0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RH24221XF400LA2

3RH24221XF400LA2

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    LATCHED CONTACTOR RELAY RAIL. 2N

  • 数据手册
  • 价格&库存
3RH24221XF400LA2 数据手册
Data sheet 3RH2422-1XF40-0LA2 Contactor relay latched railway, 2 NO + 2 NC, 72..125 V DC, 0.7 ... 1.25* Us, with integr. varistor, Size S00, screw terminal Suitable for PLC outputs product brand name SIRIUS product designation Contactor relay for railway applications product type designation 3RH2 General technical data size of contactor S00 product extension auxiliary switch Yes insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV shock resistance at rectangular impulse ● at DC 10g / 5 ms, 5g / 10 ms shock resistance with sine pulse ● at DC 15g / 5 ms, 8g / 10 ms mechanical service life (switching cycles) ● of contactor typical 30 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code acc. to IEC 81346-2 K Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -40 ... +70 °C ● ambient temperature during storage -55 ... +80 °C Main circuit no-load switching frequency ● at DC 1 500 1/h Control circuit/ Control type of voltage of the control supply voltage DC control supply voltage at DC ● rated value 72 ... 125 V operating range factor control supply voltage rated value of magnet coil at DC ● initial value 0.7 ● full-scale value 1.25 design of the surge suppressor Varistor closing power of magnet coil at DC 4.5 W holding power of magnet coil at DC 0.75 W 3RH24221XF400LA2 Page 1/2 1.6.2021 Subject to change without notice © Copyright Siemens closing delay ● at DC 30 ... 70 ms opening delay ● at DC 25 ... 45 ms arcing time 10 ... 15 ms residual current of the electronics for control with signal at DC at 24 V maximum permissible 10 mA Auxiliary circuit number of NC contacts for auxiliary contacts ● instantaneous contact number of NO contacts for auxiliary contacts ● instantaneous contact 2 2 2 2 identification number and letter for switching elements 31 E operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at 1 current path at DC-12 ● at 24 V rated value 10 A ● at 110 V rated value 3A ● at 220 V rated value 1A ● at 440 V rated value 0.3 A ● at 600 V rated value 0.15 A operational current with 2 current paths in series at DC-12 ● at 24 V rated value 10 A ● at 60 V rated value 10 A ● at 110 V rated value 4A ● at 220 V rated value 2A ● at 440 V rated value 1.3 A ● at 600 V rated value 0.65 A operational current with 3 current paths in series at DC-12 ● at 24 V rated value 10 A ● at 60 V rated value 10 A ● at 110 V rated value 10 A ● at 220 V rated value 3.6 A ● at 440 V rated value 2.5 A ● at 600 V rated value 1.8 A operating frequency at DC-12 maximum 1 000 1/h operational current at 1 current path at DC-13 ● at 24 V rated value 10 A ● at 110 V rated value 1A ● at 220 V rated value 0.3 A ● at 440 V rated value 0.14 A ● at 600 V rated value 0.1 A operational current with 2 current paths in series at DC-13 ● at 24 V rated value 10 A ● at 60 V rated value 3.5 A ● at 110 V rated value 1.3 A ● at 220 V rated value 0.9 A ● at 440 V rated value 0.2 A ● at 600 V rated value 0.1 A operational current with 3 current paths in series at DC-13 ● at 24 V rated value 3RH24221XF400LA2 Page 2/3 10 A 1.6.2021 Subject to change without notice © Copyright Siemens ● at 60 V rated value 4.7 A ● at 110 V rated value 3A ● at 220 V rated value 1.2 A ● at 440 V rated value 0.5 A ● at 600 V rated value 0.26 A operating frequency at DC-13 maximum 1 000 1/h design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V C characteristic: 6 A; 0.4 kA contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link for short-circuit protection of the auxiliary switch required fuse gL/gG: 10 A Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface, can be tilted forward and backward by +/- 22.5° on vertical mounting surface, standing, on horizontal mounting surface fastening method screw and snap-on mounting onto 35 mm standard mounting rail ● side-by-side mounting Yes height 58 mm width 90 mm depth 73 mm required spacing ● with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm ● for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection for auxiliary and control circuit screw-type terminals connectable conductor cross-section for auxiliary contacts ● solid or stranded 0.5 ... 4 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm² — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12 ● AWG number as coded connectable conductor cross section for auxiliary contacts 20 ... 12 Safety related data B10 value with high demand rate acc. to SN 31920 1 000 000 proportion of dangerous failures ● with low demand rate acc. to SN 31920 40 % ● with high demand rate acc. to SN 31920 73 % product function positively driven operation acc. to IEC 60947-5-1 3RH24221XF400LA2 Page 3/4 Yes 1.6.2021 Subject to change without notice © Copyright Siemens T1 value for proof test interval or service life acc. to IEC 61508 20 y Certificates/ approvals General Product Approval Declaration of Conformity EMC KC Declaration of Conformity Miscellaneous Test Certificates Special Test Certificate Marine / Shipping Special Test Certificate Type Test Certificates/Test Report Marine / Shipping other Confirmation other Railway Special Test Certificate Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RH2422-1XF40-0LA2 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RH2422-1XF40-0LA2 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RH2422-1XF40-0LA2 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RH2422-1XF40-0LA2&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RH2422-1XF40-0LA2/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RH2422-1XF40-0LA2&objecttype=14&gridview=view1 3RH24221XF400LA2 Page 4/5 1.6.2021 Subject to change without notice © Copyright Siemens 3RH24221XF400LA2 Page 5/6 1.6.2021 Subject to change without notice © Copyright Siemens 3RH24221XF400LA2 Page 6/7 1.6.2021 Subject to change without notice © Copyright Siemens last modified: 3RH24221XF400LA2 Page 7/7 12/15/2020 1.6.2021 Subject to change without notice © Copyright Siemens
3RH24221XF400LA2 价格&库存

很抱歉,暂时无法提供与“3RH24221XF400LA2”相匹配的价格&库存,您可以联系我们找货

免费人工找货