18HUG82NE

18HUG82NE

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    STARTER,COMBO SZ3,25-100AMPS,N12

  • 数据手册
  • 价格&库存
18HUG82NE 数据手册
Data sheet US2:18HUG82NE Non-reversing motor starter Size 3 Three phase full voltage Solid-state overload relay OLRelay amp range 25-100A 550/575-600 50/60HZ coil Combination type 125Amp circuit breaker Enclosure NEMA type 4/12 Water/dust tight for outdoors Extra-wide enclosure product brand name Class 18 & 26 design of the product Full-voltage non-reversing motor starter with motor circuit protector special product feature ESP200 overload relay General technical data Height x Width x Depth [in] 36 × 24 × 8 in touch protection against electrical shock NA for enclosed products installation altitude [ft] at height above sea level maximum 6560 ft ambient temperature [°F] ● during storage -22 ... +149 °F ● during operation -4 ... +104 °F ambient temperature ● during storage -30 ... +65 °C ● during operation -20 ... +40 °C Horsepower ratings yielded mechanical performance [hp] for 3-phase AC motor ● at 200/208 V rated value 25 hp ● at 220/230 V rated value 30 hp ● at 460/480 V rated value 50 hp ● at 575/600 V rated value 50 hp Contactor size of contactor NEMA controller size 3 number of NO contacts for main contacts 3 operating voltage for main current circuit at AC at 60 Hz maximum 600 V operational current at AC at 600 V rated value 90 A mechanical service life (switching cycles) of the main contacts typical 5000000 Auxiliary contact number of NC contacts at contactor for auxiliary contacts 0 number of NO contacts at contactor for auxiliary contacts 1 number of total auxiliary contacts maximum 7 contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600) Coil type of voltage of the control supply voltage AC control supply voltage US2:18HUG82NE Page 1/2 1.14.2021 Subject to change without notice © Copyright Siemens ● at AC at 50 Hz rated value 550 V ● at AC at 60 Hz rated value 575 ... 600 V holding power at AC minimum 14 W apparent pick-up power of magnet coil at AC 310 V·A apparent holding power of magnet coil at AC 26 V·A operating range factor control supply voltage rated value of magnet coil 0.85 ... 1.1 percental drop-out voltage of magnet coil related to the input voltage 50 % switch ON delay time 26 ... 41 ms OFF delay time 14 ... 19 ms Overload relay product function ● overload protection Yes ● phase failure detection Yes ● asymmetry detection Yes ● ground fault detection Yes ● test function Yes ● external reset Yes reset function Manual, automatic and remote trip class Class 5 / 10 / 20 (factory set) / 30 adjustable current response value current of the currentdependent overload release 25 ... 100 A make time with automatic start after power failure maximum 3s relative repeat accuracy 1% product feature protective coating on printed-circuit board Yes number of NC contacts of auxiliary contacts of overload relay 1 number of NO contacts of auxiliary contacts of overload relay 1 operational current of auxiliary contacts of overload relay ● at AC at 600 V 5A ● at DC at 250 V 1A contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 1A@250VDC (R300) insulation voltage ● with single-phase operation at AC rated value 600 V ● with multi-phase operation at AC rated value 300 V Enclosure degree of protection NEMA rating 4, 12 design of the housing Dust-tight, watertight & weather proof Circuit Breaker type of the motor protection Motor circuit protector (magnetic trip only) operational current of motor circuit breaker rated value 125 A adjustable current response value current of instantaneous short-circuit trip unit 500 ... 1250 A Mounting/wiring mounting position Vertical fastening method Surface mounting and installation type of electrical connection for supply voltage line-side Box lug type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 1x (10 AWG ... 1/0 AWG) temperature of the conductor for supply maximum permissible 75 °C material of the conductor for supply AL or CU type of electrical connection for load-side outgoing feeder Box lug tightening torque [lbf·in] for load-side outgoing feeder 120 ... 120 lbf·in type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multistranded 1x (14 ... 2/0 AWG) US2:18HUG82NE Page 2/3 1.14.2021 Subject to change without notice © Copyright Siemens temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C material of the conductor for load-side outgoing feeder AL or CU type of electrical connection of magnet coil Screw-type terminals tightening torque [lbf·in] at magnet coil 5 ... 12 lbf·in type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 ... 12 AWG) temperature of the conductor at magnet coil maximum permissible 75 °C material of the conductor at magnet coil CU type of electrical connection for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at contactor for auxiliary contacts 10 ... 15 lbf·in type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multistranded 1x (12 AWG), 2x (16 ... 14 AWG), 2x (18 ... 16 AWG) temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C material of the conductor at contactor for auxiliary contacts CU type of electrical connection at overload relay for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at overload relay for auxiliary contacts 7 ... 10 lbf·in type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multistranded 2x (20 ... 14 AWG) temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C material of the conductor at overload relay for auxiliary contacts CU Short-circuit current rating design of the short-circuit trip Instantaneous trip circuit breaker breaking capacity maximum short-circuit current (Icu) ● at 240 V 100 kA ● at 480 V 100 kA ● at 600 V 25 kA certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14 Further information Industrial Controls - Product Overview (Catalogs, Brochures,…) www.usa.siemens.com/iccatalog Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:18HUG82NE Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/US/en/ps/US2:18HUG82NE Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:18HUG82NE&lang=en Certificates/approvals https://support.industry.siemens.com/cs/US/en/ps/US2:18HUG82NE/certificate US2:18HUG82NE Page 3/4 1.14.2021 Subject to change without notice © Copyright Siemens US2:18HUG82NE Page 4/5 1.14.2021 Subject to change without notice © Copyright Siemens last modified: US2:18HUG82NE Page 5/5 3/10/2020 1.14.2021 Subject to change without notice © Copyright Siemens
18HUG82NE 价格&库存

很抱歉,暂时无法提供与“18HUG82NE”相匹配的价格&库存,您可以联系我们找货

免费人工找货