3RT20174AR61

3RT20174AR61

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR S00 12A 400VAC 1NO R L

  • 数据手册
  • 价格&库存
3RT20174AR61 数据手册
Data sheet 3RT2017-4AR61 power contactor, AC-3 12 A, 5.5 kW / 400 V 1 NO, 400 V AC, 50 Hz 400440 V, 60 Hz, 3-pole Size S00 ring cable lug connection product brand name SIRIUS product designation Power contactor product type designation 3RT2 General technical data size of contactor S00 product extension ● function module for communication No ● auxiliary switch Yes power loss [W] for rated value of the current at AC in hot operating state ● per pole power loss [W] for rated value of the current without load current share typical 3.6 W 1.2 W 6.5 W surge voltage resistance ● of main circuit rated value 6 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1 400 V shock resistance at rectangular impulse ● at AC 7,3g / 5 ms, 4,7g / 10 ms shock resistance with sine pulse ● at AC 11,4g / 5 ms, 7,3g / 10 ms mechanical service life (switching cycles) ● of contactor typical 30 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.10.2009 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -25 ... +60 °C ● ambient temperature during storage -55 ... +80 °C Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 ● operating voltage at AC-3 rated value maximum 3RT20174AR61 Page 1/2 690 V 1.20.2021 Subject to change without notice © Copyright Siemens operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 22 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 22 A — up to 690 V at ambient temperature 60 °C rated value 20 A ● at AC-3 — at 400 V rated value 12 A — at 500 V rated value 9.2 A — at 690 V rated value 6.7 A ● at AC-4 at 400 V rated value 8.5 A ● at AC-5a up to 690 V rated value 19.4 A ● at AC-5b up to 400 V rated value 9.9 A ● at AC-6a — up to 230 V for current peak value n=20 rated value 7.2 A — up to 400 V for current peak value n=20 rated value 7.2 A — up to 500 V for current peak value n=20 rated value 7.2 A — up to 690 V for current peak value n=20 rated value 6.7 A ● at AC-6a — up to 230 V for current peak value n=30 rated value 4.8 A — up to 400 V for current peak value n=30 rated value 4.8 A — up to 500 V for current peak value n=30 rated value 4.8 A — up to 690 V for current peak value n=30 rated value 4.8 A minimum cross-section in main circuit at maximum AC-1 rated value 4 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 4.1 A ● at 690 V rated value 3.3 A operational current ● at 1 current path at DC-1 — at 24 V rated value 20 A — at 110 V rated value 2.1 A — at 220 V rated value 0.8 A — at 440 V rated value 0.6 A — at 600 V rated value 0.6 A ● with 2 current paths in series at DC-1 — at 24 V rated value 20 A — at 110 V rated value 12 A — at 220 V rated value 1.6 A — at 440 V rated value 0.8 A — at 600 V rated value 0.7 A ● with 3 current paths in series at DC-1 — at 24 V rated value 20 A — at 110 V rated value 20 A — at 220 V rated value 20 A — at 440 V rated value 1.3 A — at 600 V rated value 1A operational current ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 3RT20174AR61 Page 2/3 20 A 1.20.2021 Subject to change without notice © Copyright Siemens — at 110 V rated value 0.1 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 20 A — at 110 V rated value 0.35 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 20 A — at 110 V rated value 20 A — at 220 V rated value 1.5 A — at 440 V rated value 0.2 A — at 600 V rated value 0.2 A operating power ● at AC-3 — at 230 V rated value 3 kW — at 400 V rated value 5.5 kW — at 500 V rated value 5.5 kW — at 690 V rated value 5.5 kW operating power for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 2 kW ● at 690 V rated value 2.5 kW operating apparent power at AC-6a ● up to 230 V for current peak value n=20 rated value 2.8 kV·A ● up to 400 V for current peak value n=20 rated value 4.9 kV·A ● up to 500 V for current peak value n=20 rated value 6.2 kV·A ● up to 690 V for current peak value n=20 rated value 8 kV·A operating apparent power at AC-6a ● up to 230 V for current peak value n=30 rated value 1.9 kV·A ● up to 400 V for current peak value n=30 rated value 3.3 kV·A ● up to 500 V for current peak value n=30 rated value 4.1 kV·A ● up to 690 V for current peak value n=30 rated value 5.7 kV·A short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 200 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 123 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 96 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum 74 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 61 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at AC 10 000 1/h operating frequency ● at AC-1 maximum 1 000 1/h ● at AC-2 maximum 750 1/h ● at AC-3 maximum 750 1/h ● at AC-4 maximum 250 1/h Control circuit/ Control type of voltage of the control supply voltage AC control supply voltage at AC ● at 50 Hz rated value 400 V ● at 60 Hz rated value 440 V operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 ● at 60 Hz 0.85 ... 1.1 apparent pick-up power of magnet coil at AC ● at 50 Hz 36 V·A ● at 60 Hz 43 V·A inductive power factor with closing power of the coil ● at 50 Hz 0.8 ● at 60 Hz 0.8 3RT20174AR61 Page 3/4 1.20.2021 Subject to change without notice © Copyright Siemens apparent holding power of magnet coil at AC ● at 50 Hz 5.9 V·A ● at 60 Hz 6.5 V·A inductive power factor with the holding power of the coil ● at 50 Hz 0.24 ● at 60 Hz 0.25 closing delay ● at AC 8 ... 33 ms opening delay ● at AC 4 ... 15 ms arcing time 10 ... 15 ms control version of the switch operating mechanism Standard A1 - A2 Auxiliary circuit number of NO contacts for auxiliary contacts instantaneous contact 1 operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 10 A ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 11 A ● at 600 V rated value 11 A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 0.5 hp — at 230 V rated value 2 hp ● for 3-phase AC motor — at 200/208 V rated value 3 hp — at 220/230 V rated value 3 hp — at 460/480 V rated value 7.5 hp — at 575/600 V rated value 10 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA) — with type of assignment 2 required gG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA) 3RT20174AR61 Page 4/5 1.20.2021 Subject to change without notice © Copyright Siemens ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 ● side-by-side mounting Yes height 58 mm width 45 mm depth 73 mm required spacing ● with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm ● for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection ● for main current circuit Ring cable lug connection ● for auxiliary and control circuit ring cable connection ● at contactor for auxiliary contacts Ring cable lug connection ● of magnet coil Ring cable lug connection Safety related data B10 value with high demand rate acc. to SN 31920 1 000 000 proportion of dangerous failures ● with low demand rate acc. to SN 31920 40 % ● with high demand rate acc. to SN 31920 73 % failure rate [FIT] with low demand rate acc. to SN 31920 100 FIT product function ● mirror contact acc. to IEC 60947-4-1 Yes; with 3RH29 T1 value for proof test interval or service life acc. to IEC 61508 20 y protection class IP on the front acc. to IEC 60529 IP00 suitability for use safety-related switching OFF Yes Certificates/ approvals General Product Approval EMC KC Declaration of Conformity 3RT20174AR61 Page 5/6 Test Certificates 1.20.2021 Marine / Shipping Subject to change without notice © Copyright Siemens Miscellaneous Special Test Certificate Type Test Certificates/Test Report Marine / Shipping other Confirmation other Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2017-4AR61 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2017-4AR61 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT2017-4AR61 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2017-4AR61&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT2017-4AR61/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2017-4AR61&objecttype=14&gridview=view1 3RT20174AR61 Page 6/7 1.20.2021 Subject to change without notice © Copyright Siemens 3RT20174AR61 Page 7/8 1.20.2021 Subject to change without notice © Copyright Siemens 3RT20174AR61 Page 8/9 1.20.2021 Subject to change without notice © Copyright Siemens last modified: 1/6/2021 3RT20174AR61 Page 9/9 1.20.2021 Subject to change without notice © Copyright Siemens
3RT20174AR61 价格&库存

很抱歉,暂时无法提供与“3RT20174AR61”相匹配的价格&库存,您可以联系我们找货

免费人工找货