3RT2017-1BB41

3RT2017-1BB41

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 3RT2017-1BB41 - Contactor, DIN Rail, Panel, 690 V, 3PST-NO, 3 Pole, 5.5 kW

  • 数据手册
  • 价格&库存
3RT2017-1BB41 数据手册
Data sheet 3RT2017-1BB41 power contactor, AC-3e/AC-3, 12 A, 5.5 kW / 400 V, 3-pole, 24 V DC, auxiliary contacts: 1 NO, screw terminal, size: S00 product brand name SIRIUS product designation Power contactor product type designation 3RT2 General technical data size of contactor S00 product extension ● function module for communication No ● auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 1.5 W ● at AC in hot operating state per pole 0.5 W ● without load current share typical 4W type of calculation of power loss depending on pole quadratic insulation voltage ● of main circuit with degree of pollution 3 rated value 690 V ● of auxiliary circuit with degree of pollution 3 rated value 690 V surge voltage resistance ● of main circuit rated value 6 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 400 V shock resistance at rectangular impulse ● at DC 7.3g / 5 ms, 4.7g / 10 ms shock resistance with sine pulse ● at DC 11,4g / 5 ms, 7,3g / 10 ms mechanical service life (operating cycles) ● of contactor typical 30 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 10/01/2009 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -25 ... +60 °C ● during storage -55 ... +80 °C relative humidity minimum 10 % relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 % Environmental footprint 3RT20171BB41 Page 1/8 4/18/2024 Subject to change without notice © Copyright Siemens Environmental Product Declaration(EPD) Yes Global Warming Potential [CO2 eq] total 153 kg Global Warming Potential [CO2 eq] during manufacturing 1.42 kg Global Warming Potential [CO2 eq] during operation 152 kg Global Warming Potential [CO2 eq] after end of life -0.305 kg Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 operating voltage ● at AC-3 rated value maximum 690 V ● at AC-3e rated value maximum 690 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 22 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 22 A — up to 690 V at ambient temperature 60 °C rated value 20 A ● at AC-3 — at 400 V rated value 12 A — at 500 V rated value 9.2 A — at 690 V rated value 6.7 A ● at AC-3e — at 400 V rated value 12 A — at 500 V rated value 9.2 A — at 690 V rated value 6.7 A ● at AC-4 at 400 V rated value 8.5 A ● at AC-5a up to 690 V rated value 19.4 A ● at AC-5b up to 400 V rated value 9.9 A ● at AC-6a — up to 230 V for current peak value n=20 rated value 7.2 A — up to 400 V for current peak value n=20 rated value 7.2 A — up to 500 V for current peak value n=20 rated value 7.2 A — up to 690 V for current peak value n=20 rated value 6.7 A ● at AC-6a — up to 230 V for current peak value n=30 rated value 4.8 A — up to 400 V for current peak value n=30 rated value 4.8 A — up to 500 V for current peak value n=30 rated value 4.8 A — up to 690 V for current peak value n=30 rated value 4.8 A minimum cross-section in main circuit at maximum AC-1 rated value 4 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 4.1 A ● at 690 V rated value 3.3 A operational current ● at 1 current path at DC-1 — at 24 V rated value 20 A — at 60 V rated value 20 A — at 110 V rated value 2.1 A — at 220 V rated value 0.8 A — at 440 V rated value 0.6 A — at 600 V rated value 0.6 A ● with 2 current paths in series at DC-1 — at 24 V rated value 20 A — at 60 V rated value 20 A — at 110 V rated value 12 A — at 220 V rated value 1.6 A — at 440 V rated value 0.8 A — at 600 V rated value 0.7 A ● with 3 current paths in series at DC-1 3RT20171BB41 Page 2/8 4/18/2024 Subject to change without notice © Copyright Siemens — at 24 V rated value 20 A — at 60 V rated value 20 A — at 110 V rated value 20 A — at 220 V rated value 20 A — at 440 V rated value 1.3 A — at 600 V rated value 1A ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 20 A — at 60 V rated value 0.5 A — at 110 V rated value 0.15 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 20 A — at 60 V rated value 5A — at 110 V rated value 0.35 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 20 A — at 60 V rated value 20 A — at 110 V rated value 20 A — at 220 V rated value 1.5 A — at 440 V rated value 0.2 A — at 600 V rated value 0.2 A operating power ● at AC-3 — at 230 V rated value 3 kW — at 400 V rated value 5.5 kW — at 500 V rated value 5.5 kW — at 690 V rated value 5.5 kW ● at AC-3e — at 230 V rated value 3 kW — at 400 V rated value 5.5 kW — at 500 V rated value 5.5 kW — at 690 V rated value 5.5 kW operating power for approx. 200000 operating cycles at AC4 ● at 400 V rated value 2 kW ● at 690 V rated value 2.5 kW operating apparent power at AC-6a ● up to 230 V for current peak value n=20 rated value 2.8 kVA ● up to 400 V for current peak value n=20 rated value 4.9 kVA ● up to 500 V for current peak value n=20 rated value 6.2 kVA ● up to 690 V for current peak value n=20 rated value 8 kVA operating apparent power at AC-6a ● up to 230 V for current peak value n=30 rated value 1.9 kVA ● up to 400 V for current peak value n=30 rated value 3.3 kVA ● up to 500 V for current peak value n=30 rated value 4.1 kVA ● up to 690 V for current peak value n=30 rated value 5.7 kVA short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 200 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 123 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 96 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum 74 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 61 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at DC 10 000 1/h operating frequency ● at AC-1 maximum 1 000 1/h ● at AC-2 maximum 750 1/h ● at AC-3 maximum 750 1/h ● at AC-3e maximum 750 1/h ● at AC-4 maximum 250 1/h 3RT20171BB41 Page 3/8 4/18/2024 Subject to change without notice © Copyright Siemens Control circuit/ Control type of voltage of the control supply voltage DC control supply voltage at DC rated value ● 24 V operating range factor control supply voltage rated value of magnet coil at DC ● initial value 0.8 ● full-scale value 1.1 closing power of magnet coil at DC 4W holding power of magnet coil at DC 4W closing delay ● at DC 30 ... 100 ms opening delay ● at DC 7 ... 13 ms arcing time 10 ... 15 ms control version of the switch operating mechanism Standard A1 - A2 Auxiliary circuit number of NO contacts for auxiliary contacts instantaneous contact 1 operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 10 A ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 11 A ● at 600 V rated value 11 A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 0.5 hp — at 230 V rated value 2 hp ● for 3-phase AC motor — at 200/208 V rated value 3 hp — at 220/230 V rated value 3 hp — at 460/480 V rated value 7.5 hp — at 575/600 V rated value 10 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA) — with type of assignment 2 required gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA) 3RT20171BB41 Page 4/8 4/18/2024 Subject to change without notice © Copyright Siemens ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 height 58 mm width 45 mm depth 73 mm required spacing ● with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm ● for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit screw-type terminals ● at contactor for auxiliary contacts Screw-type terminals ● of magnet coil Screw-type terminals type of connectable conductor cross-sections ● for main contacts — solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² — solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm² — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● for AWG cables for main contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12 connectable conductor cross-section for main contacts ● solid 0.5 ... 4 mm² ● stranded 0.5 ... 4 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² connectable conductor cross-section for auxiliary contacts ● solid or stranded 0.5 ... 4 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● for AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12 AWG number as coded connectable conductor cross section ● for main contacts 20 ... 12 ● for auxiliary contacts 20 ... 12 Safety related data product function ● mirror contact according to IEC 60947-4-1 suitability for use safety-related switching OFF Yes; with 3RH29 Yes; applies only to contactor operating mechanism proportion of dangerous failures ● with low demand rate according to SN 31920 40 % ● with high demand rate according to SN 31920 73 % B10 value with high demand rate according to SN 31920 1 000 000 failure rate [FIT] with low demand rate according to SN 100 FIT 3RT20171BB41 Page 5/8 4/18/2024 Subject to change without notice © Copyright Siemens 31920 IEC 61508 T1 value ● for proof test interval or service life according to IEC 61508 20 a Electrical Safety protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front Approvals Certificates General Product Approval Confirmation General Product Approval EMV Functional Saftey KC Test Certificates Type Examination Certificate Test Certificates Special Test Certificate Type Test Certificates/Test Report Marine / Shipping Miscellaneous Marine / Shipping other Miscellaneous Confirmation Railway Dangerous Good Special Test Certificate Transport Information Environment Environmental Confirmations Further information Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2017-1BB41 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2017-1BB41 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT2017-1BB41 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2017-1BB41&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT2017-1BB41/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2017-1BB41&objecttype=14&gridview=view1 3RT20171BB41 Page 6/8 4/18/2024 Subject to change without notice © Copyright Siemens 3RT20171BB41 Page 7/8 4/18/2024 Subject to change without notice © Copyright Siemens 5/L3 6/T3 13 3/L2 4/T2 1/L1 A1 (+) last modified: 3RT20171BB41 Page 8/8 14 2/T1 A2 -Q 3/15/2024 4/18/2024 Subject to change without notice © Copyright Siemens
3RT2017-1BB41 价格&库存

很抱歉,暂时无法提供与“3RT2017-1BB41”相匹配的价格&库存,您可以联系我们找货

免费人工找货
3RT2017-1BB41
    •  国内价格
    • 1+426.03126
    • 10+359.30347
    • 25+336.20539
    • 50+323.37313

    库存:94

    3RT2017-1BB41
    •  国内价格 香港价格
    • 1+320.555011+39.76470
    • 5+303.065235+37.59510
    • 10+281.6584610+34.93960

    库存:92