Data sheet
3RT2037-3XF40-0LA2
Traction contactor, AC-3 65 A, 30 kW / 400 V 1 NO + 1 NC 110 V DC, 0.71.25* Us with varistor 3-pole, size S2 Spring-type terminals
product brand name
SIRIUS
product designation
Contactor
design of the product
With extended operating range
product type designation
3RT2
General technical data
size of contactor
S2
product extension
● function module for communication
No
● auxiliary switch
Yes
power loss [W] for rated value of the current at AC in hot
operating state
● per pole
power loss [W] for rated value of the current without
load current share typical
11.4 W
3.8 W
1W
insulation voltage
● of main circuit with degree of pollution 3 rated value
690 V
● of auxiliary circuit with degree of pollution 3 rated
value
690 V
surge voltage resistance
● of main circuit rated value
6 kV
● of auxiliary circuit rated value
6 kV
maximum permissible voltage for safe isolation between
coil and main contacts acc. to EN 60947-1
400 V
shock resistance at rectangular impulse
● at DC
7.7g / 5 ms, 4.5g / 10 ms
shock resistance with sine pulse
● at DC
12g / 5 ms, 7g / 10 ms
mechanical service life (switching cycles)
● of contactor typical
10 000 000
● of the contactor with added electronically optimized
auxiliary switch block typical
5 000 000
● of the contactor with added auxiliary switch block
typical
10 000 000
reference code acc. to IEC 81346-2
Q
Substance Prohibitance (Date)
01.10.2014 00:00:00
Ambient conditions
installation altitude at height above sea level maximum
2 000 m
● ambient temperature during operation
-40 ... +70 °C
● ambient temperature during storage
-55 ... +80 °C
3RT20373XF400LA2
Page 1/2
1.21.2021
Subject to change without notice
© Copyright Siemens
Main circuit
number of poles for main current circuit
3
number of NO contacts for main contacts
3
● operating voltage at AC-3 rated value maximum
690 V
operational current
● at AC-1 at 400 V at ambient temperature 40 °C
rated value
80 A
● at AC-1
— up to 690 V at ambient temperature 40 °C
rated value
80 A
— up to 690 V at ambient temperature 60 °C
rated value
70 A
● at AC-2 at 400 V rated value
65 A
● at AC-3
— at 400 V rated value
65 A
— at 500 V rated value
65 A
— at 690 V rated value
47 A
● at AC-4 at 400 V rated value
55 A
minimum cross-section in main circuit
● at maximum AC-1 rated value
25 mm²
● at maximum Ith rated value
25 mm²
operational current for approx. 200000 operating
cycles at AC-4
● at 400 V rated value
28 A
● at 690 V rated value
22 A
operational current
● at 1 current path at DC-1
— at 24 V rated value
55 A
— at 110 V rated value
4.5 A
— at 220 V rated value
1A
— at 440 V rated value
0.4 A
— at 600 V rated value
0.25 A
● with 2 current paths in series at DC-1
— at 24 V rated value
55 A
— at 110 V rated value
45 A
— at 220 V rated value
5A
— at 440 V rated value
1A
— at 600 V rated value
0.8 A
● with 3 current paths in series at DC-1
— at 24 V rated value
55 A
— at 110 V rated value
55 A
— at 220 V rated value
45 A
— at 440 V rated value
2.9 A
— at 600 V rated value
1.4 A
operational current
● at 1 current path at DC-3 at DC-5
— at 24 V rated value
35 A
— at 110 V rated value
2.5 A
— at 220 V rated value
1A
— at 440 V rated value
0.1 A
— at 600 V rated value
0.06 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value
55 A
— at 110 V rated value
25 A
— at 220 V rated value
5A
— at 440 V rated value
0.27 A
— at 600 V rated value
0.16 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value
3RT20373XF400LA2
Page 2/3
55 A
1.21.2021
Subject to change without notice
© Copyright Siemens
— at 110 V rated value
55 A
— at 220 V rated value
25 A
— at 440 V rated value
0.6 A
— at 600 V rated value
0.35 A
operating power
● at AC-2 at 400 V rated value
30 kW
● at AC-3
— at 230 V rated value
18.5 kW
— at 400 V rated value
30 kW
— at 500 V rated value
37 kW
— at 690 V rated value
37 kW
operating power for approx. 200000 operating cycles
at AC-4
● at 400 V rated value
14.7 kW
● at 690 V rated value
20 kW
short-time withstand current in cold operating state
up to 40 °C
● limited to 1 s switching at zero current maximum
1 055 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum
730 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 10 s switching at zero current maximum
520 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum
336 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum
272 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency
● at DC
1 500 1/h
Ratings for railway applications
thermal current (Ith) up to 690 V
● up to 40 °C according to IEC 60077 rated value
80 A
● up to 70 °C according to IEC 60077 rated value
60 A
Control circuit/ Control
type of voltage
DC
type of voltage of the control supply voltage
DC
control supply voltage at DC
● rated value
110 V
operating range factor control supply voltage rated
value of magnet coil at DC
● initial value
0.7
● full-scale value
1.25
design of the surge suppressor
with varistor
inrush current peak
1.5 A
duration of inrush current peak
50 µs
locked-rotor current mean value
0.45 A
locked-rotor current peak
0.8 A
duration of locked-rotor current
230 ms
holding current mean value
12 mA
closing power of magnet coil at DC
23 W
holding power of magnet coil at DC
1W
closing delay
● at DC
45 ... 60 ms
opening delay
● at DC
35 ... 55 ms
arcing time
10 ... 20 ms
control version of the switch operating mechanism
Standard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts
● instantaneous contact
number of NO contacts for auxiliary contacts
● instantaneous contact
operational current at AC-12 maximum
1
1
1
1
10 A
operational current at AC-15
3RT20373XF400LA2
Page 3/4
1.21.2021
Subject to change without notice
© Copyright Siemens
● at 230 V rated value
10 A
● at 400 V rated value
3A
● at 500 V rated value
2A
● at 690 V rated value
1A
operational current at DC-12
● at 24 V rated value
10 A
● at 48 V rated value
6A
● at 60 V rated value
6A
● at 110 V rated value
3A
● at 125 V rated value
2A
● at 220 V rated value
1A
● at 600 V rated value
0.15 A
operational current at DC-13
● at 24 V rated value
10 A
● at 48 V rated value
2A
● at 60 V rated value
2A
● at 110 V rated value
1A
● at 125 V rated value
0.9 A
● at 220 V rated value
0.3 A
● at 600 V rated value
0.1 A
contact reliability of auxiliary contacts
1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value
65 A
● at 600 V rated value
52 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value
5 hp
— at 230 V rated value
10 hp
● for 3-phase AC motor
— at 200/208 V rated value
20 hp
— at 220/230 V rated value
20 hp
— at 460/480 V rated value
50 hp
— at 575/600 V rated value
50 hp
contact rating of auxiliary contacts according to UL
A600 / P600
Short-circuit protection
product function short circuit protection
No
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 required
gG: 250 A (690 V, 100 kA), aM: 160 A (690 V, 100 kA), BS88: 200 A
(415 V, 80 kA)
— with type of assignment 2 required
gG: 125A (690V,100kA), aM: 63A (690V,100kA), BS88: 100A
(415V,80kA)
● for short-circuit protection of the auxiliary switch
required
gG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position
+/-180° rotation possible on vertical mounting surface; can be tilted
forward and backward by +/- 22.5° on vertical mounting surface
fastening method
screw and snap-on mounting onto 35 mm standard mounting rail
according to DIN EN 60715
● side-by-side mounting
Yes
height
114 mm
width
55 mm
depth
130 mm
required spacing
● with side-by-side mounting
— forwards
10 mm
— upwards
10 mm
— downwards
10 mm
3RT20373XF400LA2
Page 4/5
1.21.2021
Subject to change without notice
© Copyright Siemens
— at the side
0 mm
● for grounded parts
— forwards
10 mm
— upwards
10 mm
— at the side
6 mm
— downwards
10 mm
● for live parts
— forwards
10 mm
— upwards
10 mm
— downwards
10 mm
— at the side
6 mm
Connections/ Terminals
type of electrical connection
● for main current circuit
screw-type terminals
● for auxiliary and control circuit
spring-loaded terminals
● at contactor for auxiliary contacts
Spring-type terminals
● of magnet coil
Spring-type terminals
type of connectable conductor cross-sections
● for main contacts
— solid or stranded
2x (1 ... 35 mm²), 1x (1 ... 50 mm²)
— finely stranded with core end processing
2x (1 ... 25 mm²), 1x (1 ... 35 mm²)
● at AWG cables for main contacts
2x (18 ... 2), 1x (18 ... 1)
type of connectable conductor cross-sections
● for auxiliary contacts
— solid or stranded
2x (0.5 ... 2.5 mm²)
— finely stranded with core end processing
2x (0.5 ... 1.5 mm²)
— finely stranded without core end processing
2x (0.5 ... 2.5 mm²)
● at AWG cables for auxiliary contacts
2x (20 ... 14)
● AWG number as coded connectable conductor
cross section for main contacts
18 ... 1
● AWG number as coded connectable conductor
cross section for auxiliary contacts
20 ... 14
Safety related data
B10 value with high demand rate acc. to SN 31920
1 000 000
proportion of dangerous failures
● with low demand rate acc. to SN 31920
40 %
● with high demand rate acc. to SN 31920
73 %
failure rate [FIT] with low demand rate acc. to SN 31920
100 FIT
product function
● mirror contact acc. to IEC 60947-4-1
Yes
● positively driven operation acc. to IEC 60947-5-1
No
T1 value for proof test interval or service life acc. to
IEC 61508
20 y
protection class IP on the front acc. to IEC 60529
IP20
touch protection on the front acc. to IEC 60529
finger-safe, for vertical contact from the front
suitability for use safety-related switching OFF
Yes
Communication/ Protocol
product function bus communication
No
Certificates/ approvals
General Product Approval
EMC
KC
Declaration of Conformity
3RT20373XF400LA2
Page 5/6
Test Certificates
1.21.2021
Marine / Shipping
Subject to change without notice
© Copyright Siemens
Miscellaneous
Type Test
Certificates/Test
Report
Special Test
Certificate
Marine / Shipping
other
Confirmation
Railway
Type Test
Certificates/Test
Report
Vibration and Shock
Special Test
Certificate
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2037-3XF40-0LA2
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2037-3XF40-0LA2
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RT2037-3XF40-0LA2
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2037-3XF40-0LA2&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RT2037-3XF40-0LA2/char
Further characteristics (e.g. electrical endurance, switching frequency)
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2037-3XF40-0LA2&objecttype=14&gridview=view1
3RT20373XF400LA2
Page 6/7
1.21.2021
Subject to change without notice
© Copyright Siemens
3RT20373XF400LA2
Page 7/8
1.21.2021
Subject to change without notice
© Copyright Siemens
last modified:
3RT20373XF400LA2
Page 8/8
12/15/2020
1.21.2021
Subject to change without notice
© Copyright Siemens