Data sheet
US2:18GUG82WD
Non-reversing motor starter Size 2 1/2 Three phase full voltage Solid-state
overload relay OLRelay amp range 25-100A 208VAC 60HZ coil
Combination type 100A circuit breaker Encl NEMA type 4X 304 S-steel
Water/dust tight noncorrosive Extra-wide enclosure
product brand name
Class 18 & 26
design of the product
Full-voltage non-reversing motor starter with motor circuit protector
special product feature
ESP200 overload relay; Half-size controller
General technical data
Height x Width x Depth [in]
36 × 24 × 8 in
touch protection against electrical shock
NA for enclosed products
installation altitude [ft] at height above sea level maximum
6560 ft
ambient temperature [°F]
● during storage
-22 ... +149 °F
● during operation
-4 ... +104 °F
ambient temperature
● during storage
-30 ... +65 °C
● during operation
-20 ... +40 °C
Horsepower ratings
yielded mechanical performance [hp] for 3-phase AC
motor
● at 200/208 V rated value
15 hp
● at 220/230 V rated value
20 hp
● at 460/480 V rated value
30 hp
● at 575/600 V rated value
30 hp
Contactor
size of contactor
Controller half size 2 1/2
number of NO contacts for main contacts
3
operating voltage for main current circuit at AC at 60 Hz
maximum
600 V
operational current at AC at 600 V rated value
60 A
mechanical service life (switching cycles) of the main
contacts typical
10000000
Auxiliary contact
number of NC contacts at contactor for auxiliary contacts
0
number of NO contacts at contactor for auxiliary contacts
1
number of total auxiliary contacts maximum
7
contact rating of auxiliary contacts of contactor according
to UL
10A@600VAC (A600), 5A@600VDC (P600)
Coil
type of voltage of the control supply voltage
AC
control supply voltage
US2:18GUG82WD
Page 1/2
1.14.2021
Subject to change without notice
© Copyright Siemens
● at AC at 60 Hz rated value
208 V
holding power at AC minimum
8.6 W
apparent pick-up power of magnet coil at AC
218 V·A
apparent holding power of magnet coil at AC
25 V·A
operating range factor control supply voltage rated value
of magnet coil
0.85 ... 1.1
percental drop-out voltage of magnet coil related to the
input voltage
50 %
switch ON delay time
19 ... 29 ms
OFF delay time
10 ... 24 ms
Overload relay
reset function
Manual, automatic and remote
trip class
Class 5 / 10 / 20 (factory set) / 30
adjustable current response value current of the currentdependent overload release
25 ... 100 A
make time with automatic start after power failure
maximum
3s
relative repeat accuracy
1%
number of NC contacts of auxiliary contacts of overload
relay
1
number of NO contacts of auxiliary contacts of overload
relay
1
operational current of auxiliary contacts of overload relay
● at AC at 600 V
5A
● at DC at 250 V
1A
contact rating of auxiliary contacts of overload relay
according to UL
5A@600VAC (B600), 1A@250VDC (R300)
insulation voltage
● with single-phase operation at AC rated value
600 V
● with multi-phase operation at AC rated value
300 V
Enclosure
degree of protection NEMA rating
4X, 304 stainless steel
design of the housing
Dust-tight, watertight & corrosion resistant
Circuit Breaker
type of the motor protection
Motor circuit protector (magnetic trip only)
operational current of motor circuit breaker rated value
100 A
adjustable current response value current of
instantaneous short-circuit trip unit
315 ... 1000 A
Mounting/wiring
mounting position
Vertical
fastening method
Surface mounting and installation
type of electrical connection for supply voltage line-side
Box lug
type of connectable conductor cross-sections at line-side
at AWG cables single or multi-stranded
1x (10 AWG ... 1/0 AWG)
temperature of the conductor for supply maximum
permissible
75 °C
material of the conductor for supply
AL or CU
type of electrical connection for load-side outgoing feeder
Box lug
tightening torque [lbf·in] for load-side outgoing feeder
45 ... 45 lbf·in
type of connectable conductor cross-sections at AWG
cables for load-side outgoing feeder single or multistranded
1x (14 ... 2 AWG)
temperature of the conductor for load-side outgoing feeder
maximum permissible
75 °C
material of the conductor for load-side outgoing feeder
AL or CU
type of electrical connection of magnet coil
Screw-type terminals
tightening torque [lbf·in] at magnet coil
5 ... 12 lbf·in
type of connectable conductor cross-sections of magnet
coil at AWG cables single or multi-stranded
2x (16 ... 12 AWG)
temperature of the conductor at magnet coil maximum
permissible
75 °C
US2:18GUG82WD
Page 2/3
1.14.2021
Subject to change without notice
© Copyright Siemens
material of the conductor at magnet coil
CU
type of electrical connection for auxiliary contacts
Screw-type terminals
tightening torque [lbf·in] at contactor for auxiliary contacts
10 ... 15 lbf·in
type of connectable conductor cross-sections at contactor
at AWG cables for auxiliary contacts single or multistranded
1x (12 AWG), 2x (16 ... 14 AWG), 2x (18 ... 16 AWG)
temperature of the conductor at contactor for auxiliary
contacts maximum permissible
75 °C
material of the conductor at contactor for auxiliary contacts
CU
type of electrical connection at overload relay for auxiliary
contacts
Screw-type terminals
tightening torque [lbf·in] at overload relay for auxiliary
contacts
7 ... 10 lbf·in
type of connectable conductor cross-sections at overload
relay at AWG cables for auxiliary contacts single or multistranded
2x (20 ... 14 AWG)
temperature of the conductor at overload relay for auxiliary
contacts maximum permissible
75 °C
material of the conductor at overload relay for auxiliary
contacts
CU
Short-circuit current rating
design of the short-circuit trip
Instantaneous trip circuit breaker
breaking capacity maximum short-circuit current (Icu)
● at 240 V
100 kA
● at 480 V
100 kA
● at 600 V
25 kA
certificate of suitability
NEMA ICS 2; UL 508; CSA 22.2, No.14
Further information
Industrial Controls - Product Overview (Catalogs, Brochures,…)
www.usa.siemens.com/iccatalog
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:18GUG82WD
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/US/en/ps/US2:18GUG82WD
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:18GUG82WD&lang=en
Certificates/approvals
https://support.industry.siemens.com/cs/US/en/ps/US2:18GUG82WD/certificate
US2:18GUG82WD
Page 3/4
1.14.2021
Subject to change without notice
© Copyright Siemens
US2:18GUG82WD
Page 4/5
1.14.2021
Subject to change without notice
© Copyright Siemens
last modified:
US2:18GUG82WD
Page 5/5
3/10/2020
1.14.2021
Subject to change without notice
© Copyright Siemens
很抱歉,暂时无法提供与“18GUG82WD”相匹配的价格&库存,您可以联系我们找货