3RP2005-1AP30

3RP2005-1AP30

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    RELAY TIME DELAY

  • 数据手册
  • 价格&库存
3RP2005-1AP30 数据手册
Data sheet 3RP2005-1AP30 Timing relay, electronic Multifunction, 8 functions 1 change-over contact 24 V AC/DC, 200 to 240 V AC at 50/60 Hz AC 0.05 s to 100 h Overall width 45 mm screw terminal product brand name SIRIUS product designation timing relay design of the product Multifunctional product type designation 3RP20 General technical data product component ● relay output Yes ● semi-conductor output No product extension required remote control No product extension optional remote control No insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value 300 V test voltage for isolation test 2 kV degree of pollution 3 surge voltage resistance rated value 4 000 V shock resistance acc. to IEC 60068-2-27 11g / 15 ms vibration resistance acc. to IEC 60068-2-6 10 ... 55 Hz / 0.35 mm mechanical service life (switching cycles) typical 10 000 000 electrical endurance (switching cycles) at AC-15 at 230 V typical 100 000 adjustable time 0.05 s ... 100 h relative setting accuracy relating to full-scale value 5% thermal current 5A minimum ON period 35 ms recovery time 150 ms reference code acc. to IEC 81346-2 K relative repeat accuracy 1% Control circuit/ Control type of voltage of the control supply voltage AC/DC control supply voltage 1 at AC ● at 50 Hz rated value 24 V ● at 60 Hz rated value 24 V control supply voltage 2 at AC ● at 50 Hz 200 ... 240 V ● at 60 Hz 200 ... 240 V control supply voltage frequency 1 ● control supply voltage 1 at DC rated value 50 ... 60 Hz 24 V operating range factor control supply voltage rated 3RP20051AP30 Page 1/2 12.20.2020 Subject to change without notice © Copyright Siemens value at DC ● initial value 0.85 ● full-scale value 1.1 operating range factor control supply voltage rated value at AC at 50 Hz ● initial value 0.85 ● full-scale value 1.1 operating range factor control supply voltage rated value at AC at 60 Hz ● initial value 0.85 ● full-scale value 1.1 Switching Function switching function ● ON-delay Yes ● ON-delay/instantaneous contact No ● passing make contact Yes ● passing make contact/instantaneous contact No ● OFF delay No switching function ● flashing symmetrically with interval start/instantaneous No ● flashing symmetrically with interval start Yes ● flashing symmetrically with pulse start/instantaneous No ● flashing symmetrically with pulse start No ● flashing asymmetrically with interval start No ● flashing asymmetrically with pulse start No switching function ● star-delta circuit with delay time No ● star-delta circuit No switching function with control signal ● additive ON-delay Yes ● passing break contact Yes ● passing break contact/instantaneous No ● OFF delay Yes ● OFF delay/instantaneous No ● pulse delayed No ● pulse delayed/instantaneous No ● pulse-shaping Yes ● pulse-shaping/instantaneous No ● additive ON-delay/instantaneous No ● ON-delay/OFF-delay/instantaneous No ● passing make contact No ● passing make contact/instantaneous contact No switching function of interval relay with control signal ● retrotriggerable with deactivated control signal/instantaneous contact No ● retrotriggerable with switched-on control signal No ● retrotriggerable with switched-on control signal/instantaneous contact No ● retriggerable with deactivated control signal No design of the control terminal non-floating Yes Short-circuit protection design of the fuse link for short-circuit protection of the auxiliary switch required fuse gL/gG: 4 A Auxiliary circuit material of switching contacts AgSnO2 number of NC contacts delayed switching 0 number of NO contacts delayed switching 0 number of CO contacts delayed switching 1 3RP20051AP30 Page 2/3 12.20.2020 Subject to change without notice © Copyright Siemens operational current of auxiliary contacts at AC-15 ● at 24 V 3A ● at 250 V 3A operational current of auxiliary contacts at DC-13 ● at 24 V 1A ● at 125 V 0.2 A ● at 250 V 0.1 A operating frequency with 3RT2 contactor maximum 5 000 1/h contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching operations (17 V, 5 mA) contact rating of auxiliary contacts according to UL R300 / B300 influence of the surrounding temperature ±5 % power supply influence ±1 % Inputs/ Outputs product function ● non-volatile No Electromagnetic compatibility EMC immunity acc. to IEC 61812-1 EN 61000-6-2 conducted interference ● due to burst acc. to IEC 61000-4-4 2 kV network connection / 1 kV control connection ● due to conductor-earth surge acc. to IEC 61000-4-5 2 kV ● due to conductor-conductor surge acc. to IEC 61000-4-5 1 kV field-based interference acc. to IEC 61000-4-3 10 V/m electrostatic discharge acc. to IEC 61000-4-2 4 kV contact discharge / 8 kV air discharge Safety related data touch protection against electrical shock finger-safe type of insulation Basic insulation category acc. to EN 954-1 none Connections/ Terminals product function removable terminal for auxiliary and control circuit No type of electrical connection for auxiliary and control circuit screw-type terminals type of connectable conductor cross-sections ● solid 2x (0,5 ...1,5 mm²), 2x (0,75 ... 2,5 mm²) ● finely stranded with core end processing 2x (0,5 ...1,5 mm²), 2x (0,75 ... 2,5 mm²) ● at AWG cables solid 2x (18 ... 14) ● at AWG cables stranded 2x (18 ... 14) ● connectable conductor cross-section solid 0.5 ... 2.5 mm² ● connectable conductor cross-section finely stranded with core end processing 0.5 ... 2.5 mm² ● AWG number as coded connectable conductor cross section solid 18 ... 14 ● AWG number as coded connectable conductor cross section stranded 18 ... 14 tightening torque 0.8 ... 1.2 N·m design of the thread of the connection screw M3 Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting onto 35 mm standard mounting rail height 57 mm width 45 mm depth 73 mm required spacing ● with side-by-side mounting — forwards 0 mm — backwards 0 mm — upwards 0 mm — downwards 0 mm 3RP20051AP30 Page 3/4 12.20.2020 Subject to change without notice © Copyright Siemens — at the side 0 mm ● for grounded parts — forwards 0 mm — backwards 0 mm — upwards 0 mm — at the side 0 mm — downwards 0 mm ● for live parts — forwards 0 mm — backwards 0 mm — upwards 0 mm — downwards 0 mm — at the side 0 mm Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -25 ... +60 °C ● ambient temperature during storage -40 ... +85 °C ● ambient temperature during transport -40 ... +85 °C relative humidity during operation 10 ... 95 % Certificates/ approvals General Product Approval EMC Declaration of Conformity Miscellaneous Test Certificates Marine / Shipping Type Test Certificates/Test Report Marine / Shipping other Confirmation Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RP2005-1AP30 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RP2005-1AP30 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RP2005-1AP30 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RP2005-1AP30&lang=en Characteristic: Derating https://support.industry.siemens.com/cs/ww/en/ps/3RP2005-1AP30/manual 3RP20051AP30 Page 4/5 12.20.2020 Subject to change without notice © Copyright Siemens last modified: 3RP20051AP30 Page 5/5 11/20/2020 12.20.2020 Subject to change without notice © Copyright Siemens
3RP2005-1AP30 价格&库存

很抱歉,暂时无法提供与“3RP2005-1AP30”相匹配的价格&库存,您可以联系我们找货

免费人工找货