3RT23371AP60

3RT23371AP60

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR RES S2 105A 4P 240VAC

  • 数据手册
  • 价格&库存
3RT23371AP60 数据手册
Data sheet 3RT2337-1AP60 Contactor, AC-1, 110 A/400 V/40 °C, S2, 4-pole, 220 V AC/50 Hz, 240 V/60 Hz, 1 NO+1 NC, screw terminal product brand name SIRIUS product designation Contactor product type designation 3RT23 General technical data size of contactor S2 product extension ● function module for communication No ● auxiliary switch Yes surge voltage resistance ● of main circuit rated value 6 kV ● of auxiliary circuit rated value 6 kV shock resistance at rectangular impulse ● at AC 11.8g / 5 ms, 7.4g / 10 ms shock resistance with sine pulse ● at AC 18.5g / 5 ms, 11.6g / 10 ms mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added auxiliary switch block typical 100 000 000 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.10.2014 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -40 ... +70 °C ● ambient temperature during storage -55 ... +80 °C relative humidity during operation 95 % Main circuit number of poles for main current circuit 4 number of NO contacts for main contacts 4 ● operating voltage at AC — at 50 Hz rated value 690 V — at 60 Hz rated value 690 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 110 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 3RT23371AP60 Page 1/2 110 A 1.21.2021 Subject to change without notice © Copyright Siemens — up to 690 V at ambient temperature 60 °C rated value ● at AC-3 at 400 V rated value minimum cross-section in main circuit at maximum AC-1 rated value 95 A 38 A 35 mm² short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at AC operating frequency at AC-1 maximum 5 000 1/h 700 1/h Control circuit/ Control type of voltage AC type of voltage of the control supply voltage AC ● control supply voltage at AC at 50 Hz rated value 220 V ● control supply voltage at AC at 60 Hz rated value 240 V operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 ● at 60 Hz 0.8 ... 1.1 apparent pick-up power of magnet coil at AC ● at 50 Hz 212 V·A ● at 60 Hz 188 V·A inductive power factor with closing power of the coil ● at 50 Hz 0.69 ● at 60 Hz 0.65 apparent holding power of magnet coil at AC ● at 50 Hz 18.5 V·A ● at 60 Hz 16.5 V·A inductive power factor with the holding power of the coil ● at 50 Hz 0.36 ● at 60 Hz 0.39 closing delay ● at AC 10 ... 80 ms opening delay ● at AC 10 ... 18 ms arcing time 10 ... 20 ms control version of the switch operating mechanism Standard A1 - A2 Auxiliary circuit number of NC contacts for auxiliary contacts 1 ● attachable 2 ● instantaneous contact 1 number of NO contacts for auxiliary contacts 1 ● attachable 2 ● instantaneous contact 1 operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A 3RT23371AP60 Page 2/3 1.21.2021 Subject to change without notice © Copyright Siemens ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 10 A ● at 48 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A design of the miniature circuit breaker for short-circuit protection of the auxiliary switch required gG: 10 A (230 V, 400 A) contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings contact rating of auxiliary contacts according to UL A600 / P600 Short-circuit protection product function short circuit protection No design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 160 A (690 V, 100 kA) — with type of assignment 2 required gR: 80 A (690 V, 100 kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (690 V, 1 kA) Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 ● side-by-side mounting Yes height 114 mm width 75 mm depth 130 mm required spacing ● with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm ● for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit screw-type terminals type of connectable conductor cross-sections ● for main contacts — solid or stranded 2x (1 ... 35 mm²), 1x (1 ... 50 mm²) — finely stranded with core end processing 2x (1 ... 25 mm²), 1x (1 ... 35 mm²) ● at AWG cables for main contacts 3RT23371AP60 Page 3/4 2x (18 ... 2), 1x (18 ... 1) 1.21.2021 Subject to change without notice © Copyright Siemens connectable conductor cross-section for main contacts ● solid or stranded 1 ... 50 mm² ● finely stranded with core end processing 1 ... 35 mm² connectable conductor cross-section for auxiliary contacts ● solid or stranded 0.5 ... 2.5 mm² ● finely stranded with core end processing 0.5 ... 2.5 mm² ● finely stranded without core end processing 0.5 ... 2.5 mm² type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) — solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14) ● AWG number as coded connectable conductor cross section for main contacts 18 ... 1 ● AWG number as coded connectable conductor cross section for auxiliary contacts 20 ... 14 Safety related data product function ● mirror contact acc. to IEC 60947-4-1 Yes ● positively driven operation acc. to IEC 60947-5-1 No T1 value for proof test interval or service life acc. to IEC 61508 20 y protection class IP on the front acc. to IEC 60529 IP20 touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front Communication/ Protocol product function bus communication No Certificates/ approvals General Product Approval EMC KC Declaration of Conformity Miscellaneous Test Certificates Type Test Certificates/Test Report Marine / Shipping Special Test Certificate Marine / Shipping other Confirmation Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2337-1AP60 Cax online generator 3RT23371AP60 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2337-1AP60 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT2337-1AP60 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2337-1AP60&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT2337-1AP60/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2337-1AP60&objecttype=14&gridview=view1 3RT23371AP60 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 3RT23371AP60 Page 6/6 12/15/2020 1.21.2021 Subject to change without notice © Copyright Siemens
3RT23371AP60 价格&库存

很抱歉,暂时无法提供与“3RT23371AP60”相匹配的价格&库存,您可以联系我们找货

免费人工找货