3RB30161SB0

3RB30161SB0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 3RB30161SB0 - Electronic Overload Controller, 3 A, 12 A, SIRIUS 3RB3

  • 数据手册
  • 价格&库存
3RB30161SB0 数据手册
Data sheet 3RB3016-1SB0 Overload relay 3...12 A Electronic For motor protection Size S00, Class 10E Contactor mounting Main circuit: Screw Auxiliary circuit: Screw Manual-AutomaticReset product brand name SIRIUS product designation solid-state overload relay product type designation 3RB3 General technical data size of overload relay S00 size of contactor can be combined company-specific S00 power loss [W] for rated value of the current at AC in hot operating state 0.6 W ● per pole 0.2 W insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV maximum permissible voltage for protective separation in networks with grounded star point ● between auxiliary and auxiliary circuit 300 V ● between auxiliary and auxiliary circuit 300 V ● between main and auxiliary circuit 600 V ● between main and auxiliary circuit 690 V shock resistance ● according to IEC 60068-2-27 15g / 11 ms 15g / 11 ms; Signaling contact 97 / 98 in position "Tripped": 9g / 11 ms thermal current 12 A reference code according to IEC 81346-2 F Substance Prohibitance (Date) 10/01/2009 SVHC substance name Lead monoxide (lead oxide) - 1317-36-8 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -25 ... +60 °C ● during storage -40 ... +80 °C ● during transport -40 ... +80 °C temperature compensation -25 ... +60 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3 adjustable current response value current of the currentdependent overload release 3 ... 12 A operating voltage ● rated value 690 V ● at AC-3e rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current rated value 12 A operational current at AC-3e at 400 V rated value 12 A 3RB30161SB0 Page 1/5 4/29/2024 Subject to change without notice © Copyright Siemens operating power ● for 3-phase motors at 400 V at 50 Hz 1.5 ... 5.5 kW ● for AC motors at 500 V at 50 Hz 1.5 ... 5.5 kW ● for AC motors at 690 V at 50 Hz 2.2 ... 7.5 kW Auxiliary circuit design of the auxiliary switch integrated number of NC contacts for auxiliary contacts 1 ● note number of NO contacts for auxiliary contacts ● note number of CO contacts for auxiliary contacts for contactor disconnection 1 for message "tripped" 0 operational current of auxiliary contacts at AC-15 ● at 24 V 4A ● at 110 V 4A ● at 120 V 4A ● at 125 V 4A ● at 230 V 3A operational current of auxiliary contacts at DC-13 ● at 24 V 2A ● at 60 V 0.55 A ● at 110 V 0.3 A ● at 125 V 0.3 A ● at 220 V 0.11 A Protective and monitoring functions trip class CLASS 10E design of the overload release electronic UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 12 A ● at 600 V rated value 12 A contact rating of auxiliary contacts according to UL B600 / R300 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 50 A, RK5: 45 A — with type of assignment 2 required gG: 50 A, J: 45 A ● for short-circuit protection of the auxiliary switch required fuse gG: 6 A Installation/ mounting/ dimensions mounting position any fastening method Contactor mounting height 79 mm width 45 mm depth 73 mm Connections/ Terminals product component removable terminal for auxiliary and control circuit Yes type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit screw-type terminals arrangement of electrical connectors for main current circuit Top and bottom type of connectable conductor cross-sections for main contacts ● solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 4 mm²) ● solid or stranded 1x (0,5 ... 4 mm²), 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 4 mm²) ● finely stranded with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 2.5 mm²) type of connectable conductor cross-sections ● for auxiliary contacts — solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) — solid or stranded 1x (0,5 ... 4 mm²), 2x (0,5 ... 2,5 mm²) — finely stranded with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) ● for AWG cables for auxiliary contacts 3RB30161SB0 Page 2/5 1x (20 ... 14), 2x (20 ... 14) 4/29/2024 Subject to change without notice © Copyright Siemens tightening torque ● for main contacts with screw-type terminals 0.8 ... 1.2 N·m ● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m design of screwdriver shaft Diameter 5 to 6 mm size of the screwdriver tip Pozidriv PZ 2 design of the thread of the connection screw ● for main contacts M3 ● of the auxiliary and control contacts M3 Electrical Safety protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front Communication/ Protocol type of voltage supply via input/output link master No Electromagnetic compatibility conducted interference ● due to burst according to IEC 61000-4-4 2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3 ● due to conductor-earth surge according to IEC 61000-4-5 2 kV (line to earth) corresponds to degree of severity 3 ● due to conductor-conductor surge according to IEC 61000-4-5 1 kV (line to line) corresponds to degree of severity 3 ● due to high-frequency radiation according to IEC 610004-6 10 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz field-based interference according to IEC 61000-4-3 10 V/m electrostatic discharge according to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge Display display version for switching status Slide switch Approvals Certificates General Product Approval Confirmation General Product Approval For use in hazardous locations EMV KC Test Certificates Special Test Certificate Type Test Certificates/Test Report Marine / Shipping other Confirmation Environment Environmental Confirmations Further information Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RB3016-1SB0 3RB30161SB0 Page 3/5 4/29/2024 Subject to change without notice © Copyright Siemens Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RB3016-1SB0 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RB3016-1SB0 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RB3016-1SB0&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RB3016-1SB0/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RB3016-1SB0&objecttype=14&gridview=view1 3RB30161SB0 Page 4/5 4/29/2024 Subject to change without notice © Copyright Siemens 95 NC 97 NO 96 NC 98 NO RESET TEST 6/T3 4/T2 2/T1 -F last modified: 3/11/2024 3RB30161SB0 Page 5/5 4/29/2024 Subject to change without notice © Copyright Siemens
3RB30161SB0 价格&库存

很抱歉,暂时无法提供与“3RB30161SB0”相匹配的价格&库存,您可以联系我们找货

免费人工找货