0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RA21150JA151AK6

3RA21150JA151AK6

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    STARTER DOL S00 0.7-1A 120VAC SC

  • 数据手册
  • 价格&库存
3RA21150JA151AK6 数据手册
Data sheet 3RA2115-0JA15-1AK6 Fuseless motor starter Direct start 600VAC Size S00 0.7-1A 110/120VAC 50/60HZ screw connection For screw mounting Or 35 mm rail-mounting Type of coordination 2 IQ = 150 KA Also full fills type Of coordination 1 1NO+1NC (MSP) 1NO (contactor) product brand name SIRIUS product designation non-fused motor starter 3RA2 design of the product direct starter manufacturer's article number ● of the supplied contactor 3RT2015-1AK61 ● of the supplied circuit-breakers 3RV2011-0JA15 ● of the supplied link module 3RA1921-1DA00 General technical data size of the circuit-breaker S00 size of load feeder S00 product extension auxiliary switch Yes insulation voltage with degree of pollution 3 at AC rated value 690 V degree of pollution 3 surge voltage resistance rated value 6 kV shock resistance according to IEC 60068-2-27 6g / 11 ms mechanical service life (switching cycles) of contactor typical 30 000 000 type of assignment 2 Ambient conditions ambient temperature ● during operation -20 ... +60 °C ● during storage -50 ... +80 °C ● during transport -55 ... +80 °C Main circuit number of poles for main current circuit 3 design of the switching contact electromechanical adjustable current response value current of the current-dependent overload release 0.7 ... 1 A operating voltage ● rated value 690 V ● at AC-3 rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current at AC-3 at 400 V rated value 0.85 A operating power at AC-3 ● at 400 V rated value 250 W ● at 500 V rated value 370 W ● at 690 V rated value 550 W Control circuit/ Control control supply voltage at AC 3RA21150JA151AK6 Page 1/3 7/9/2022 Subject to change without notice © Copyright Siemens ● at 50 Hz rated value 110 V ● at 50 Hz rated value 93.5 ... 121 V ● at 60 Hz rated value 120 V ● at 60 Hz rated value 96 ... 132 V apparent holding power of magnet coil at AC 4.8 VA inductive power factor with the holding power of the coil 0.25 Auxiliary circuit number of NC contacts for auxiliary contacts 1 number of NO contacts for auxiliary contacts 2 Protective and monitoring functions trip class CLASS 10 design of the overload release thermal (bimetallic) response value current of instantaneous short-circuit trip unit 13 A UL/CSA ratings yielded mechanical performance [hp] ● for 3-phase AC motor — at 575/600 V rated value 0.5 hp Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic conditional short-circuit current (Iq) ● at 690 V according to IEC 60947-4-1 rated value 100 000 A ● at 400 V according to IEC 60947-4-1 rated value 153 000 A ● at 500 V according to IEC 60947-4-1 rated value 100 000 A Installation/ mounting/ dimensions mounting position vertical fastening method Snap-mounted to DIN rail or screw-mounted with additional push-in lug height 167.2 mm width 45 mm depth 97.1 mm required spacing ● for grounded parts — forwards 0 mm — backwards 0 mm — upwards 20 mm — at the side 9 mm — downwards 10 mm ● for live parts — forwards 0 mm — backwards 0 mm — upwards 20 mm — downwards 10 mm — at the side 9 mm Connections/ Terminals type of electrical connection for main current circuit screw-type terminals type of connectable conductor cross-sections ● for main contacts stranded 0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²) ● at AWG cables for main contacts 2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12 connectable conductor cross-section for main contacts finely stranded with core end processing 0.5 ... 2.5 mm² Safety related data B10 value with high demand rate according to SN 31920 1 000 000 proportion of dangerous failures with high demand rate according to SN 31920 73 % protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front Certificates/ approvals 3RA21150JA151AK6 Page 2/3 7/9/2022 Subject to change without notice © Copyright Siemens General Product Approval For use in hazardous locations Declaration of Conformity other Railway Confirmation Declaration of Conformity Test Certificates Type Test Certificates/Test Report Marine / Shipping Special Test Certificate Marine / Shipping Confirmation Vibration and Shock Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RA2115-0JA15-1AK6 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RA2115-0JA15-1AK6 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RA2115-0JA15-1AK6 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RA2115-0JA15-1AK6&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RA2115-0JA15-1AK6/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RA2115-0JA15-1AK6&objecttype=14&gridview=view1 last modified: 3RA21150JA151AK6 Page 3/3 12/15/2020 7/9/2022 Subject to change without notice © Copyright Siemens
3RA21150JA151AK6 价格&库存

很抱歉,暂时无法提供与“3RA21150JA151AK6”相匹配的价格&库存,您可以联系我们找货

免费人工找货