偏移:-30.0至20.0 mV - 综合线性度、滞后和重复性:0.25%至0.50%FSO - 温度对量程的影响:0.25%至1.50%FSO - 温度对偏移的影响:0.50%至2.00%FSO - 长期稳定性:0.10 mV - 响应时间(10至90%):0.10 ms

### 功能详解 - SCC系列传感器可以测量绝对压力、表压和差压。绝对设备具有内部真空参考和与应用压力成比例的输出电压。差压设备允许在膜片的任一侧施加压力,因此可用于测量差压和/或表压。

### 应用信息 - SCC系列传感器适用于气动控制、汽车诊断、医疗设备、牙科设备和环境控制等应用。

### 封装信息 - SCC系列传感器提供多种封装选项,包括SenSym的标准低成本芯片载体“按钮”封装、塑料端口“N”封装或双列直插式封装(DIP)。所有封装都设计为将感测元件集成到OEM设备中。
SCC05D 价格&库存

很抱歉,暂时无法提供与“SCC05D”相匹配的价格&库存,您可以联系我们找货

免费人工找货