0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RT10752XJ460LA2

3RT10752XJ460LA2

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR AC3:200 KW/400V 2NO+2N

  • 数据手册
  • 价格&库存
3RT10752XJ460LA2 数据手册
Data sheet 3RT1075-2XJ46-0LA2 Traction contactor, AC-3 400 A, 200 kW / 400 V Coil 72 V DC x (0.7-1.25) PLC input 24-110 V DC Auxiliary contacts 2 NO + 2 NC 3-pole size S12 Busbar connections Coil connection: Spring-type terminal product brand name SIRIUS product designation Contactor design of the product With extended operating range product type designation 3RT1 General technical data size of contactor S12 product extension ● function module for communication No ● auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 105 W ● at AC in hot operating state per pole 35 W ● without load current share typical 3.6 W insulation voltage ● of main circuit with degree of pollution 3 rated value 1 000 V ● of auxiliary circuit with degree of pollution 3 rated value 500 V surge voltage resistance ● of main circuit rated value 8 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1 690 V shock resistance for railway applications according to EN 61373 Category 1, Class B shock resistance at rectangular impulse ● at DC 8,5g / 5 ms, 4,2g / 10 ms shock resistance with sine pulse ● at DC 13,4g / 5 ms, 6,5g / 10 ms mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 09/06/2016 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -40 ... +70 °C ● during storage -55 ... +80 °C 3RT10752XJ460LA2 Page 1/6 7/8/2022 Subject to change without notice © Copyright Siemens relative humidity minimum 10 % relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 % Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 number of NC contacts for main contacts 0 operating voltage ● at AC-3 rated value maximum 1 000 V ● at AC-3e rated value maximum 1 000 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 430 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 430 A — up to 690 V at ambient temperature 60 °C rated value 400 A — up to 1000 V at ambient temperature 60 °C rated value 200 A ● at AC-2 at 400 V rated value 400 A ● at AC-3 — at 400 V rated value 400 A — at 500 V rated value 400 A — at 690 V rated value 400 A — at 1000 V rated value 180 A ● at AC-3e — at 400 V rated value 400 A — at 500 V rated value 400 A — at 690 V rated value 400 A — at 1000 V rated value 180 A ● at AC-4 at 400 V rated value 350 A minimum cross-section in main circuit ● at maximum AC-1 rated value 300 mm² ● at maximum Ith rated value 300 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 150 A ● at 690 V rated value 135 A operating power ● at AC-2 at 400 V rated value 200 kW ● at AC-3 — at 230 V rated value 132 kW — at 400 V rated value 200 kW — at 500 V rated value 250 kW — at 690 V rated value 400 kW — at 1000 V rated value 250 kW ● at AC-3e — at 230 V rated value 132 kW — at 400 V rated value 200 kW — at 500 V rated value 250 kW — at 690 V rated value 400 kW — at 1000 V rated value 250 kW operating power for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 85 kW ● at 690 V rated value 133 kW short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 6 600 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 5 761 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 4 143 A; Use minimum cross-section acc. to AC-1 rated value 3RT10752XJ460LA2 Page 2/6 7/8/2022 Subject to change without notice © Copyright Siemens ● limited to 30 s switching at zero current maximum 2 635 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 2 088 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at DC 500 1/h operating frequency ● at AC-1 maximum 500 1/h ● at AC-2 maximum 200 1/h ● at AC-3 maximum 500 1/h ● at AC-3e maximum 500 1/h ● at AC-2 at AC-3e maximum 200 1/h ● at AC-4 maximum 130 1/h operating frequency ● at DC-1 maximum 250 1/h ● at DC-3 maximum 250 1/h ● at DC-5 maximum 250 1/h Ratings for railway applications thermal current (Ith) up to 690 V ● up to 40 °C according to IEC 60077 rated value 430 A ● up to 70 °C according to IEC 60077 rated value 350 A Control circuit/ Control type of voltage DC type of voltage of the control supply voltage DC control supply voltage at DC ● rated value 72 V consumed current at PLC-control input according to IEC 60947-1 maximum 2 mA voltage at PLC-control input rated value 24 V operating range factor control supply voltage rated value of magnet coil at DC ● initial value 0.7 ● full-scale value 1.25 design of the surge suppressor with varistor closing power of magnet coil at DC 800 W holding power of magnet coil at DC 3.6 W closing delay ● at DC 60 ... 90 ms opening delay ● at DC 80 ... 100 ms arcing time 10 ... 15 ms control version of the switch operating mechanism PLC-IN or Standard A1 - A2 (adjustable) Auxiliary circuit number of NC contacts for auxiliary contacts ● instantaneous contact number of NO contacts for auxiliary contacts ● instantaneous contact operational current at AC-12 maximum 2 2 2 2 10 A operational current at AC-15 ● at 230 V rated value 6A ● at 400 V rated value 3A ● at 500 V rated value 2A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 3RT10752XJ460LA2 Page 3/6 6A 7/8/2022 Subject to change without notice © Copyright Siemens ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 361 A ● at 600 V rated value 382 A yielded mechanical performance [hp] ● for 3-phase AC motor — at 200/208 V rated value 125 hp — at 220/230 V rated value 150 hp — at 460/480 V rated value 300 hp — at 575/600 V rated value 400 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection product function short circuit protection No design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 630 A (690 V, 100 kA) — with type of assignment 2 required gG: 500 A (690 V, 100 kA), aM: 400 A (690 V, 50 kA), BS88: 450 A (415 V, 50 kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back fastening method screw fixing ● side-by-side mounting Yes height 214 mm width 160 mm depth 225 mm required spacing ● with side-by-side mounting — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 10 mm ● for grounded parts — forwards 20 mm — upwards 10 mm — at the side 10 mm — downwards 10 mm ● for live parts — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 10 mm Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit spring-loaded terminals width of connection bar 25 mm thickness of connection bar 6 mm diameter of holes 11 mm number of holes 1 type of connectable conductor cross-sections ● for main contacts 3RT10752XJ460LA2 Page 4/6 7/8/2022 Subject to change without notice © Copyright Siemens — solid or stranded 2x (70 ... 240 mm²) ● at AWG cables for main contacts 2/0 ... 500 kcmil type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.25 ... 2.5 mm²) — solid or stranded 2x (0,25 ... 2,5 mm²) — finely stranded with core end processing 2x (0.25 ... 1.5 mm²) — finely stranded without core end processing 2x (0.25 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (24 ... 14) AWG number as coded connectable conductor cross section ● for auxiliary contacts 24 ... 14 Safety related data product function ● mirror contact according to IEC 60947-4-1 Yes ● positively driven operation according to IEC 609475-1 No B10 value with high demand rate according to SN 31920 1 000 000 protection class IP on the front according to IEC 60529 IP00; IP20 with box terminal/cover touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front with box terminal/cover Communication/ Protocol product function bus communication No Certificates/ approvals General Product Approval EMC Confirmation Functional Safety/Safety of Machinery Declaration of Conformity Test Certificates Type Examination Certificate Special Test Certificate other Confirmation other Type Test Certificates/Test Report Miscellaneous Railway Miscellaneous Special Test Certificate Type Test Certificates/Test Report Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT1075-2XJ46-0LA2 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT1075-2XJ46-0LA2 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT1075-2XJ46-0LA2 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT1075-2XJ46-0LA2&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT1075-2XJ46-0LA2/char 3RT10752XJ460LA2 Page 5/6 7/8/2022 Subject to change without notice © Copyright Siemens Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT1075-2XJ46-0LA2&objecttype=14&gridview=view1 last modified: 3RT10752XJ460LA2 Page 6/6 3/26/2022 7/8/2022 Subject to change without notice © Copyright Siemens
3RT10752XJ460LA2 价格&库存

很抱歉,暂时无法提供与“3RT10752XJ460LA2”相匹配的价格&库存,您可以联系我们找货

免费人工找货