LS013B7DH01

LS013B7DH01

  • 厂商:

    SHARP(夏普)

  • 封装:

    -

  • 描述:

    Graphic LCD Display Module Transflective Black TFT - Monochrome Serial 1.26" (32.00mm) 144 x 168

  • 数据手册
  • 价格&库存
LS013B7DH01 数据手册
No. LCP-2110019B Date 16th Aug 2010 Technical Literature For TFT-LCD Module Model No. LS013B7DH01 Notice The technical Literature is subject to change without any prior notice for the purpose of product improvement. Please contact Sharp or its representative before designing your product based on this literature. Liquid Crystal Display Group SHARP CORPORATION RECORDS OF REVISION REF.PAGE DATE PARAGRAPH DRAWING No. REVISED SUMMARY No. 1st July 2010 First issue P7 P14 Table3-1 Weight was filled in. (Mass: 3.0g) Power consumption Table6-4 16th Aug 2010 and condition2 typ were added. B P19 6-5-5 COM Inversion P23 8-1) Outline dimension of condition1 typ EXTMODE="H" mode of ※1 : The description of LC inversion polarity was corrected. The black mask shape and size was revised. SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 1 NOTICE ○ These specification sheets are the proprietary product of SHARP CORPORATION ("SHARP") and include materials protected under copyright of SHARP. Do not reproduce or cause any third party to reproduce them in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. ○ The application examples in these specification sheets are provided to explain the representative applications of the device and are not intended to guarantee any industrial property right or other rights or license you to use them. SHARP assumes no responsibility for any problems related to any industrial property right of a third party resulting from the use of the device. ○ SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structures and other contents described herein at any time without notice in order to improve design or reliability. Contact SHARP in order to obtain the latest specification sheets before using any SHARP's device. Manufacturing locations are also subject to change without notice. Observe the following points when in using any device in this publication. SHARP takes no responsibility for damage caused by improper use of the devices. The devices in this publication are designed for use in general electronic equipment designs, such as: ・Personal computers ・Office automation ・Telecommunication equipment ・Test and measurement equipment ・Industrial control ・Audio visual and multimedia equipment ・Consumer electronics The appropriate design measures should be taken to ensure reliability and safety when SHARP's devices are used for equipment such as: ・Transportation control and safety equipment(i.e.,aircraft,trains,automobiles,etc.) ・Traffic signals ・Alarm equipment ・Gas leakage sensor breakers ・Various safety devices etc. ○ SHARP's devices shall not be used for equipment that requires extremely high level of reliability, such as: ・Military and space applications ・Nuclear power control equipment ・Medical equipment for life support ○ SHARP assumes no responsibility for any damage resulting from the use of the device which does not comply with the instructions and the precautions specified in these specification sheets. ○ Contact and consult with a SHARP sales representative for any questions about this device. SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 2 [For handling and system design] (1) Handle with care as glass is used in this LCD panel. Dropping or contact against hard object may cause cracks or chips. (2) Be careful to handle this LCD panel in order to avoid injury yourself by panel`s edge as this panel is made of glass and might be a sharp edge. (3) Do not scratch the surface of the polarizer as it is easily damaged. (4) Water droplets on the polarizer must be wiped off immediately as they may cause color changes, or other defects if remained for a long time. (5)Do not leave the LCD panel in direct sun or under ultraviolet ray. (6) To clean LCD panel surface, wipe clean with absorbent cotton or soft cloth. If further cleaning is needed, use IPA (isopropyl alcohol) and wipe clean lightly on surface only. Do not use organic solvents as it may damage the LCD panel terminal area which uses organic material. Also, do not directly touch with finger. When the terminals cleaning are needed, those should be wiped by a soft cloth or a cotton swab without directly touching by hand. (7) Do not expose gate driver, etc. on the panel (circuit area outside panel display area) to light as it may not operate properly. Design that shields gate driver, etc. from light is required when mounting the LCD module. (8) To avoid circuit failure, do not touch panel terminal area. (9) Support for the LCD panel should be carefully designed to avoid stress that exceeds specification on glass surface. (10) When handling LCD module and assembling them into cabinets, be noted that storage in the environment of oxidization or deoxidization gas and the use of such materials as reagent, solvent, adhesive, resin, and etc. which generate these gasses, may cause corrosion and discoloration of LCD modules. (11)To avoid picture uniformity failure, do not put a seal or an adhesive material on the panel surface. (12) Do not use chloroprene rubber as it generates chlorine gas and affects reliability in LCD panel connective area. (13) Protective film is attached to the surface of polarizer on LCD panel to prevent scratches or other damages. Remove this protective film before use. In addition, do not attach the protective film which is removed from LCD module again. When the LCD panel which has the reattached protective film is needed to storage for a long time, the polarizer might have a damage with picture quality failure. (14) Panel is susceptible to mechanical stress and such stress may affect the display. Place the panel on flat surface to avoid stress caused by twist, bend, etc. (15) When transporting LCD panels, secure them in LCD panel tray to avoid mechanical stress. The tray should be conductive to protect LCD panels from static charge. Material used in set or epoxy resin (amine type hardening agent) from packaging, and silicon adhesive (dealcoholized or oxime) all release gas which may affect quality of polarizer. Do confirm compatibility with user materials. (16) As this LCD module is composed electronic circuits, it is sensitive to electrostatic discharge of 200V or more. Handle with care using cautions for the followings: z Operators Operators must wear anti-static wears to prevent electrostatic charge up to and discharge from human body. SPEC No. LCP-2110019B z MODEL No. PAGE LS013B7DH01 3 Equipment and containers Process equipment such as conveyer, soldering iron, working bench and containers may possibly generate electrostatic charge up and discharge. Equipment must be grounded through 100Mohms resistance. Use ion blower. z Floor Floor plays an important role in leaking static electricity generated in human body or equipment. If the floor is made of insulated material (such as polymer or rubber material), such static electricity may charge. Proper measure should be taken to avoid static electricity charge (electrostatic earth: 100Mohms).There is a possibility that the static electricity is charged to them without leakage in case of insulating floor, so the electrostatic earth:1×108Ω should be made. z Humidity Humidity in work area relates to surface resistance of the persons or objects that generate electrostatics, and it can be manipulated to prevent electrostatic charge. Humidity of 40% or lower increases electrostatic earth resistance and promotes electrostatic charging. Therefore, the humidity in the work area should be kept above 40%. Specifically for film peeling process or processes that require human hands, humidity should be kept above 50% and use electricity removal blower. z Transportation/Storage Containers and styroform used in transporation and storage may charge electrostatic (from friction and peeling) or electrostatic charge from human body, etc. may cause containers and styroform to have induced charge. Proper electrostatic measure should be taken for containers and storage material. SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 4 [For operating LCD module] (1) Do not operate the LCD panel under outside of electrical specification. Otherwise LCD panel may be damaged. (2) Do not use the LCD panel under outside of specified driving timing chart. Otherwise LCD panel may not have proper picture quality. (3) A still image should be displayed less than two hours, if it is necessary to display still image longer than two hour, display image data must be refreshed in order to avoid sticking image on LCD panel. (4) If LCD module takes a static electricity, as the display image which is written into pixel memory might not be displayed, Data update should be executed frequently. (5) It is neither a breakdown nor a defective indication though very slight change in black level might be periodically seen in a black part on the black display image according to the source of light (angle of the luminance and the source of light). [Precautions for Storage] (1) After opening the package, do not leave the LCD panel in direct sun or under strong ultraviolet ray. Store in dark place. (2) In temperature lower than specified rating, liquid crystal material will coagulate. In temperature higher than specified rating, it isotropically liquifies. In either condition, the liquid crystal may not recover its original condition. Store the LCD panel in at or around room temperature as much as possible. Also, storing the LCD panel in high humidity will damage the polarizer. Store in normal room temperature as much as possible. (3) Keeping Method a. Don't keeping under the direct sunlight. b. Keeping in the tray under the dark place. SPEC No. LCP-2110019B MODEL No. PAGE LS013B7DH01 5 [Other Notice] (1) Operation outside specified environmental conditions cannot be guaranteed. (2) As power supply (VDD-GND、VDDA-GND) impedance is lowered during use, bus controller should be inserted near LCD module as much as possible. (3) Polarizer is applied over LCD panel surface. Liquid crystal inside LCD panel deteriorates with ultraviolet ray. The panel should not be left in direct sun or under strong ultraviolet ray for prolonged period of time even with the polarizer. (4) Disassembling the LCD module will cause permanent damage to the module. Do not disassemble the module. (5) If LCD panel is broken, do not ingest the liquid crystal from the broken panel. If hand, leg, or clothes come in contact with liquid crystal, wash off immediately with soap. (6) ODS (specific chlorofuorocarbon, specific halon, 1-1-1 trichloroethane, carbon tetrachloride) are not used or contained in material or all production processes of this product. (7) Observe all other precautionary requirements in handling general electronic components. Discarding liquid crystal modules LCD Panel : Dispose of as glass waste. This LCD module contains no harmful substances. The liquid crystal panel contains no dangerous or harmful substances. This liquid crystal panel contains only an extremely small amount of liquid crystal (approximately 100mg) and therefore it will not leak even if the panel should break. Its median lethal dose (LD50) is greater than 2,000 mg/kg and a mutagenetic (Aims test: negative) material is used. SPEC No. LCP-2110019B MODEL No. LS013B7DH01 PAGE 6 Contents 1. Outline ...............................................................................................................................................7 2. Characteristics..................................................................................................................................7 3. Mechanical Specification.................................................................................................................7 4. Input terminal names and functions...............................................................................................8 5. Absolute Maximum Rating ..............................................................................................................9 6. Electrical characteristics ...............................................................................................................10 7. Optical characteristics...................................................................................................................21 8. Module outline ................................................................................................................................23 9. External capacitors ........................................................................................................................24 10. External Power Supply Circuit ....................................................................................................25 11. Zebra connector ...........................................................................................................................26 12. Packaging......................................................................................................................................27 13. Reliability Test Conditions ..........................................................................................................29 SPEC No. MODEL LCP-2110019B No. PAGE 7 LS013B7DH01 1. Outline This TFT-LCD module is a reflective active-matrix with slightly transmissive memory liquid crystal display module with CG silicone thin film transistor. Module outline is indicated in fig 8-1. 2. Characteristics ・ Transflective panel of white and black ・ 1.26” screen has 144x 168 resolusion. (24192 pixels stripe array) ・ Display control by serial data signal communication. ・ Arbitrary line data renewable. ・ 1bit internal memory for data storage within the panel. ・ Thin, light-weight and compact module with monolithic technology. ・ Super low power consumption TFT panel. ・ Zebra connecter 3. Mechanical Specification Table 3-1 Item Specification unit Screen size 3.2 (1.26”) cm Viewing Area 20.88 (H) × 24.36 (V) mm Dot configuration 144 (H) × 168 (V) Dot Dot pitch 0.145 (H) × 0.145 (V) mm Pixel Array Stripe Array - 24.88 (W) × 33.00 (H) × 1.64 (D) mm Mass 3.0 g Surface Hardness 3H Pencil hardness Outline Dimension (Note) Detail dimension and tolerance are shown in fig. 8-1 SPEC No. MODEL LCP-2110019B 4. Input terminal names and functions Table4-1 Terminal symbol I/O No. PAGE 8 LS013B7DH01 Function Remark 1 TEST1 - Test terminal 【Remark4-1】 2 TEST2 - Test terminal 【Remark4-1】 3 SCLK INPUT Serial clock signal 4 SI INPUT Serial data input signal 5 SCS INPUT Chip select signal 6 EXTCOMIN INPUT External COM inversion signal input (H: enable) 7 DISP INPUT Display ON/OFF signal 8 VDDA POWER Power supply (Analog) 9 VDD POWER Power supply (Digital) 10 EXTMODE INPUT COM inversion select terminal 11 VSS GND GND(Digital) 12 VSSA GND GND(Analog) 13 TEST3 - Test terminal 【Remark4-3】 【Remark4-2】 【Remark4-1】 【Remark4-1】 14 TEST4 Test terminal 【Remark4-1】Test terminal should be OPEN. 【Remark4-2】When EXTMODE is ”H”, EXTCOMIN signal is enable. When EXTMODE is ”L” ,sirial input flag is enable. “H”mode; connect the EXTMODE toVDD, ”L” mode; connect the EXTMODE to VSS. 【Remark4-3】The display ON/OFF signal is only for display. Data in the memory will be saved at the time of ON/OFF. When it’s ”H”, data in the memory will display, when it’s ”L”, white color will diaplay and data in the memory will be saved. 4-2)Recommended Circuit COM signal serial input EXTMODE=”L” External COM signal input EXTMODE=”H” SPEC No. MODEL LCP-2110019B No. PAGE 9 LS013B7DH01 5. Absolute Maximum Rating Table5-1 ( GND=0V ) Power supply voltage Item Symbol MIN. MAX. Unit Analog VDDA -0.3 +5.8 V VDD -0.3 +5.8 V [Remark5-1] VDD V [Remark5-2] Logic Input signal voltage(high) Input signal voltage(low) Strage Temperature Operation Temperature (at panel surface) -0.3 Remark V Tstg -30 +80 ℃ [Remark5-3,4] Topr1 -20 +70 ℃ [Remark5-5] [Remark5-1] Applies to EXTMODE. [Remark5-2] Applies to SCLK, SI, SCS, DISP, EXTCOMIN. [Remark5-3] Do not exceed this temperature in any parts of module. [Remark5-4] Maximum wet bulb temperature is 57℃ or lower. No condensation is allowed. Cndensation will cause electeical leak and may cause the module to not meet this specification. [Remark5-5] Operating temperature is the temperature that guarantees only for the operation. For contrast, response time, and other display quality determination, use Ta=+25℃. SPEC No. MODEL LCP-2110019B No. PAGE 10 LS013B7DH01 6. Electrical characteristics 6-1) TFT LCD panel drive Table6-1 Recommended operating Condition Item Power supply symbol Analog VSS(GND)=0V、Ta=+25℃ MIN. TYP. MAX. Unit Remark VDDA +4.8 +5.0 +5.5 V VDD +4.8 +5.0 V [Remark6-1] Input signal voltage Hi VIH +2.70 +3.00 +5.5 *VDD V [Remark6-2] Lo VIL VSS VSS VSS+0.15 V Logic *It can be operated below VDD voltage, however, operation around 3V is recommended. [Remark6-1] Applies to EXTMODE=”H” [Remark6-2] Applies to SCLK, SI, SCS, DISP, EXTCOMIN. SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 11 6-2) Power supply sequence On Sequence ① ② T1 T2 Normal operation Off sequence ③※1 ④※1 T3 T4 ⑤ ⑥ ⑦ T5 T6 T7 VDD/VDDA(5V) GND GND DISP GND GND EXTCOMIN GND SCS GND ※2 Normal operation ※2 GND Others GND ※2 Normal operation ※2 GND Normal operation GND ※Refer to timing chart and AC timing characteristics for detail ※1 ③ and ④ may be opposite (however, TCOM polarity inversion will not occur even with EXTCOMIN between DISP=”L”. Also, when DISP and EXTCOMIN are simultaneously started up, allow 30us or more before SCS starts up (It may be less than 60us). ※2 Setting value for pixel memory initialization SCS=Driving accordingly to clear pixel internal memory method (use all clear flag or write all screen white) S1=M2 (all clear flag) = “H” or write white SCLK: Normal Driving [ON Sequence] (1) 5V rise time (depends on IC) (2) Pixel memory initialization T2: 1V or more Initialize with M2 (all clear flag) or write all screen white (3) Release time for initialization of TCOM latch T3: 30us or more Time required to release COM related latch circuit initialization which is initializing using DISP signals (4) TCOM polarity initialization time T4: 30us or more Time required initializing TCOM polarity accordingly to EXTCOMIN input [Normal Operation] Duration of normal driving [Off Sequence] (5) Pixel memory initialization time T5: 1V or more (6) VA, VB, VCOM initialization time T6: 1V or more (7) 5V falling time (Depends on IC) [Remark] Precaustions at ehte time of power on and power off. Remark 1)When power on , VDDand VDDA are same timem or VDD should be faster than the VDDA. Remark 2) When power off, VDD and VDDA are same time or VDDA shoud be faster than the VDD. SPEC No. MODEL LCP-2110019B 6-3) Input signal characteristics Table6-3-1 No. PAGE VDDA=+5.0V、VDD=+5.0V、GND=0V、Ta=25℃ Item Symbol MIN TYP MAX Unit Frame frequency fSCS 1 - 60 Hz Clock frequency fSCLK 1 2 MHz Vertical Interval tV 16.66 - 1000 ms COM Frequency fCOM 0.5 - 30 Hz Table 6-3-2 12 LS013B7DH01 Remark VDDA=+5.0V、VDD=+5.0V、GND=0V、Ta=25 Item Symbol MIN TYP MAX Unit SCS Rising time trSCS - - 50 ns SCS Falling Time tfSCS - - 50 ns SCS High duration twSCSH 92 - - us 12 - - us twSCSL 1 - - us SCS set up time tsSCS 3 - - us SCS hold time thSCS 1 - - us SI frequency fSI - 0.5 1 MHz SI Rising time trSI - - 50 ns SI Folling time tfSI - - 50 ns SI set up time tsSI (120) - - ns SI hold time thSI (125) - - ns SCLK Rising time trSCLK - - 50 ns SCLK Folling time tfSCLK - - 50 ns SCLK High duration twSCLKH 200 450 - ns SCLK Low duration twSCLKL 200 450 - ns EXTCOMIN signal freequency fEXTCOMIN 1 60 Hz EXTCOMIN signal rising time trEXTCOMIN - - 50 ns EXTCOMIN signal folling time twEXTCOMIN - - 50 ns EXTCOMIN signalHigh duration thlEXTCOMIN 1 DISP Rising time trDISP - - 50 ns DISP Folling time tfDISP - - 50 ns SCS Low duration us 【Remark 6-3】 EXTCOMIN frequency should be made lower than frame frequency. Remark [Remark6-3] SPEC No. MODEL LCP-2110019B No. PAGE 13 LS013B7DH01 SCS, SI, SCLK signal twSCSH 50% SCS twSCSL 90% 90% 50% 10% 10% trSCS tsSCS SI 10% thSCS 90% 90% 10% 10% 10% trSI tfSI tsSI thSI twSCLKH 90% SCLK 90% 10% 50% twSCLKL 50% 50% 50% 10% trSCLK tfSCLK EXTCOMIN signal fEXTCOMIN EXTCOMIN 90% 90% 50% 50% 10% 10% trEXTCOMIN tfEXTCOMIN twEXTCOMINH DISP signal 90% DISP 90% 10% 10% trDISP tfDISP ※SCS,SI,SCLK、DISP、EXTCOMIN: 3V input voltage 50% tfSCS 50% SPEC No. MODEL LCP-2110019B 6-4) Power consumption (Average) Table6-4 No. PAGE LS013B7DH01 14 Ta=25℃ Item MIN TYP MAX unit Remark Condition1 - 15 - uW [Remark6-4] Condition2 - 50 - uW [Remark6-4] * Measurement Condition 1 Display mode (no display data update), Display pattern: Vertical stripe display * Measurement Condition 2 Data update mode (with display data update: 1Hz) Common inversion with VDD=5V、VDDA=5V、fSCLK=1MHz、fSCS=1Hz, Display pattern: Vertical stripe display 【Remark 6-4】 This is value in steady condition, not the falue of peak power at the time of COM operation. Some marging for power supply is recommended. We recommend capacitor for VDD and VDDA. (If VDD and VDDA are on separate systems, we recommend capacitor for each.) SPEC No. MODEL LCP-2110019B No. PAGE 15 LS013B7DH01 6-5) Input Signal Timing Chart 6-5-1 Data update mode (1 line) Updates data of only one specified line. (M0=”H”、M2=”L”) twSCSH SCS twSCSL thSCS tsSCS M0 SI tsSI M1 thSI M2 DMY DMY DMY DMY DMY AG0 AG1 AG2 AG3 AG4 AG5 AG6 AG7 twSCLKL D1 D2 D3 D4 D141 D142 D143 D144 DUMMY DATA(don't care) twSCLKH SCLK Mode selection period (3ck+5ckDMY) Gate line address period (8ck) Data writing period (144ck) Data transfer period (16ck) M0: Mode flag. Set for “H”. Data update mode (Memory internal data update) When “L”, display mode (maintain memory internal data). M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Refer to 6-5-4) All Clear Mode to execute clear. DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※ Data write period Data is being stored in 1st latch block of binary driver on panel. ※ Data transfer period Data written in 1st latch is being transferred (written) to pixel internal memory circuit. ※For gate line address setting, refer to 6-6) Input Signal and Display. ※M1: Frame inversion flag is enaled when EXTMODE=”L”. ※When SCS becomes “L”, M0 and M2 are cleared. SPEC No. MODEL LCP-2110019B No. PAGE 16 LS013B7DH01 6-5-2 Data Update Mode (Multiple Lines) Updates arbitrary multiple lines data. (M0=”H”、M2=”L”) twSCSH SCS tsSCS SI M0 tsSI M1 M2 DMY thSI DMY DMY twSCLKL DMY DMY AG0 AG1 AG2 AG3 AG4 AG5 AG6 AG7 D1 D2 D3 D4 D141 D142 D143 D144 DUMMY DATA(don't care) AG0 AG1 AG6 AG7 D1 D2 twSCLKH SCLK Gate line address period (8ck) Mode selection period (3ck+5ckDMY) Data writing period (144ck) GL1st line Data writing period (144ck) Data transfer period (8ck(Dummy)+8ck(Address)=16ck) GL2nd line twSCSH twSCSL thSCS D143 D144 GL(n-1)th line DUMMY DATA(don't care) AG0 AG1 AG2 AG5 AG6 Data transfer period (8ck(Dummy)+8ck(Address)=16ck) GL(n)th line AG7 D1 D2 D143 D144 Data writing period (144ck) DUMMY DATA(don't care) Data transfer period (16ck) M0: Mode flag. Set for “H”. Data update mode (Memory internal data update) When “L”, display mode (maintain memory internal data). M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Refer to 6-5-4) All Clear Mode to execute clear. DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※ Data write period Data is being stored in 1st latch block of binary driver on panel. ※ Data transfer period For example, during GL2nd line data transfer period, GL 2nd line address is latched and GL1st line data is transferred from 1st latch to pixel internal memory circuit at the same time. ※ For gate line address setting, refer to 6-6) Input Signal and Display. ※ Input data continuously. ※ M1: Frame inversion flag is enabled when EXTMODE=”L”. ※ When SCS becomes “L”, M0 and M2 are cleared. SPEC No. MODEL LCP-2110019B No. PAGE 17 LS013B7DH01 6-5-3 Display Mode Maintains memory internal data (maintains current display). (M0=”L”、M2=”L”) tV twSCSH twSCSL SCS tsSCS SI thSCS M0 tsSI M1 M2 DUMMY DATA(don't care) thSI SCLK Mode selection period (3ck) Data transfer period (More than 13ck) M0: Mode flag. Set for “H”. Data update mode (Memory internal data update) When “L”, display mode (maintain memory internal data). M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Refer to 6-5-4) All Clear Mode to execute clear. DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※ M1: Frame inversion flag is enabled when EXTMODE=”L” ※ When SCS becomes “L”, M0 and M2 are cleared. M0 M1 M2 DUMMY DATA(don't care) SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 6-5-4 All Clear Mode Clears memory internal data and writes white. (M0=”L”、M2=”H”) tV twSCSH twSCSL SCS thSCS tsSCS SI M0 tsSI M1 M2 DUMMY DATA(don't care) M0 M1 thSI SCLK Mode selection period (3ck) Data transfer period (More than 13ck) M0: Mode flag. Set it “L”. M1: Frame inversion flag. When “H”, outputs VCOM=”H”, and when “L”, outputs VCOM=”L”. When EXTMODE=”H”, it can be “H” or “L”. M2: All clear flag. Set it “H” DUMMY DATA: Dummy data. It can be “H” or “L” (“L” is recommended.) ※ M1: Frame inversion flag is enabled when EXTMODE=”L”. ※ When SCS becomes “L”, M0 and M2 are cleared. M2 DUMMY DATA(don't care) 18 SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 19 6-5-5 COM Inversion There are two types of inputs, COM signal serial input (EXTMODE=”L”) and external COM signal input (EXTMODE=”H”). EXTMODE=“L” SCS SI M0 M1 M2 ※1 M0 M1 M2 ※1 M0 M1 M2 ※1 COM fCOM ※2 ※2 M1:LC polarity inversion flag: If M1 is "H" then VCOM="H" is output. If M1 is "L" then VCOM="L" is output. ※1:LC inversion has been changed by M1 flag statement. ※2:The periods of plus polarity and minus polarity should be same length as much as possible. EXTMODE="H" (COM inversion timing has two conditions ) ①: the EXTCOMIN input during high period of the SCS signal . SCS twEXTCOMINH fEXTCOMIN EXTCOMIN ※1 ※1 COM fCOM ※2 ※2 ※1:LC inversion polarity has been set by the falling edge of SCS signal. ※2:The period of EXTCOMIN should be constant. ②: the EXTCOMIN input during low period of the SCS signal . SCS EXTCOMIN fEXTCOMIN ※3 twEXTCOMINH ※3 COM fCOM ※4 ※3:LC inversion polarity has been set by the rising edge of EXTCOMIN. ※4:The period of EXTCOMIN should be constant. ※4 SPEC No. LCP-2110019B 6-6) Input Signal and Display, Gate address(Line) Setting Data position in display〔H,V〕 UP P1,L1 P2,L1 P1,L2 P2,L2 P3,L1 P144,L1 P1,L3 Display side up P1,L168 P144,L168 Gate line address setting GL 1 2 3 4 5 6 7 8 : 161 162 163 164 165 166 167 168 AG0 AG1 AG2 AG3 AG4 AG5 AG6 AG7 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 0 1 0 0 0 0 0 0 1 1 0 0 0 0 0 1 1 1 0 0 0 0 0 0 0 0 1 0 0 0 0 : : : : : : : : 1 0 0 0 0 1 0 1 0 1 0 0 0 1 0 1 1 1 0 0 0 1 0 1 0 0 1 0 0 1 0 1 1 0 1 0 0 1 0 1 0 1 1 0 0 1 0 1 1 1 1 0 0 1 0 1 0 0 0 1 0 1 0 1 MODEL No. LS013B7DH01 PAGE 20 SPEC No. MODEL LCP-2110019B No. PAGE 21 LS013B7DH01 7. Optical characteristics Table 7-1 Ta=25 Item Symbol Viewing angle CR≧2 MIN. TYP. MAX. unit H θ21,θ22 (40) (55) °(degree) V θ11 (40) (60) °(degree) θ12 (40) (60) °(degree) Contrast ratio CR. (14) Reflecivity ratio R (17) % Transmissivity ratio T (0.3) % Rise τr 10 ms Fall τd 20 ms White x (0.307) y (0.330) Response time Panel Chromaticity Remark [Remark7-1] [Remark7-2、3] [Remark7-3] [Remark 7-3,4] [Remark7-3] [Remark7-3] Optical characteristics measurement equipment. Figure 7-2 is for contrast ratio, reflectivity ratio, and panel chromaticity measurement, and figure 7-3 is for response time measurement. Both are to be conducted in a dark or room equipment to a dark room Measurement equipment Measurement equipment (CM-2002) (LCD-5200) Normal line Light receiver Normal line Light source Light source Light receiver -30° Integrating sphere LCD panel LCD panel Display center Fig7-2 Contrast ratio, Reflection ratio, Panel chromaticity of white Display center Fig7-3 response time SPEC No. MODEL LCP-2110019B [Remark7-1] Defintion of Viewing Angle No. PAGE LS013B7DH01 Normal Line Δθ22 Δθ11 Δθ12 Δθ21 6 o’clock direction [Remark7-2] Defintion of Contrast Retio Contrast ratio(CR) = Reflection intensity in white display Reflection intensity in black display [Remark7-4] Respons time (Change in reflection ratio) It’s difined by the time change of optical receiver output when signal is input to display white or black White Black Optical receiver output (Incremental) Time White 22 SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 8. Module outline 8-1) Outline dimension of the 1.26” (144 x 168) panel fig.8-1 fig. 8-2 fig. 8-3 23 SPEC No. LCP-2110019B MODEL No. LS013B7DH01 9. External capacitors Fig. 9-1 External capacitor recommendation capacity value <Recommended capacity value> C1:DISP- VSS: rank B 0.1uF Ceramic capacitor C2:VDDA- VSS: rank B 1uF Ceramic capacitor C3:VDD- VSS: rank B 1uF Ceramic capacitor ※Above circuit and parts are only recommendation. For actual use, please evaluate their conformity with your system and design. (Capacitor pressure resistance can be larger than resistance indicated above.) PAGE 24 SPEC No. MODEL LCP-2110019B No. PAGE 25 LS013B7DH01 10. External Power Supply Circuit An external power supply circuit is necessary to drive the Pixel Memory LCD with the 3V battery. Table 1-1 shows power supply IC of the recommendation. Table 1-1 Maker Model Number Note SII S-8821 Charge pump type National Semiconductor LM2750 Charge pump type Refer to specifications of each power supply IC for a detailed specification. Set the constant value after it evaluating it sufficiently by an actual application when you use it. Electrical specification Table 2-1 Vin [V] Vout min max min typ max Iout [A] S-8821 2.8 5.0 4.9 5.0 5.1 0.04 LM2750 2.7 5.6 4.8 5.0 5.2 0.04 Model Number Refer to specifications of each power supply IC for a detailed specification. Set the constant value after it evaluating it sufficiently by an actual application when you use it. Reference circuit The reference circuit is shown below. S-8821 LM2750 SPEC No. LCP-2110019B MODEL No. LS013B7DH01 11. Zebra connector Contact Resistance :lower than 100Ω 【Recommended zebra connector】 Shin-Etsu Polymer: SX type Recommended size L:27.7±0.2mm W:1.5±0.1mm H:2.0±0.1mm P:0.03mm Recommended compression ratio:15±8% The zebra connector placement position 1.SX Specifications(A figure of reference) Fig 11-1 PAGE 26 SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 27 12. Packaging 12-1) Serial number (Ink-jet print) Will be indicated on serial number label as indicated in Figure 12-1 outline dimension figure. Model number Print location is TBD Print structure ABC D Serial number specifications A:a single figure of the year B:month(1,2....9,X,Y,Z) C:day D:serial number Fig. 12-1 Serial number print position 12-2) Forwarding form 1) Piling number of cartons : TBD Package quality in a carton : TBDpcs 2) Storage condition Temperature: 0~40° Humidity: 60%RH or lower (at 40°) There should be no condensation at low temperature and high humidity. Atmosphere: No harmful gas, such as acid or alkali, which causes severe corrosion on electronic parts and wiring, are to be detected. Period: About 3 months Opening the package: In order to prevent electrostatic damage to TFT modules, room humidity should be made over 50%RH and take effective measure such as use of earth when opening the package. SPEC No. MODEL LCP-2110019B No. PAGE LS013B7DH01 12-3) Packaging Packageing size :578mmx382mmx153mm Fig. 12-2 Packaging Form 28 SPEC No. MODEL LCP-2110019B No. PAGE 29 LS013B7DH01 13. Reliability Test Conditions 13-1) Reliability test items Table13-1 Test Item 1 2 3 Test condition Remark High temperature storage test Ta=80degrees Celsius 240h Low temperature storage test Ta=-30degrees Celsius 240h High temperature and high humidity Tp=40degrees Celsius/95%RH 240h operating test 4 High temperature operating test Tp=70degrees Celsius 240h 5 Low temperature operating test Tp=-20degrees Celsius 240h Shock test Ta=-30degrees Celsius (1h)~+80 degrees (Non operating test) Celsius (1h) / 5 cycle Electro static discharge test ±200V、200pF(0Ω) each terminai: 1 time 6 7 [Remark] Ta = Ambient temperature, Tp = Panel temperature (Evaluation method) In the standard condition, there shall be no practical problems that may affect the display function. 13-2) Panel surface stress spesification Panel surface stress spesification has been defined as a parameter “Force of stress [N]” without no picture failer. Load testing: Minimum 120[N] Test condition ) Test stracture Press point Press Jig Press speed Support Press time :LCD panel with polarizer :Center of LCD panel :φ10mm column :1mm/minute :fixed on stage :5 seconds after achivement of the press strength,then reless it. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Sharp Microelectronics: LS013B7DH01
LS013B7DH01 价格&库存

很抱歉,暂时无法提供与“LS013B7DH01”相匹配的价格&库存,您可以联系我们找货

免费人工找货