3RH21404BB40

3RH21404BB40

  • 厂商:

    SIEMENS(西门子)

  • 封装:

  • 描述:

    CONTACTOR RELAY 4NO DC 24V RING

  • 数据手册
  • 价格&库存
3RH21404BB40 数据手册
Data sheet 3RH2140-4BB40 Contactor relay, 4 NO, 24 V DC, Size S00, ring cable lug connection product brand name SIRIUS product designation Auxiliary contactor product type designation 3RH2 General technical data size of contactor S00 product extension auxiliary switch Yes insulation voltage with degree of pollution 3 at AC rated value 690 V degree of pollution 3 surge voltage resistance rated value 6 kV shock resistance at rectangular impulse ● at DC 10g / 5 ms, 5g / 10 ms shock resistance with sine pulse ● at DC 15g / 5 ms, 8g / 10 ms mechanical service life (switching cycles) ● of contactor typical 30 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code acc. to IEC 81346-2 K Substance Prohibitance (Date) 01.10.2009 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -25 ... +60 °C ● ambient temperature during storage -55 ... +80 °C Main circuit no-load switching frequency ● at AC 10 000 1/h ● at DC 10 000 1/h Control circuit/ Control type of voltage of the control supply voltage DC control supply voltage at DC ● rated value 24 V operating range factor control supply voltage rated value of magnet coil at DC ● initial value 0.8 ● full-scale value 1.1 3RH21404BB40 Page 1/2 1.21.2021 Subject to change without notice © Copyright Siemens closing power of magnet coil at DC 4W holding power of magnet coil at DC 4W closing delay ● at DC 30 ... 100 ms opening delay ● at DC arcing time 7 ... 13 ms 10 ... 15 ms Auxiliary circuit number of NO contacts for auxiliary contacts ● instantaneous contact 4 4 identification number and letter for switching elements 40 E operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at 1 current path at DC-12 ● at 24 V rated value 10 A ● at 110 V rated value 3A ● at 220 V rated value 1A ● at 440 V rated value 0.3 A ● at 600 V rated value 0.15 A operational current with 2 current paths in series at DC-12 ● at 24 V rated value 10 A ● at 60 V rated value 10 A ● at 110 V rated value 4A ● at 220 V rated value 2A ● at 440 V rated value 1.3 A ● at 600 V rated value 0.65 A operational current with 3 current paths in series at DC-12 ● at 24 V rated value 10 A ● at 60 V rated value 10 A ● at 110 V rated value 10 A ● at 220 V rated value 3.6 A ● at 440 V rated value 2.5 A ● at 600 V rated value 1.8 A operating frequency at DC-12 maximum 1 000 1/h operational current at 1 current path at DC-13 ● at 24 V rated value 10 A ● at 110 V rated value 1A ● at 220 V rated value 0.3 A ● at 440 V rated value 0.14 A ● at 600 V rated value 0.1 A operational current with 2 current paths in series at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 3.5 A ● at 110 V rated value 1.3 A ● at 220 V rated value 0.9 A ● at 440 V rated value 0.2 A ● at 600 V rated value 0.1 A operational current with 3 current paths in series at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 4.7 A 3RH21404BB40 Page 2/3 1.21.2021 Subject to change without notice © Copyright Siemens ● at 110 V rated value 3A ● at 220 V rated value 1.2 A ● at 440 V rated value 0.5 A ● at 600 V rated value 0.26 A operating frequency at DC-13 maximum 1 000 1/h design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V C characteristic: 6 A; 0.4 kA contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm standard mounting rail height 57.5 mm width 45 mm depth 73 mm required spacing ● with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm ● for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection for auxiliary and control circuit ring cable connection Safety related data B10 value with high demand rate acc. to SN 31920 1 000 000; With 0.3 x Ie proportion of dangerous failures ● with low demand rate acc. to SN 31920 40 % ● with high demand rate acc. to SN 31920 73 % failure rate [FIT] with low demand rate acc. to SN 31920 100 FIT product function positively driven operation acc. to IEC 60947-5-1 Yes T1 value for proof test interval or service life acc. to IEC 61508 20 y protection class IP on the front acc. to IEC 60529 IP00 Certificates/ approvals General Product Approval EMC KC Declaration of Conformity 3RH21404BB40 Page 3/4 Test Certificates 1.21.2021 Marine / Shipping Subject to change without notice © Copyright Siemens Miscellaneous Special Test Certificate Type Test Certificates/Test Report Marine / Shipping other Confirmation other Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RH2140-4BB40 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RH2140-4BB40 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RH2140-4BB40 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RH2140-4BB40&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RH2140-4BB40/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RH2140-4BB40&objecttype=14&gridview=view1 3RH21404BB40 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens 3RH21404BB40 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens 3RH21404BB40 Page 6/7 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 1/6/2021 3RH21404BB40 Page 7/7 1.21.2021 Subject to change without notice © Copyright Siemens
3RH21404BB40 价格&库存

很抱歉,暂时无法提供与“3RH21404BB40”相匹配的价格&库存,您可以联系我们找货

免费人工找货