0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RP15051BW30

3RP15051BW30

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3RP15051BW30 数据手册
Data sheet 3RP15 05-1BW30 TIME RELAY, MULTI-FUNCTION 2 CHANGEOVER, 16 FUNCTIONS, 15 TIME SETTING RANGES AC/DC 24... 240 V, WITH LED, SCREW CONNECTION General technical data: product brand name SIRIUS Product designation timing relay Mounting position any Product function non-volatile No Product component ● Relay output Yes ● semi-conductor output No Installation altitude at height above sea level maximum m 2 000 ● during operation °C -25 ... +60 ● during storage °C -40 ... +85 ● during transport °C -40 ... +85 % 10 ... 95 Ambient temperature Relative humidity during operation EMC emitted interference acc. to IEC 61812-1 EN 61000-6-4(3) EMI immunity acc. to IEC 61812-1 EN 61000-6-2 Conducted interference due to burst acc. to IEC 61000-4-4 2 kV network connection / 1 kV control connection 3RP15 05-1BW30 Page 1/6 16.12.2015 Changes preserved © Copyright Siemens AG Conducted interference due to conductor-earth surge acc. to IEC 61000-4-5 2 kV Conducted interference due to conductor-conductor surge acc. to IEC 61000-4-5 1 kV Electrostatic discharge acc. to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge Field-bound parasitic coupling acc. to IEC 61000-4-3 10 V/m Surge voltage resistance rated value V 4 000 Power loss [W] total typical W 2 Equipment marking acc. to DIN 40719 extended according to IEC 204-2 acc. to IEC 750 K Equipment marking acc. to DIN EN 81346-2 K Category acc. to EN 954-1 none Protection against electrical shock finger-safe Protection class IP IP20 Mechanical service life (switching cycles) typical 10 000 000 Electrical endurance (switching cycles) at AC-15 at 230 V typical 100 000 Operating frequency with 3RT2 contactor maximum 1/h Vibration resistance acc. to IEC 60068-2-6 5 000 10 ... 55 Hz / 0.35 mm Shock resistance acc. to IEC 60068-2-27 11g / 15 ms Relative repeat accuracy % 1 Recovery time ms 150 Minimum ON period ms 35 Degree of pollution 3 Insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value V 300 Relative setting accuracy relating to full-scale value % 5 Switching Function: Switching function ● ON-delay Yes ● ON-delay/instantaneous contact Yes ● passing make contact Yes ● passing make contact/instantaneous contact Yes ● OFF delay No ● flashing asymmetrically starting with interval No ● flashing asymmetrically starting with pulse No ● flashing symmetrically starting with pulse No ● flashing symmetrically starting with pulse/instantaneous No ● flashing symmetrically starting with interval Yes ● flashing symmetrically starting with interval/instantaneous Yes ● star-delta circuit Yes 3RP15 05-1BW30 Page 2/6 16.12.2015 Changes preserved © Copyright Siemens AG No ● star-delta circuit with delay time Switching function with control signal ● additive ON delay Yes ● passing break contact Yes ● OFF delay Yes ● pulse-shaping Yes ● OFF delay/instantaneous Yes ● ON-delay/OFF-delay/instantaneous Yes ● passing break contact/instantaneous Yes ● additive ON delay/instantaneous Yes ● ON-delay/OFF-delay Yes ● passing make contact No ● passing make contact/instantaneous contact No ● pulse delayed No ● pulse delayed/instantaneous No ● pulse-shaping/instantaneous Yes Switching function of interval relay with control signal ● retrotriggerable with deactivated control signal/instantaneous contact No ● retrotriggerable with activated control signal No ● retrotriggerable with activated control signal/instantaneous contact No ● retriggerable with deactivated control signal No Design of the control terminal non-floating Yes Control circuit/ Control: Adjustable time s Type of voltage of the control supply voltage Control supply voltage frequency 1 0.05 ... 360 000 AC/DC Hz 50 ... 60 — at 50 Hz V 24 ... 240 — at 60 Hz V 24 ... 240 V 24 ... 240 Control supply voltage 1 ● at AC ● at DC Operating range factor control supply voltage rated value ● at AC — at 50 Hz 0.8 ... 1.1 — at 60 Hz 0.8 ... 1.1 ● at DC 0.7 ... 1.1 Auxiliary circuit: Contact reliability of auxiliary contacts 3RP15 05-1BW30 Page 3/6 one incorrect switching operation of 100 million switching operations (17 V, 5 mA) 16.12.2015 Changes preserved © Copyright Siemens AG Material of switching contacts AgSnO2 Operating current of auxiliary contacts ● at AC-15 — at 24 V A 3 — at 250 V A 3 — at 24 V A 1 — at 125 V A 0.2 — at 250 V A 0.1 ● at DC-13 Design of the fuse link for short-circuit protection of the auxiliary switch required Thermal current fuse gL/gG: 4 A A 5 Number of NC contacts ● delayed switching 0 ● instantaneous contact 0 Number of NO contacts ● delayed switching 0 ● instantaneous contact 0 Number of CO contacts ● delayed switching 2 ● instantaneous contact 0 Installation/ mounting/ dimensions: Mounting type screw and snap-on mounting onto 35 mm standard mounting rail Width mm 22.5 Height mm 102 Depth mm 91 ● upwards mm 0 ● forwards mm 0 ● at the side mm 0 ● Backwards mm 0 ● downwards mm 0 ● Backwards mm 0 ● at the side mm 0 ● upwards mm 0 ● forwards mm 0 ● downwards mm 0 ● downwards mm 0 ● Backwards mm 0 Required spacing with side-by-side mounting Required spacing for grounded parts Required spacing for live parts 3RP15 05-1BW30 Page 4/6 16.12.2015 Changes preserved © Copyright Siemens AG ● at the side mm 0 ● forwards mm 0 ● upwards mm 0 Connections/ Terminals: Type of electrical connection for auxiliary and control current circuit screw-type terminals Type of connectable conductor cross-sections 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) ● solid ● finely stranded 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) — with core end processing ● at AWG conductors — stranded 2x (20 ... 14) — solid 2x (20 ... 14) Tightening torque N·m 0.8 ... 1.2 Certificates/ approvals: General Product Approval Declaration of Conformity Test Certificates spezielle Prüfbescheinigunge n Shipping Approval Shipping Approval other Bestätigungen sonstig Umweltbestätigung Further information Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrymall Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP15051BW30 3RP15 05-1BW30 Page 5/6 16.12.2015 Changes preserved © Copyright Siemens AG Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RP15051BW30 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP15051BW30&lang=en 86 65 5 23 36 last modified: 3RP15 05-1BW30 Page 6/6 92 102 83 74 120 7 110x15 87 68 4 08.12.2015 16.12.2015 Changes preserved © Copyright Siemens AG
3RP15051BW30 价格&库存

很抱歉,暂时无法提供与“3RP15051BW30”相匹配的价格&库存,您可以联系我们找货

免费人工找货