Data sheet
3RB3026-1VE0
Overload relay 10...40 A Electronic For motor protection Size S0, Class 10E
Contactor mounting Main circuit: Spring-type terminal Auxiliary circuit: Spring-type
terminal Manual-Automatic-Reset
product brand name
SIRIUS
product designation
solid-state overload relay
product type designation
3RB3
General technical data
size of overload relay
S0
size of contactor can be combined company-specific
S0
power loss [W] for rated value of the current at AC in hot
operating state
4.5 W
● per pole
1.5 W
insulation voltage with degree of pollution 3 at AC rated value
690 V
surge voltage resistance rated value
6 kV
maximum permissible voltage for protective separation in
networks with grounded star point
● between auxiliary and auxiliary circuit
300 V
● between auxiliary and auxiliary circuit
300 V
● between main and auxiliary circuit
600 V
● between main and auxiliary circuit
690 V
shock resistance
● according to IEC 60068-2-27
15g / 11 ms
15g / 11 ms; Signaling contact 97 / 98 in position "Tripped": 9g / 11 ms
thermal current
40 A
reference code according to IEC 81346-2
F
Substance Prohibitance (Date)
10/01/2009
SVHC substance name
Lead - 7439-92-1
Lead monoxide (lead oxide) - 1317-36-8
Ambient conditions
installation altitude at height above sea level maximum
2 000 m
ambient temperature
● during operation
-25 ... +60 °C
● during storage
-40 ... +80 °C
● during transport
-40 ... +80 °C
temperature compensation
-25 ... +60 °C
relative humidity during operation
10 ... 95 %
Main circuit
number of poles for main current circuit
3
adjustable current response value current of the currentdependent overload release
10 ... 40 A
operating voltage
● rated value
690 V
● at AC-3e rated value maximum
690 V
operating frequency rated value
50 ... 60 Hz
operational current rated value
40 A
3RB30261VE0
Page 1/5
5/29/2024
Subject to change without notice
© Copyright Siemens
operational current at AC-3e at 400 V rated value
40 A
operating power
● for 3-phase motors at 400 V at 50 Hz
5.5 ... 18.5 kW
● for AC motors at 500 V at 50 Hz
7.5 ... 22 kW
● for AC motors at 690 V at 50 Hz
11 ... 37 kW
Auxiliary circuit
design of the auxiliary switch
integrated
number of NC contacts for auxiliary contacts
1
● note
number of NO contacts for auxiliary contacts
● note
number of CO contacts for auxiliary contacts
for contactor disconnection
1
for message "tripped"
0
operational current of auxiliary contacts at AC-15
● at 24 V
4A
● at 110 V
4A
● at 120 V
4A
● at 125 V
4A
● at 230 V
3A
operational current of auxiliary contacts at DC-13
● at 24 V
2A
● at 60 V
0.55 A
● at 110 V
0.3 A
● at 125 V
0.3 A
● at 220 V
0.11 A
Protective and monitoring functions
trip class
CLASS 10E
design of the overload release
electronic
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value
40 A
● at 600 V rated value
40 A
contact rating of auxiliary contacts according to UL
B600 / R300
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 required
gG: 125 A, J: 150 A
— with type of assignment 2 required
gG: 80 A, J: 100 A
● for short-circuit protection of the auxiliary switch required
fuse gG: 6 A
Installation/ mounting/ dimensions
mounting position
any
fastening method
Contactor mounting
height
109 mm
width
45 mm
depth
85 mm
Connections/ Terminals
product component removable terminal for auxiliary and
control circuit
Yes
type of electrical connection
● for main current circuit
spring-loaded terminals
● for auxiliary and control circuit
spring-loaded terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections for main contacts
● solid
1x (1 ... 10 mm²)
● stranded
1x 10 mm²
● solid or stranded
1x (1 ... 10 mm²)
● finely stranded with core end processing
1x (1 ... 6 mm²)
● finely stranded without core end processing
1x (1 ... 6 mm²)
type of connectable conductor cross-sections
● for auxiliary contacts
— solid
3RB30261VE0
Page 2/5
2x (0.25 ... 1.5 mm²)
5/29/2024
Subject to change without notice
© Copyright Siemens
— solid or stranded
2x (0,25 ... 1,5 mm²)
— finely stranded with core end processing
2x (0.25 ... 1.5 mm²)
— finely stranded without core end processing
2x (0.25 ... 1.5 mm²)
● for AWG cables for auxiliary contacts
1x (24 ... 16), 2x (24 ... 16)
design of screwdriver shaft
Diameter 5 to 6 mm
size of the screwdriver tip
Pozidriv PZ 2
Electrical Safety
protection class IP on the front according to IEC 60529
IP20
touch protection on the front according to IEC 60529
finger-safe, for vertical contact from the front
Communication/ Protocol
type of voltage supply via input/output link master
No
Electromagnetic compatibility
conducted interference
● due to burst according to IEC 61000-4-4
2 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3
● due to conductor-earth surge according to IEC 61000-4-5
2 kV (line to earth) corresponds to degree of severity 3
● due to conductor-conductor surge according to IEC
61000-4-5
1 kV (line to line) corresponds to degree of severity 3
● due to high-frequency radiation according to IEC 610004-6
10 V in frequency range 0.15 to 80 MHz, modulation 80 % AM with 1 kHz
field-based interference according to IEC 61000-4-3
10 V/m
electrostatic discharge according to IEC 61000-4-2
6 kV contact discharge / 8 kV air discharge
Display
display version for switching status
Slide switch
Approvals Certificates
General Product Approval
Confirmation
For use in hazardous locations
EMV
KC
Test Certificates
Type Test Certificates/Test Report
Marine / Shipping
Marine / Shipping
Special Test Certificate
other
Environment
Confirmation
Environmental Confirmations
Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RB3026-1VE0
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RB3026-1VE0
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RB3026-1VE0
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RB3026-1VE0&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RB3026-1VE0/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RB3026-1VE0&objecttype=14&gridview=view1
3RB30261VE0
Page 3/5
5/29/2024
Subject to change without notice
© Copyright Siemens
3RB30261VE0
Page 4/5
5/29/2024
Subject to change without notice
© Copyright Siemens
95 NC
97 NO
96 NC
98 NO
RESET
TEST
6/T3
4/T2
2/T1
-F
last modified:
3/11/2024
3RB30261VE0
Page 5/5
5/29/2024
Subject to change without notice
© Copyright Siemens