Data sheet
3RP15 05-1BW30
TIME RELAY, MULTI-FUNCTION 2 CHANGEOVER, 16
FUNCTIONS, 15 TIME SETTING RANGES AC/DC 24...
240 V, WITH LED, SCREW CONNECTION
General technical data:
product brand name
SIRIUS
Product designation
timing relay
Mounting position
any
Product function non-volatile
No
Product component
● Relay output
Yes
● semi-conductor output
No
Installation altitude at height above sea level
maximum
m
2 000
● during operation
°C
-25 ... +60
● during storage
°C
-40 ... +85
● during transport
°C
-40 ... +85
%
10 ... 95
Ambient temperature
Relative humidity during operation
EMC emitted interference acc. to IEC 61812-1
EN 61000-6-4(3)
EMI immunity acc. to IEC 61812-1
EN 61000-6-2
Conducted interference due to burst acc. to IEC
61000-4-4
2 kV network connection / 1 kV control connection
3RP15 05-1BW30
Page 1/6
16.12.2015
Changes preserved
© Copyright Siemens AG
Conducted interference due to conductor-earth surge
acc. to IEC 61000-4-5
2 kV
Conducted interference due to conductor-conductor
surge acc. to IEC 61000-4-5
1 kV
Electrostatic discharge acc. to IEC 61000-4-2
4 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling acc. to IEC 61000-4-3
10 V/m
Surge voltage resistance rated value
V
4 000
Power loss [W] total typical
W
2
Equipment marking acc. to DIN 40719 extended
according to IEC 204-2 acc. to IEC 750
K
Equipment marking acc. to DIN EN 81346-2
K
Category acc. to EN 954-1
none
Protection against electrical shock
finger-safe
Protection class IP
IP20
Mechanical service life (switching cycles) typical
10 000 000
Electrical endurance (switching cycles) at AC-15 at
230 V typical
100 000
Operating frequency with 3RT2 contactor maximum
1/h
Vibration resistance acc. to IEC 60068-2-6
5 000
10 ... 55 Hz / 0.35 mm
Shock resistance acc. to IEC 60068-2-27
11g / 15 ms
Relative repeat accuracy
%
1
Recovery time
ms
150
Minimum ON period
ms
35
Degree of pollution
3
Insulation voltage for overvoltage category III
according to IEC 60664 with degree of pollution 3
rated value
V
300
Relative setting accuracy relating to full-scale value
%
5
Switching Function:
Switching function
● ON-delay
Yes
● ON-delay/instantaneous contact
Yes
● passing make contact
Yes
● passing make contact/instantaneous contact
Yes
● OFF delay
No
● flashing asymmetrically starting with interval
No
● flashing asymmetrically starting with pulse
No
● flashing symmetrically starting with pulse
No
● flashing symmetrically starting with
pulse/instantaneous
No
● flashing symmetrically starting with interval
Yes
● flashing symmetrically starting with
interval/instantaneous
Yes
● star-delta circuit
Yes
3RP15 05-1BW30
Page 2/6
16.12.2015
Changes preserved
© Copyright Siemens AG
No
● star-delta circuit with delay time
Switching function with control signal
● additive ON delay
Yes
● passing break contact
Yes
● OFF delay
Yes
● pulse-shaping
Yes
● OFF delay/instantaneous
Yes
● ON-delay/OFF-delay/instantaneous
Yes
● passing break contact/instantaneous
Yes
● additive ON delay/instantaneous
Yes
● ON-delay/OFF-delay
Yes
● passing make contact
No
● passing make contact/instantaneous contact
No
● pulse delayed
No
● pulse delayed/instantaneous
No
● pulse-shaping/instantaneous
Yes
Switching function of interval relay with control signal
● retrotriggerable with deactivated control
signal/instantaneous contact
No
● retrotriggerable with activated control signal
No
● retrotriggerable with activated control
signal/instantaneous contact
No
● retriggerable with deactivated control signal
No
Design of the control terminal non-floating
Yes
Control circuit/ Control:
Adjustable time
s
Type of voltage of the control supply voltage
Control supply voltage frequency 1
0.05 ... 360 000
AC/DC
Hz
50 ... 60
— at 50 Hz
V
24 ... 240
— at 60 Hz
V
24 ... 240
V
24 ... 240
Control supply voltage 1
● at AC
● at DC
Operating range factor control supply voltage rated
value
● at AC
— at 50 Hz
0.8 ... 1.1
— at 60 Hz
0.8 ... 1.1
● at DC
0.7 ... 1.1
Auxiliary circuit:
Contact reliability of auxiliary contacts
3RP15 05-1BW30
Page 3/6
one incorrect switching operation of 100 million
switching operations (17 V, 5 mA)
16.12.2015
Changes preserved
© Copyright Siemens AG
Material of switching contacts
AgSnO2
Operating current of auxiliary contacts
● at AC-15
— at 24 V
A
3
— at 250 V
A
3
— at 24 V
A
1
— at 125 V
A
0.2
— at 250 V
A
0.1
● at DC-13
Design of the fuse link for short-circuit protection of
the auxiliary switch required
Thermal current
fuse gL/gG: 4 A
A
5
Number of NC contacts
● delayed switching
0
● instantaneous contact
0
Number of NO contacts
● delayed switching
0
● instantaneous contact
0
Number of CO contacts
● delayed switching
2
● instantaneous contact
0
Installation/ mounting/ dimensions:
Mounting type
screw and snap-on mounting onto 35 mm standard
mounting rail
Width
mm
22.5
Height
mm
102
Depth
mm
91
● upwards
mm
0
● forwards
mm
0
● at the side
mm
0
● Backwards
mm
0
● downwards
mm
0
● Backwards
mm
0
● at the side
mm
0
● upwards
mm
0
● forwards
mm
0
● downwards
mm
0
● downwards
mm
0
● Backwards
mm
0
Required spacing with side-by-side mounting
Required spacing for grounded parts
Required spacing for live parts
3RP15 05-1BW30
Page 4/6
16.12.2015
Changes preserved
© Copyright Siemens AG
● at the side
mm
0
● forwards
mm
0
● upwards
mm
0
Connections/ Terminals:
Type of electrical connection for auxiliary and control
current circuit
screw-type terminals
Type of connectable conductor cross-sections
1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
● solid
● finely stranded
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
— with core end processing
● at AWG conductors
— stranded
2x (20 ... 14)
— solid
2x (20 ... 14)
Tightening torque
N·m
0.8 ... 1.2
Certificates/ approvals:
General Product Approval
Declaration of
Conformity
Test
Certificates
spezielle
Prüfbescheinigunge
n
Shipping Approval
Shipping
Approval
other
Bestätigungen
sonstig
Umweltbestätigung
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
http://www.siemens.com/industrymall
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP15051BW30
3RP15 05-1BW30
Page 5/6
16.12.2015
Changes preserved
© Copyright Siemens AG
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RP15051BW30
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP15051BW30&lang=en
86
65
5
23
36
last modified:
3RP15 05-1BW30
Page 6/6
92
102
83
74
120
7
110x15
87
68
4
08.12.2015
16.12.2015
Changes preserved
© Copyright Siemens AG
很抱歉,暂时无法提供与“3RP15051BW30”相匹配的价格&库存,您可以联系我们找货
免费人工找货