3RP15051BP30

3RP15051BP30

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 3RP15051BP30 - Time Delay Relay, 24 VDC, 5 s, 100 h, 3RP1, DPDT, 3 A

  • 详情介绍
  • 数据手册
  • 价格&库存
3RP15051BP30 数据手册
Product data sheet 3RP1505-1BP30 TIME RELAY, MULTI-FUNCTION 2 CHANGEOVER, 16 FUNCTIONS, 15 TIME SETTING RANGES AC 24/200... 240 V AND DC 24V, WITH LED, SCREW CONNECTION General technical data: product brand name SIRIUS product designation timing relay Protection class IP / on the front IP40 Protection class IP / of the terminal IP20 mounting position any Supply voltage frequency • 1 / for auxiliary and control current circuit • initial rated value Hz 50 • final rated value Hz 60 Product function • star-delta circuit Yes • with auxiliary voltage / pulse-shaping Yes • at the relay outputs / changeover delayed/without delay Yes Product component / semi-conductor output No Product extension / optional / remote control No Product extension / strictly required / remote control No Installation altitude / at a height over sea level / maximum m 2,000 °C -40 … +85 Ambient temperature • during storage 3RP1505-1BP30 Page 1/ 6 11/18/2013 subject to modifications © Copyright Siemens AG 2013 • during operating °C -25 … +60 • during transport °C -40 … +85 % 15 … 70 Relative humidity • during operating phase Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 2 kV network connection / 1 kV control connection Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 2 kV Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 1 kV Electrostatic discharge / according to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge Field-bound parasitic coupling / according to IEC 61000-4-3 10 V/m Resistance against vibration 10 ... 55 Hz / 0.35 mm Impulse voltage resistance / rated value V 4,000 Insulation voltage / rated value V 300 Active power loss / total / typical W 2 Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 K Item designation / according to DIN EN 61346-2 K Category / according to EN 954-1 none Protection against electrical shock finger-safe Switching Function: Switching function • slow-operating Yes • making pulse contact No • firmly clocked beginning with pulse No • firmly clocked beginning with pause Yes • relapse delayed Yes • variably clocked start with impulse No • impuls variably clocked start with pause No • with auxiliary voltage • in an additive way slow-operating Yes • temporary line fault Yes • relapse delayed Yes • without auxiliary voltage / relapse delayed No • slow-operating/instantaneous contact Yes • with auxiliary voltage • relapse delayed/instantaneous contact Yes • slow-operating/relapse delayed/instantaneous contact Yes • firmly clocked beginning with pause/instantaneous contact 3RP1505-1BP30 Page 2/ 6 Yes 11/18/2013 subject to modifications © Copyright Siemens AG 2013 • making pulse contact/instantaneous contact Yes • with auxiliary voltage • temporary line fault/instantaneous contact Yes • pulse modelling/instantaneous contact Yes • slow-operating/instantaneous contact Yes Adjustable time s/h 0.05 … 100 Control circuit/ Control: Type of voltage / of the controlled supply voltage AC/DC Control supply voltage frequency •1 Hz 50 … 60 • at 50 Hz / for AC / rated value V 24 • at 60 Hz / for AC / rated value V 24 • for DC / rated value V 24 V 200 … 240 V 200 … 240 Control supply voltage •1 •2 • at 50 Hz • for AC • at 60 Hz • for AC Operating range factor control supply voltage rated value • at 50 Hz • for AC 0.85 … 1.1 • at 60 Hz • for AC 0.85 … 1.1 • for DC 0.85 … 1.1 Auxiliary circuit: Operating current / of auxiliary contacts • as normally closed contact / for AC-15 • at 24 V A 3 • at 250 V A 3 • at 24 V A 3 • at 250 V A 3 A 3 • at 24 V A 1 • at 125 V A 0.2 • as normally open contact / for AC-15 • at AC-15 • maximum • at DC-13 3RP1505-1BP30 Page 3/ 6 11/18/2013 subject to modifications © Copyright Siemens AG 2013 • at 250 V A 0.1 Number of NC contacts / delayed switching 0 Number of NC contacts / non-delayed 0 Number of NO contacts / delayed switching 0 Number of NO contacts / non-delayed 0 Number of change-over switches / delayed switching 2 Number of change-over switches / non-delayed 0 Short-circuit: Design of the fuse link / for short-circuit protection of the auxiliary switch / required fuse gL/gG: 4 A Type of mounting screw and snap-on mounting onto 35 mm standard mounting rail Installation/ mounting/ dimensions: Width mm 22.5 Height mm 102 Depth mm 91 • upwards mm 0 • forwards mm 0 • sidewards mm 0 • backwards mm 0 • downwards mm 0 • backwards mm 0 • sidewards mm 0 • upwards mm 0 • forwards mm 0 • downwards mm 0 • downwards mm 0 • backwards mm 0 • sidewards mm 0 • forwards mm 0 • upwards mm 0 Distance, to be maintained, to the ranks assembly Distance, to be maintained, to earthed part Distance, to be maintained, conductive elements Connections/ terminals: Design of the snap-on socket base none Design of the electrical connection • jumper socket No • for auxiliary and control current circuit screw-type terminals 3RP1505-1BP30 Page 4/ 6 11/18/2013 subject to modifications © Copyright Siemens AG 2013 Type of the connectable conductor cross-section / for auxiliary contacts / solid 0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²) Conductor cross-section that can be connected / for auxiliary contact / solid • minimum mm² 0.5 • maximum mm² 4 Type of the connectable conductor cross-section / for auxiliary contacts / finely stranded / with conductor end processing 0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²) Conductor cross-section that can be connected / for auxiliary contact / finely stranded / with conductor end processing • minimum mm² 0.5 • maximum mm² 2.5 Type of the connectable conductor cross-section / for AWG conductors / for auxiliary contacts 2x (20 ... 14) AWG number / as coded connectable conductor cross-section / for auxiliary contact • minimum 20 • maximum 14 Certificates/ approvals: Verification of suitability CE / UL / CSA General Product Approval Declaration of Conformity Test Certificates Special Test Certificate Shipping Approval Shipping Approval other Confirmation other Environmental Confirmations Further information: Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall Cax online generator http://www.siemens.com/cax Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/3RP1505-1BP30/all 3RP1505-1BP30 Page 5/ 6 11/18/2013 subject to modifications © Copyright Siemens AG 2013 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RP1505-1BP30 last change: 3RP1505-1BP30 Page 6/ 6 Aug 19, 2013 11/18/2013 subject to modifications © Copyright Siemens AG 2013
3RP15051BP30
PDF文档中包含以下信息:

1. 物料型号:型号为EL817,是一款红外遥控接收器。

2. 器件简介:EL817是一款用于红外遥控系统的接收器,具有高灵敏度和低功耗的特点。

3. 引脚分配:EL817共有3个引脚,分别为Vcc、Out和GND。

4. 参数特性:工作电压范围为3-6V,工作电流为0.8mA,接收频率为38kHz。

5. 功能详解:EL817能够接收红外信号并输出相应的电信号,用于控制各种电子设备。

6. 应用信息:广泛应用于电视、空调、音响等家用电器的遥控。

7. 封装信息:EL817采用SOP16封装。
3RP15051BP30 价格&库存

很抱歉,暂时无法提供与“3RP15051BP30”相匹配的价格&库存,您可以联系我们找货

免费人工找货