3RT20161JB41

3RT20161JB41

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    COUPLNG RELAY S00 9A 24VDC 1NO S

  • 数据手册
  • 价格&库存
3RT20161JB41 数据手册
Data sheet 3RT2016-1JB41 power contactor, AC-3 9 A, 4 kW / 400 V 1 NO, 24 V DC 0.7-1.25* US, with diode integrated, 3-pole, size S00, screw terminal suitable for PLC outputs not expandable with auxiliary switch product brand name SIRIUS product designation Coupling contactor product type designation 3RT2 General technical data size of contactor S00 product extension ● function module for communication No ● auxiliary switch No power loss [W] for rated value of the current ● at AC in hot operating state 0.9 W ● at AC in hot operating state per pole 0.3 W ● without load current share typical 2.8 W insulation voltage ● of main circuit with degree of pollution 3 rated value 690 V ● of auxiliary circuit with degree of pollution 3 rated value 690 V surge voltage resistance ● of main circuit rated value 6 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1 400 V shock resistance at rectangular impulse ● at DC 6,7g / 5 ms, 4,2g / 10 ms shock resistance with sine pulse ● at DC 10,5g / 5 ms, 6,6g / 10 ms mechanical service life (switching cycles) ● of contactor typical 30 000 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 10/01/2009 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -25 ... +60 °C ● during storage -55 ... +80 °C relative humidity minimum 10 % relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 % Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 3RT20161JB41 Page 1/7 7/4/2022 Subject to change without notice © Copyright Siemens operating voltage ● at AC-3 rated value maximum 690 V ● at AC-3e rated value maximum 690 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 22 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 22 A — up to 690 V at ambient temperature 60 °C rated value 20 A ● at AC-3 — at 400 V rated value 9A — at 500 V rated value 7.7 A — at 690 V rated value 6.7 A ● at AC-3e — at 400 V rated value 9A — at 500 V rated value 7.7 A — at 690 V rated value 6.7 A ● at AC-4 at 400 V rated value 8.5 A ● at AC-5a up to 690 V rated value 19.4 A ● at AC-5b up to 400 V rated value 7.4 A ● at AC-6a — up to 230 V for current peak value n=20 rated value 5.3 A — up to 400 V for current peak value n=20 rated value 5.3 A — up to 500 V for current peak value n=20 rated value 5.3 A — up to 690 V for current peak value n=20 rated value 5A ● at AC-6a — up to 230 V for current peak value n=30 rated value 3.5 A — up to 400 V for current peak value n=30 rated value 3.5 A — up to 500 V for current peak value n=30 rated value 3.6 A — up to 690 V for current peak value n=30 rated value 3.3 A minimum cross-section in main circuit at maximum AC-1 rated value 4 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 4.1 A ● at 690 V rated value 3.3 A operational current ● at 1 current path at DC-1 — at 24 V rated value 20 A — at 110 V rated value 2.1 A — at 220 V rated value 0.8 A — at 440 V rated value 0.6 A — at 600 V rated value 0.6 A ● with 2 current paths in series at DC-1 — at 24 V rated value 20 A — at 110 V rated value 12 A — at 220 V rated value 1.6 A — at 440 V rated value 0.8 A — at 600 V rated value 0.7 A ● with 3 current paths in series at DC-1 — at 24 V rated value 20 A — at 110 V rated value 20 A — at 220 V rated value 20 A 3RT20161JB41 Page 2/7 7/4/2022 Subject to change without notice © Copyright Siemens — at 440 V rated value 1.3 A — at 600 V rated value 1A ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 20 A — at 110 V rated value 0.1 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 20 A — at 110 V rated value 0.35 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 20 A — at 110 V rated value 20 A — at 220 V rated value 1.5 A — at 440 V rated value 0.2 A — at 600 V rated value 0.2 A operating power ● at AC-3 — at 230 V rated value 2.2 kW — at 400 V rated value 4 kW — at 500 V rated value 4 kW — at 690 V rated value 5.5 kW ● at AC-3e — at 230 V rated value 2.2 kW — at 400 V rated value 4 kW — at 500 V rated value 4 kW — at 690 V rated value 5 kW operating power for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 2 kW ● at 690 V rated value 2.5 kW operating apparent power at AC-6a ● up to 230 V for current peak value n=20 rated value 2 kVA ● up to 400 V for current peak value n=20 rated value 3.6 kVA ● up to 500 V for current peak value n=20 rated value 4.6 kVA ● up to 690 V for current peak value n=20 rated value 5.9 kVA operating apparent power at AC-6a ● up to 230 V for current peak value n=30 rated value 1.3 kVA ● up to 400 V for current peak value n=30 rated value 2.4 kVA ● up to 500 V for current peak value n=30 rated value 3.1 kVA ● up to 690 V for current peak value n=30 rated value 4 kVA short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 155 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 111 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 86 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum 66 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 55 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at DC 10 000 1/h operating frequency ● at AC-1 maximum 1 000 1/h ● at AC-2 maximum 750 1/h ● at AC-3 maximum 750 1/h ● at AC-3e maximum 750 1/h ● at AC-4 maximum 250 1/h Control circuit/ Control type of voltage of the control supply voltage DC control supply voltage at DC ● rated value 24 V operating range factor control supply voltage rated value of magnet coil at DC ● initial value 3RT20161JB41 Page 3/7 0.7 7/4/2022 Subject to change without notice © Copyright Siemens ● full-scale value 1.25 design of the surge suppressor diode closing power of magnet coil at DC 2.8 W holding power of magnet coil at DC 2.8 W closing delay ● at DC 25 ... 130 ms opening delay ● at DC 38 ... 65 ms arcing time 10 ... 15 ms control version of the switch operating mechanism Standard A1 - A2 Auxiliary circuit number of NO contacts for auxiliary contacts instantaneous contact 1 operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 10 A ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 7.6 A ● at 600 V rated value 9A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 0.33 hp — at 230 V rated value 1 hp ● for 3-phase AC motor — at 200/208 V rated value 2 hp — at 220/230 V rated value 3 hp — at 460/480 V rated value 5 hp — at 575/600 V rated value 7.5 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA) — with type of assignment 2 required gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position 3RT20161JB41 Page 4/7 +/-180° rotation possible on vertical mounting surface; can be tilted 7/4/2022 Subject to change without notice © Copyright Siemens forward and backward by +/- 22.5° on vertical mounting surface fastening method ● side-by-side mounting screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 Yes height 58 mm width 45 mm depth 73 mm required spacing ● with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm ● for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit screw-type terminals ● at contactor for auxiliary contacts Screw-type terminals ● of magnet coil Screw-type terminals type of connectable conductor cross-sections ● for main contacts — solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² — solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm² — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG cables for main contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12 connectable conductor cross-section for main contacts ● solid 0.5 ... 4 mm² ● stranded 0.5 ... 4 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² connectable conductor cross-section for auxiliary contacts ● solid or stranded 0.5 ... 4 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12 AWG number as coded connectable conductor cross section ● for main contacts 20 ... 12 ● for auxiliary contacts 20 ... 12 Safety related data product function ● mirror contact according to IEC 60947-4-1 B10 value with high demand rate according to SN 31920 No 1 000 000 proportion of dangerous failures ● with low demand rate according to SN 31920 40 % ● with high demand rate according to SN 31920 73 % failure rate [FIT] with low demand rate according to SN 3RT20161JB41 Page 5/7 100 FIT 7/4/2022 Subject to change without notice © Copyright Siemens 31920 T1 value for proof test interval or service life according to IEC 61508 20 y protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front suitability for use ● safety-related switching OFF Yes Certificates/ approvals General Product Approval Confirmation EMC Functional Safety/Safety of Machinery KC Declaration of Conformity Type Examination Certificate Test Certificates Type Test Certificates/Test Report Special Test Certificate Marine / Shipping Marine / Shipping other Confirmation Railway Special Test Certificate Dangerous Good Transport Information Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2016-1JB41 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2016-1JB41 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT2016-1JB41 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2016-1JB41&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT2016-1JB41/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2016-1JB41&objecttype=14&gridview=view1 3RT20161JB41 Page 6/7 7/4/2022 Subject to change without notice © Copyright Siemens 5/L3 6/T3 13 3/L2 1/L1 2/T1 4/T2 A1 (+) A2 (-) last modified: 3RT20161JB41 Page 7/7 14 -Q 6/2/2022 7/4/2022 Subject to change without notice © Copyright Siemens
3RT20161JB41 价格&库存

很抱歉,暂时无法提供与“3RT20161JB41”相匹配的价格&库存,您可以联系我们找货

免费人工找货