0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RB2153-4FC2

3RB2153-4FC2

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    电子式过载继电器 电机保护

  • 数据手册
  • 价格&库存
3RB2153-4FC2 数据手册
Data sheet 3RB2153-4FC2 Overload relay 50...200 A for motor protection Size S6, CLASS 5...30E Contactor mounting/stand-alone installation Main circuit: busbar connection Auxiliary circuit: Screw terminal Manual-Automatic-Reset Internal ground fault detection product brand name SIRIUS product designation solid-state overload relay product type designation 3RB2 General technical data size of overload relay S6 size of contactor can be combined company-specific S6 insulation voltage with degree of pollution 3 at AC rated value 1 000 V surge voltage resistance rated value 8 kV maximum permissible voltage for safe isolation in networks with grounded star point ● between auxiliary and auxiliary circuit 300 V ● between auxiliary and auxiliary circuit 300 V ● between main and auxiliary circuit 600 V ● between main and auxiliary circuit 690 V shock resistance ● according to IEC 60068-2-27 15g / 11 ms 15g / 11 ms vibration resistance 1-6 Hz, 15 mm; 6-500 Hz, 20 m/s²; 10 cycles thermal current 200 A type of protection according to ATEX directive 2014/34/EU Ex II (2) G [Ex e] [Ex d] [Ex px] ; Ex II (2) D [Ex t] [Ex p] certificate of suitability according to ATEX directive 2014/34/EU PTB 06 ATEX 3001 reference code according to IEC 81346-2 F Substance Prohibitance (Date) 07/01/2006 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -25 ... +60 °C ● during storage -40 ... +80 °C ● during transport -40 ... +80 °C temperature compensation -25 ... +60 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3 adjustable current response value current of the current-dependent overload release 50 ... 200 A operating voltage ● rated value 1 000 V ● for remote-reset function at DC 24 V 3RB21534FC2 Page 1/4 7/4/2022 Subject to change without notice © Copyright Siemens ● at AC-3e rated value maximum 1 000 V operating frequency rated value 50 ... 60 Hz operational current rated value 200 A operational current at AC-3e at 400 V rated value 200 A operating power ● for 3-phase motors at 400 V at 50 Hz 30 ... 90 kW ● for AC motors at 500 V at 50 Hz 30 ... 132 kW ● for AC motors at 690 V at 50 Hz 55 ... 160 kW Auxiliary circuit design of the auxiliary switch integrated number of NC contacts for auxiliary contacts 1 ● note number of NO contacts for auxiliary contacts ● note number of CO contacts for auxiliary contacts for contactor disconnection 1 for message "tripped" 0 operational current of auxiliary contacts at AC-15 ● at 24 V 4A ● at 110 V 4A ● at 120 V 4A ● at 125 V 4A ● at 230 V 3A operational current of auxiliary contacts at DC-13 ● at 24 V 2A ● at 60 V 0.55 A ● at 110 V 0.3 A ● at 125 V 0.3 A ● at 220 V 0.11 A Protective and monitoring functions trip class CLASS 5E, 10E, 20E and 30E adjustable design of the overload release electronic response value current of the grounding protection minimum 0.75 x IMotor response time of the grounding protection in settled state 1 000 ms operating range of the grounding protection relating to current set value ● minimum IMotor > lower current setting value ● maximum IMotor < upper current setting value x 3.5 UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 200 A ● at 600 V rated value 200 A contact rating of auxiliary contacts according to UL B600 / R300 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 355 A, Class L: 601 A — with type of assignment 2 required gG: 315 A ● for short-circuit protection of the auxiliary switch required fuse gG: 6 A Installation/ mounting/ dimensions mounting position any fastening method Contactor mounting/stand-alone installation height 119 mm width 120 mm depth 155 mm Connections/ Terminals product component removable terminal for auxiliary and control circuit Yes type of electrical connection 3RB21534FC2 Page 2/4 7/4/2022 Subject to change without notice © Copyright Siemens ● for main current circuit busbar connection ● for auxiliary and control circuit screw-type terminals arrangement of electrical connectors for main current circuit Top and bottom type of connectable conductor cross-sections ● for auxiliary contacts — solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) — solid or stranded 1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²) — finely stranded with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) ● at AWG cables for auxiliary contacts 2x (20 ... 14) tightening torque ● for main contacts with screw-type terminals 10 ... 12 N·m ● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m design of the thread of the connection screw ● for main contacts M10 ● of the auxiliary and control contacts M3 Safety related data protection class IP on the front according to IEC 60529 IP00; IP20 with box terminal/cover touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front with box terminal/cover Communication/ Protocol type of voltage supply via input/output link master No Electromagnetic compatibility conducted interference ● due to burst according to IEC 61000-4-4 2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3 ● due to conductor-earth surge according to IEC 61000-4-5 2 kV (line to earth) corresponds to degree of severity 3 ● due to conductor-conductor surge according to IEC 61000-4-5 1 kV (line to line) corresponds to degree of severity 3 ● due to high-frequency radiation according to IEC 61000-4-6 10 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz field-based interference according to IEC 61000-4-3 10 V/m electrostatic discharge according to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge Display display version for switching status Slide switch Certificates/ approvals General Product Approval EMC Confirmation For use in hazardous locations Declaration of Conformity Test Certificates Special Test Certificate Marine / Shipping Marine / Shipping Type Test Certificates/Test Report other Confirmation 3RB21534FC2 Page 3/4 7/4/2022 Miscellaneous Subject to change without notice © Copyright Siemens Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RB2153-4FC2 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RB2153-4FC2 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RB2153-4FC2 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RB2153-4FC2&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RB2153-4FC2/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RB2153-4FC2&objecttype=14&gridview=view1 last modified: 2/9/2022 3RB21534FC2 Page 4/4 7/4/2022 Subject to change without notice © Copyright Siemens
3RB2153-4FC2 价格&库存

很抱歉,暂时无法提供与“3RB2153-4FC2”相匹配的价格&库存,您可以联系我们找货

免费人工找货