0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MR-QK97-04GB5

MR-QK97-04GB5

  • 厂商:

    SHIELD

  • 封装:

  • 描述:

    MR-QK97-04GB5 - Rubber, rubber insulation, RN-F series, HAR approved - SHIELD s.r.l.

  • 详情介绍
  • 数据手册
  • 价格&库存
MR-QK97-04GB5 数据手册
CABLES - CAVI MR-PK MR-QK Rubber, rubber insulation, RN-F series, HAR approved Description. Conductor insulation: EI4 rubber. Outer sheath: EM2 rubber. Application. Suitable for wet and dry environments, permanent outdoor and indoor use. Approved with HAR mark (European Harmonization) up to 5 wires. Flame resistance degree: IEC 60332-1. Good resistance to oils, water and weather. Good resistance to abrasion. Max working voltage: 300/500 V up to 1,00 mm2 and 450/750 V over. Test voltage: 2000 V up to 1,00 mm2 and 2500 V over, according to norms. Note to table: (a) example: 3 = three wires; 2+1 = two wires + yellow/green earth. (b) colours: A = brown, blue, black, white, grey; yellow/green earth if present. B = brown, grey, black, blue; green/yellow earth if present. (c) HAR cable construction classification. Gomma, isolante gomma, serie RN-F, omologato HAR Descrizione. Isolante conduttori: gomma EI4. Guaina esterna: gomma EM2. Impiego. Adatto per ambienti secchi e umidi, uso permanente in ambienti interni ed esterni. Omologato con marchio HAR (Armonizzazione Europea) fino a 5 conduttori. Resistenza alla fiamma: IEC 60332-1. Buona resistenza a oli, acqua e intemperie. Buona resistenza all’abrasione. Tensione massima di lavoro: 300/500 V fino a 1,00 mm2 e 450/750 V oltre. Tensione di prova: 2000 V fino a 1,00 mm2 e 2500 V oltre, secondo norme. Note alla tabella: (a) esempio: 3 = tre conduttori; 2+1 = due conduttori + terra giallo/verde. (b) colori: A = marrone, blu, nero, bianco; giallo/verde terra se presente. B = marrone, grigio, nero, blu; giallo/verde terra se presente. (c) classificazione HAR della costruzione del cavo. Formation Formazione Descriptive code Codice descrittivo Short code Codice breve Refer. or style Rifer. o style Sheath colour Colore guaina Wires colour Colore cond. (b) Copper class Classe rame IEC 60228 Static application Applicazione statica °C Dynamic application Applicazione dinamica °C Note Nota n x mm2 (a) (c) RAL 2x0,75 (2+1)x0,75 3x0,75 (3+1)x0,75 2x1,00 (2+1)x1,00 3x1,00 (3+1)x1,00 2x1,50 (2+1)x1,50 3x1,50 (3+1)x1,50 (4+1)x1,50 (6+1)x1,50 (9+1)x1,50 (11+1)x1,50 (18+1)x1,50 MR-PK9 MR-PK95-02XA5 MR-PK95-03GA5 MR-PK95-03XB5 MR-PK95-04GB5 MR-PK96-02XA5 MR-PK96-03GA5 MR-PK96-03XB5 MR-PK96-04GB5 MR-PK97-02XA5 MR-PK97-03GA5 MR-PK97-03XB5 MR-PK97-04GB5 MR-PK97-05GB5 MR-PK97-07GN5 MR-PK97-10GN5 MR-PK97-12GN5 MR-PK97-19GN5 0,75 536 5R2 6R1 6R2 7R1 7R2 7R5 7R6 769 RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F HAR RN-F RN-F RN-F RN-F bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 A A B B A A B B A A B B B N N N N 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 -30...+ 60 PUR, rubber insulation, BQ-F series, HAR approved, cold resistant (- 40°C) Description. Conductor insulation: EI6 rubber. Sheath of matt halogen free polyether polyurethane (PUR). Application. Suitable for wet and dry environments, permanent indoor and outdoor use even at very low temperature. Approved with HAR mark (European Harmonization). Good resistance to oils, water and weather. Good resistance to abrasion, tearing and cutting. Good flexibility at low temperature down to -40°C. Max working voltage: 300/500 V up to 1,00 mm2 and 450/750 V. Test voltage: 2000 V up to 1,00 mm2 and 2500 V over, according to norms. Note to table: (a) example: 3 = three wires; 2+1 = two wires + yellow/green earth. (b) colours: A = brown, blue, black, white, grey; yellow/green earth if present. B = brown, grey, black, blue; green/yellow earth if present. (c) HAR cable construction classification. 1,50 1,00 PUR, isolante gomma, serie BQ-F, omologato HAR, resistente al freddo (- 40°C) Descrizione. Isolante conduttori: gomma EI6. Guaina in poliuretano (PUR) polietere opaco senza alogeni. Impiego. Adatto per ambienti secchi e umidi, uso permanente in ambienti interni ed esterni anche a tempertature molto basse. Omologato con marchio HAR (Armonizzazione Europea). Buona resistenza a oli, acqua e intemperie. Buona resistenza a abrasione, taglio e lacerazione. Buona flessibilità a basse temperature fino a -40°C. Tensione massima di lavoro: 300/500 V fino a 1,00 mm2 e 450/750 V oltre. Tensione di prova: 2000 V fino a 1,00 mm2 e 2500 V oltre, secondo norme. Note alla tabella: (a) esempio: 3 = tre conduttori; 2+1 = due conduttori + terra giallo/verde. (b) colori: A = marrone, blu, nero, bianco; giallo/verde terra se presente. B = marrone, grigio, nero, blu; giallo/verde terra se presente. (c) classificazione HAR della costruzione del cavo. Formation Formazione Descriptive code Codice descrittivo Short code Codice breve Refer. or style Rifer. o style Sheath colour Colore guaina Wires colour Colore cond. (b) Copper class Classe rame IEC 60228 Static application Applicazione statica °C Dynamic application Applicazione dinamica °C Note Nota n x mm2 (a) (c) RAL 2x0,75 (2+1)x0,75 3x0,75 (3+1)x0,75 2x1,00 (2+1)x1,00 3x1,00 (3+1)x1,00 2x1,50 (2+1)x1,50 3x1,50 (3+1)x1,50 MR-QK9 MR-QK95-02XA5 MR-QK95-03GA5 MR-QK95-03XB5 MR-QK95-04GB5 MR-QK96-02XA5 MR-QK96-03GA5 MR-QK96-03XB5 MR-QK96-04GB5 MR-QK97-02XA5 MR-QK97-03GA5 MR-QK97-03XB5 MR-QK97-04GB5 0,75 5R3 5R4 6R3 6R4 7R3 7R4 BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR BQ-F HAR bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 bk 9005 A A B B A A B B A A B B 5 5 5 5 5 5 5 5 5 5 5 5 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 -40...+ 80 33 MR-P 1,50 1,00 www.shield.net
MR-QK97-04GB5
### 物料型号 - MR-PK9系列:包括MR-PK95-02XA5、MR-PK95-03GA5、MR-PK95-03XB5、MR-PK95-04GB5等型号,这些型号的电缆适用于不同的应用场景,如动态和静态应用。 - MR-QK9系列:包括MR-QK95-02XA5、MR-QK95-03GA5、MR-QK95-03XB5、MR-QK95-04GB5等型号,这些型号的电缆同样适用于不同的应用场景。

### 器件简介 - RN-F系列:由EI4橡胶绝缘和EM2橡胶外护套组成,适用于潮湿和干燥环境,室内外长期使用,具有HAR认证,具有良好的耐油、耐水和耐候性,以及良好的耐磨损性。 - BQ-F系列:由EI6橡胶绝缘和无卤素聚醚PUR外护套组成,具有HAR认证,适用于低温环境,具有良好的耐油、耐水和耐候性,以及良好的耐磨损、抗撕裂和抗切割性。

### 引脚分配 - MR-PK9系列:包括2x0.75、(2+1)x0.75、3x0.75、(3+1)x0.75等不同线径和线数的配置。 - MR-QK9系列:包括2x0.75、(2+1)x0.75、3x0.75、(3+1)x0.75等不同线径和线数的配置。

### 参数特性 - 工作电压:300/500V(1.00mm²以下)和450/750V(1.00mm²以上)。 - 测试电压:2000V(1.00mm²以下)和2500V(1.00mm²以上)。 - 温度范围:-30°C至+60°C(RN-F系列)和-40°C至+80°C(BQ-F系列)。

### 功能详解 - RN-F系列:适用于潮湿和干燥环境,室内外长期使用,具有良好的耐油、耐水和耐候性。 - BQ-F系列:适用于低温环境,具有良好的耐油、耐水和耐候性,以及良好的耐磨损、抗撕裂和抗切割性。

### 应用信息 - 这些电缆适用于各种环境,包括潮湿和干燥环境,室内外长期使用,特别是在需要耐低温的应用中。

### 封装信息 - 外护套颜色:黑色(bk)。 - 标准:符合IEC 60228和RAL标准。
MR-QK97-04GB5 价格&库存

很抱歉,暂时无法提供与“MR-QK97-04GB5”相匹配的价格&库存,您可以联系我们找货

免费人工找货