3RQ20002AW00

3RQ20002AW00

  • 厂商:

    SIEMENS(西门子)

  • 封装:

  • 描述:

    COUPLING RELAY IM

  • 数据手册
  • 价格&库存
3RQ20002AW00 数据手册
Data sheet 3RQ2000-2AW00 Coupling relay in industrial enclosure 1 changeover contact Wide voltage range 24 V to 240 V AC/DC Spring-type terminals product brand name SIRIUS product designation Coupling relay in industrial enclosure product type designation 3RQ2 General technical data consumed active power 4W insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value 300 V degree of pollution 3 surge voltage resistance rated value 4 kV maximum permissible voltage for safe isolation ● between auxiliary and auxiliary circuit 300 V ● between control and auxiliary circuit acc. to IEC 60947-1 300 V protection class IP IP20 shock resistance ● acc. to IEC 60068-2-27 11g / 15 ms ● for railway applications acc. to DIN EN 61373 Category 1, Class B vibration resistance ● acc. to IEC 60068-2-6 10 ... 55 Hz: 0.35 mm ● for railway applications acc. to DIN EN 61373 Category 1, Class B switching behavior monostable mechanical service life (switching cycles) typical 10 000 000 electrical endurance (switching cycles) at AC-15 at 230 V typical 100 000 thermal current of the switching element with contacts maximum 5A reference code acc. to IEC 81346-2 K Control circuit/ Control control supply voltage 1 at AC ● at 50 Hz 24 ... 240 V ● at 60 Hz 24 ... 240 V ● control supply voltage 1 at DC 24 ... 240 V operating range factor control supply voltage rated value at DC ● initial value 0.7 ● full-scale value 1.1 operating range factor control supply voltage rated value at AC at 50 Hz ● initial value 3RQ20002AW00 Page 1/2 0.7 12.20.2020 Subject to change without notice © Copyright Siemens ● full-scale value 1.1 operating range factor control supply voltage rated value at AC at 60 Hz ● initial value 0.7 ● full-scale value 1.1 switch ON delay time ● at AC maximum 10 ms ● at DC maximum 10 ms OFF delay time 100 ms design of the relay operating mechanism poled product component plug-in socket No Short-circuit protection design of the fuse link for short-circuit protection of the auxiliary switch required fuse gL/gG: 6 A Auxiliary circuit material of switching contacts AgSnO2 number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 0 number of CO contacts for auxiliary contacts 1 contact reliability of auxiliary contacts one incorrect switching operation of 100 million switching operations (17 V, 5 mA) type of voltage AC/DC Outputs ampacity of the output relay at AC-15 ● at 24 V at 50/60 Hz 3A ● at 110 V at 50/60 Hz 3A ● at 250 V at 50/60 Hz 3A ampacity of the output relay at DC-13 ● at 24 V 1A ● at 125 V 0.2 A ● at 250 V 0.1 A Electromagnetic compatibility EMC emitted interference acc. to IEC 60947-1 ambience A (industrial sector) EMC immunity acc. to IEC 60947-1 corresponds to degree of severity 3 conducted interference ● due to burst acc. to IEC 61000-4-4 2 kV ● due to conductor-earth surge acc. to IEC 61000-4-5 2 kV (line to ground) ● due to conductor-conductor surge acc. to IEC 61000-4-5 1 kV (line to line) field-based interference acc. to IEC 61000-4-3 10 V/m electrostatic discharge acc. to IEC 61000-4-2 4 kV contact discharging, 8 kV air discharging Safety related data electromagnetic compatibility IEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4 Connections/ Terminals product function removable terminal for auxiliary and control circuit Yes type of electrical connection Push-in terminal type of connectable conductor cross-sections ● solid 0.5 ... 4 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² ● at AWG cables solid 20 ... 12 ● connectable conductor cross-section solid 0.5 ... 4 mm² ● connectable conductor cross-section finely stranded with core end processing 2.5 mm² ● connectable conductor cross-section finely stranded without core end processing 0.5 mm² ● AWG number as coded connectable conductor cross section solid 12 ... 20 ● AWG number as coded connectable conductor 12 ... 20 3RQ20002AW00 Page 2/3 12.20.2020 Subject to change without notice © Copyright Siemens cross section stranded stripped length of the cable for auxiliary and control contacts 10 mm Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting onto 35 mm standard mounting rail height 100 mm width 22.5 mm depth 90 mm Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -40 ... +60 °C ● ambient temperature during storage -40 ... +80 °C ● ambient temperature during transport -40 ... +80 °C relative humidity during operation 10 ... 95 % Certificates/ approvals General Product Approval Declaration of Conformity Miscellaneous EMC Test Certificates Marine / Shipping Type Test Certificates/Test Report other Confirmation Railway Confirmation Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RQ2000-2AW00 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RQ2000-2AW00 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RQ2000-2AW00 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RQ2000-2AW00&lang=en Characteristic: Derating https://support.industry.siemens.com/cs/ww/en/ps/3RQ2000-2AW00/manual 3RQ20002AW00 Page 3/4 12.20.2020 Subject to change without notice © Copyright Siemens 3RQ20002AW00 Page 4/5 12.20.2020 Subject to change without notice © Copyright Siemens last modified: 11/5/2020 3RQ20002AW00 Page 5/5 12.20.2020 Subject to change without notice © Copyright Siemens
3RQ20002AW00 价格&库存

很抱歉,暂时无法提供与“3RQ20002AW00”相匹配的价格&库存,您可以联系我们找货

免费人工找货
3RQ20002AW00
  •  国内价格 香港价格
  • 1+864.546781+108.41583

库存:0