Data sheet
3RT2028-4AP60
Power contactor, AC-3 38 A, 18.5 kW / 400 V 1 NO + 1 NC, 220 V AC 50
Hz, 240 V, 60Hz, 3-pole, size S0 ring cable lug connection
product brand name
SIRIUS
product designation
Power contactor
product type designation
3RT2
General technical data
size of contactor
S0
product extension
● function module for communication
No
● auxiliary switch
Yes
power loss [W] for rated value of the current at AC in hot
operating state
● per pole
power loss [W] for rated value of the current without
load current share typical
11.4 W
3.8 W
10.5 W
surge voltage resistance
● of main circuit rated value
6 kV
● of auxiliary circuit rated value
6 kV
maximum permissible voltage for safe isolation between
coil and main contacts acc. to EN 60947-1
400 V
shock resistance at rectangular impulse
● at AC
8,3g / 5 ms, 5,3g / 10 ms
shock resistance with sine pulse
● at AC
13,5g / 5 ms, 8,3g / 10 ms
mechanical service life (switching cycles)
● of contactor typical
10 000 000
● of the contactor with added electronically optimized
auxiliary switch block typical
5 000 000
● of the contactor with added auxiliary switch block
typical
10 000 000
reference code acc. to IEC 81346-2
Q
Substance Prohibitance (Date)
01.10.2009 00:00:00
Ambient conditions
installation altitude at height above sea level maximum
2 000 m
● ambient temperature during operation
-25 ... +60 °C
● ambient temperature during storage
-55 ... +80 °C
Main circuit
number of poles for main current circuit
3
number of NO contacts for main contacts
3
● operating voltage at AC-3 rated value maximum
3RT20284AP60
Page 1/2
690 V
1.20.2021
Subject to change without notice
© Copyright Siemens
operational current
● at AC-1 at 400 V at ambient temperature 40 °C
rated value
50 A
● at AC-1
— up to 690 V at ambient temperature 40 °C
rated value
50 A
— up to 690 V at ambient temperature 60 °C
rated value
42 A
● at AC-3
— at 400 V rated value
38 A
— at 500 V rated value
32 A
— at 690 V rated value
21 A
● at AC-4 at 400 V rated value
22 A
● at AC-5a up to 690 V rated value
44 A
● at AC-5b up to 400 V rated value
31.5 A
● at AC-6a
— up to 230 V for current peak value n=20 rated
value
30.8 A
— up to 400 V for current peak value n=20 rated
value
30.8 A
— up to 500 V for current peak value n=20 rated
value
30.8 A
— up to 690 V for current peak value n=20 rated
value
21 A
● at AC-6a
— up to 230 V for current peak value n=30 rated
value
20.5 A
— up to 400 V for current peak value n=30 rated
value
20.5 A
— up to 500 V for current peak value n=30 rated
value
21.4 A
— up to 690 V for current peak value n=30 rated
value
21 A
minimum cross-section in main circuit at maximum AC-1
rated value
10 mm²
operational current for approx. 200000 operating
cycles at AC-4
● at 400 V rated value
12 A
● at 690 V rated value
12 A
operational current
● at 1 current path at DC-1
— at 24 V rated value
35 A
— at 110 V rated value
4.5 A
— at 220 V rated value
1A
— at 440 V rated value
0.4 A
— at 600 V rated value
0.25 A
● with 2 current paths in series at DC-1
— at 24 V rated value
35 A
— at 110 V rated value
35 A
— at 220 V rated value
5A
— at 440 V rated value
1A
— at 600 V rated value
0.8 A
● with 3 current paths in series at DC-1
— at 24 V rated value
35 A
— at 110 V rated value
35 A
— at 220 V rated value
35 A
— at 440 V rated value
2.9 A
— at 600 V rated value
1.4 A
operational current
● at 1 current path at DC-3 at DC-5
— at 24 V rated value
3RT20284AP60
Page 2/3
20 A
1.20.2021
Subject to change without notice
© Copyright Siemens
— at 110 V rated value
2.5 A
— at 220 V rated value
1A
— at 440 V rated value
0.09 A
— at 600 V rated value
0.06 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value
35 A
— at 110 V rated value
15 A
— at 220 V rated value
3A
— at 440 V rated value
0.27 A
— at 600 V rated value
0.16 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value
35 A
— at 110 V rated value
35 A
— at 220 V rated value
10 A
— at 440 V rated value
0.6 A
— at 600 V rated value
0.6 A
operating power
● at AC-2 at 400 V rated value
18.5 kW
● at AC-3
— at 230 V rated value
11 kW
— at 400 V rated value
18.5 kW
— at 500 V rated value
18.5 kW
— at 690 V rated value
18.5 kW
operating power for approx. 200000 operating cycles
at AC-4
● at 400 V rated value
6 kW
● at 690 V rated value
10.3 kW
operating apparent power at AC-6a
● up to 230 V for current peak value n=20 rated value
12.2 kV·A
● up to 400 V for current peak value n=20 rated value
21.3 kV·A
● up to 500 V for current peak value n=20 rated value
26.6 kV·A
● up to 690 V for current peak value n=20 rated value
25 kV·A
operating apparent power at AC-6a
● up to 230 V for current peak value n=30 rated value
8.1 kV·A
● up to 400 V for current peak value n=30 rated value
14.2 kV·A
● up to 500 V for current peak value n=30 rated value
18.5 kV·A
● up to 690 V for current peak value n=30 rated value
25 kV·A
short-time withstand current in cold operating state
up to 40 °C
● limited to 1 s switching at zero current maximum
593 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum
395 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 10 s switching at zero current maximum
260 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum
186 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum
152 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency
● at AC
5 000 1/h
operating frequency
● at AC-1 maximum
1 000 1/h
● at AC-2 maximum
750 1/h
● at AC-3 maximum
750 1/h
● at AC-4 maximum
250 1/h
Control circuit/ Control
type of voltage of the control supply voltage
AC
control supply voltage at AC
● at 50 Hz rated value
220 V
● at 60 Hz rated value
240 V
operating range factor control supply voltage rated
value of magnet coil at AC
● at 50 Hz
3RT20284AP60
Page 3/4
0.8 ... 1.1
1.20.2021
Subject to change without notice
© Copyright Siemens
● at 60 Hz
0.8 ... 1.1
apparent pick-up power of magnet coil at AC
● at 50 Hz
81 V·A
● at 60 Hz
79 V·A
inductive power factor with closing power of the coil
● at 50 Hz
0.72
● at 60 Hz
0.74
apparent holding power of magnet coil at AC
● at 50 Hz
10.5 V·A
● at 60 Hz
8.5 V·A
inductive power factor with the holding power of the
coil
● at 50 Hz
0.25
● at 60 Hz
0.28
closing delay
● at AC
8 ... 40 ms
opening delay
● at AC
4 ... 16 ms
arcing time
10 ... 10 ms
control version of the switch operating mechanism
Standard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts
instantaneous contact
1
number of NO contacts for auxiliary contacts
instantaneous contact
1
operational current at AC-12 maximum
10 A
operational current at AC-15
● at 230 V rated value
10 A
● at 400 V rated value
3A
● at 500 V rated value
2A
● at 690 V rated value
1A
operational current at DC-12
● at 24 V rated value
10 A
● at 48 V rated value
6A
● at 60 V rated value
6A
● at 110 V rated value
3A
● at 125 V rated value
2A
● at 220 V rated value
1A
● at 600 V rated value
0.15 A
operational current at DC-13
● at 24 V rated value
10 A
● at 48 V rated value
2A
● at 60 V rated value
2A
● at 110 V rated value
1A
● at 125 V rated value
0.9 A
● at 220 V rated value
0.3 A
● at 600 V rated value
0.1 A
contact reliability of auxiliary contacts
1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value
34 A
● at 600 V rated value
27 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value
3 hp
— at 230 V rated value
5 hp
● for 3-phase AC motor
— at 200/208 V rated value
10 hp
— at 220/230 V rated value
10 hp
3RT20284AP60
Page 4/5
1.20.2021
Subject to change without notice
© Copyright Siemens
— at 460/480 V rated value
25 hp
— at 575/600 V rated value
25 hp
contact rating of auxiliary contacts according to UL
A600 / P600
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 required
gG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A
(415V,80kA)
— with type of assignment 2 required
gG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V,
80kA)
● for short-circuit protection of the auxiliary switch
required
gG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position
+/-180° rotation possible on vertical mounting surface; can be tilted
forward and backward by +/- 22.5° on vertical mounting surface
fastening method
screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
● side-by-side mounting
Yes
height
85 mm
width
45 mm
depth
97 mm
required spacing
● with side-by-side mounting
— forwards
10 mm
— upwards
10 mm
— downwards
10 mm
— at the side
0 mm
● for grounded parts
— forwards
10 mm
— upwards
10 mm
— at the side
6 mm
— downwards
10 mm
● for live parts
— forwards
10 mm
— upwards
10 mm
— downwards
10 mm
— at the side
6 mm
Connections/ Terminals
type of electrical connection
● for main current circuit
Ring cable lug connection
● for auxiliary and control circuit
ring cable connection
● at contactor for auxiliary contacts
Ring cable lug connection
● of magnet coil
Ring cable lug connection
Safety related data
B10 value with high demand rate acc. to SN 31920
1 000 000
proportion of dangerous failures
● with low demand rate acc. to SN 31920
40 %
● with high demand rate acc. to SN 31920
73 %
failure rate [FIT] with low demand rate acc. to SN 31920
100 FIT
product function
● mirror contact acc. to IEC 60947-4-1
Yes
T1 value for proof test interval or service life acc. to
IEC 61508
20 y
protection class IP on the front acc. to IEC 60529
IP00
suitability for use safety-related switching OFF
Yes
Certificates/ approvals
General Product Approval
3RT20284AP60
Page 5/6
EMC
1.20.2021
Subject to change without notice
© Copyright Siemens
KC
Declaration of Conformity
Miscellaneous
Test Certificates
Type Test
Certificates/Test
Report
Marine / Shipping
Special Test
Certificate
Marine / Shipping
other
Confirmation
other
Confirmation
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2028-4AP60
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2028-4AP60
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RT2028-4AP60
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2028-4AP60&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RT2028-4AP60/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2028-4AP60&objecttype=14&gridview=view1
3RT20284AP60
Page 6/7
1.20.2021
Subject to change without notice
© Copyright Siemens
3RT20284AP60
Page 7/8
1.20.2021
Subject to change without notice
© Copyright Siemens
3RT20284AP60
Page 8/9
1.20.2021
Subject to change without notice
© Copyright Siemens
last modified:
1/6/2021
3RT20284AP60
Page 9/9
1.20.2021
Subject to change without notice
© Copyright Siemens