0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
17JUH92BD

17JUH92BD

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    STARTER,COMBO SZ4,50-200AMPS,N1,

  • 数据手册
  • 价格&库存
17JUH92BD 数据手册
Data sheet US2:17JUH92BD Non-reversing motor starter, Size 4, Three phase full voltage, Solid-state overload relay, OLRelay amp range 50-200A, 208VAC 60HZ coil, Combination type, 200A non-fusible disconnect, Enclosure NEMA type 1, Indoor general purpose use, Standard width enclosure product brand name Class 17 & 25 design of the product Full-voltage non-reversing motor starter with non-fusible disconnect special product feature ESP200 overload relay General technical data Height x Width x Depth [in] 36 × 24 × 8 in touch protection against electrical shock (NA for enclosed products) installation altitude [ft] at height above sea level maximum 6560 ft ambient temperature [°F] ● during storage -22 ... +149 °F ● during operation -4 ... +104 °F ambient temperature ● during storage -30 ... +65 °C ● during operation -20 ... +40 °C Horsepower ratings yielded mechanical performance [hp] for 3-phase AC motor ● at 200/208 V rated value 40 hp ● at 220/230 V rated value 50 hp ● at 460/480 V rated value 100 hp ● at 575/600 V rated value 100 hp Contactor size of contactor NEMA controller size 4 number of NO contacts for main contacts 3 operational current at AC at 600 V rated value 135 A mechanical service life (switching cycles) of the main contacts typical 5000000 Auxiliary contact number of NC contacts at contactor for auxiliary contacts 0 number of NO contacts at contactor for auxiliary contacts 1 number of total auxiliary contacts maximum 7 contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600) Coil type of voltage of the control supply voltage AC control supply voltage ● at AC at 60 Hz rated value holding power at AC minimum US2:17JUH92BD Page 1/2 208 V 22 W 1.14.2021 Subject to change without notice © Copyright Siemens apparent pick-up power of magnet coil at AC 510 V·A apparent holding power of magnet coil at AC 51 V·A operating range factor control supply voltage rated value of magnet coil 0.85 ... 1.1 percental drop-out voltage of magnet coil related to the input voltage 50 % switch ON delay time 18 ... 34 ms OFF delay time 10 ... 12 ms Overload relay product function ● overload protection Yes ● phase failure detection Yes ● asymmetry detection Yes ● ground fault detection Yes ● test function Yes ● external reset Yes reset function Manual, automatic and remote trip class Class 5 / 10 / 20 (factory set) / 30 adjustable current response value current of the currentdependent overload release 50 ... 200 A make time with automatic start after power failure maximum 3s relative repeat accuracy 1% product feature protective coating on printed-circuit board Yes number of NC contacts of auxiliary contacts of overload relay 1 number of NO contacts of auxiliary contacts of overload relay 1 operational current of auxiliary contacts of overload relay ● at AC at 600 V 5A ● at DC at 250 V 1A contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 1A@250VDC (R300) insulation voltage ● with single-phase operation at AC rated value 600 V ● with multi-phase operation at AC rated value 300 V Disconnect Switch response value of switch disconnector 200A / 600V design of fuse holder non-fusible operating class of the fuse link non-fusible Enclosure degree of protection NEMA rating 1 design of the housing Indoor general purpose use Mounting/wiring mounting position vertical fastening method Surface mounting and installation type of electrical connection for supply voltage line-side Box lug tightening torque [lbf·in] for supply 275 ... 275 lbf·in temperature of the conductor for supply maximum permissible 75 °C material of the conductor for supply AL or CU type of electrical connection for load-side outgoing feeder Box lug tightening torque [lbf·in] for load-side outgoing feeder 200 ... 200 lbf·in type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multistranded 1x (6 AWG ... 250 MCM) temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C material of the conductor for load-side outgoing feeder CU type of electrical connection of magnet coil Screw-type terminals US2:17JUH92BD Page 2/3 1.14.2021 Subject to change without notice © Copyright Siemens tightening torque [lbf·in] at magnet coil 5 ... 12 lbf·in type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 ... 12 AWG) temperature of the conductor at magnet coil maximum permissible 75 °C material of the conductor at magnet coil CU type of electrical connection for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at contactor for auxiliary contacts 10 ... 15 lbf·in type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multistranded 1x (12 AWG), 2x (16 ... 14 AWG), 2x (18 ... 16 AWG) temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C material of the conductor at contactor for auxiliary contacts CU type of electrical connection at overload relay for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at overload relay for auxiliary contacts 7 ... 10 lbf·in type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multistranded 2x (20 ... 14 AWG) temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C material of the conductor at overload relay for auxiliary contacts CU Short-circuit current rating design of the fuse link for short-circuit protection of the main circuit required 10kA@600V (Class H or K); 100kA@600V (Class R or J) certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14 Further information Industrial Controls - Product Overview (Catalogs, Brochures,…) www.usa.siemens.com/iccatalog Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:17JUH92BD Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/US/en/ps/US2:17JUH92BD Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:17JUH92BD&lang=en Certificates/approvals https://support.industry.siemens.com/cs/US/en/ps/US2:17JUH92BD/certificate US2:17JUH92BD Page 3/4 1.14.2021 Subject to change without notice © Copyright Siemens US2:17JUH92BD Page 4/5 1.14.2021 Subject to change without notice © Copyright Siemens last modified: US2:17JUH92BD Page 5/5 3/10/2020 1.14.2021 Subject to change without notice © Copyright Siemens
17JUH92BD 价格&库存

很抱歉,暂时无法提供与“17JUH92BD”相匹配的价格&库存,您可以联系我们找货

免费人工找货