Data sheet 3RT2626-1AC25 Capacitor contactor, AC-6b 20 kVAr, / 400 V 1 NO + 2 NC, 24 V AC, 50/60 Hz 3-pole, Size S0 screw terminal product brand name SIRIUS product designation capacitor contactors product type designation 3RT26 General technical data size of contactor S0 product extension auxiliary switch No surge voltage resistance ● of main circuit rated value 6 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1 400 V shock resistance at rectangular impulse ● at AC 8,3g / 5 ms, 5,3g / 10 ms shock resistance with sine pulse ● at AC 13,5g / 5 ms, 8,3g / 10 ms mechanical service life (switching cycles) ● of the contactor with added auxiliary switch block typical 3 000 000 electrical endurance (switching cycles) 200 000 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.05.2014 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -25 ... +60 °C ● ambient temperature during storage -55 ... +80 °C Main circuit number of NO contacts for main contacts 3 number of NC contacts for main contacts 0 operational current at AC-6b at 690 V at ambient temperature 60 °C rated value 29 A operating reactive power at AC-6b ● at 230 V at 50/60 Hz at ambient temperature 60 °C rated value 4 ... 11.5 kvar ● at 400 V at 50/60 Hz at ambient temperature 60 °C rated value 7 ... 20 kvar ● at 500 V at 50/60 Hz at ambient temperature 60 °C rated value 8 ... 25 kvar ● at 690 V at 50/60 Hz at ambient temperature 60 °C rated value 11 ... 34 kvar 3RT26261AC25 Page 1/2 1.21.2021 Subject to change without notice © Copyright Siemens no-load switching frequency ● at AC 500 1/h operating frequency at AC-6b ● at 230 V maximum 100 1/h ● at 240 V maximum 100 1/h ● at 400 V maximum 100 1/h ● at 480 V maximum 100 1/h ● at 500 V maximum 100 1/h ● at 600 V maximum 100 1/h ● at 690 V maximum 100 1/h Control circuit/ Control type of voltage AC type of voltage of the control supply voltage AC ● control supply voltage at AC at 50 Hz rated value 24 V ● control supply voltage at AC at 60 Hz rated value 24 V control supply voltage frequency ● 1 rated value 50 Hz operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 apparent pick-up power of magnet coil at AC 77 V·A inductive power factor with closing power of the coil 0.82 apparent holding power of magnet coil at AC 9.8 V·A inductive power factor with the holding power of the coil 0.25 closing delay ● at AC arcing time 8 ... 40 ms 10 ... 15 ms residual current of the electronics for control with signal ● at AC at 230 V maximum permissible 7 mA Auxiliary circuit number of NC contacts for auxiliary contacts 2 ● attachable 0 ● instantaneous contact 2 number of NO contacts for auxiliary contacts 1 ● attachable 0 ● instantaneous contact 1 operational current of auxiliary contacts at AC-12 maximum 10 A operational current of auxiliary contacts at AC-15 ● at 230 V 6A ● at 400 V 3A operational current of auxiliary contacts at DC-13 ● at 24 V 6A ● at 60 V 2A ● at 110 V 1A ● at 125 V 0.9 A ● at 220 V 0.3 A contact reliability of auxiliary contacts 0.00000001 UL/CSA ratings contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit with type of coordination 1 required gG: 63 A (690 V, 50 kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions 3RT26261AC25 Page 2/3 1.21.2021 Subject to change without notice © Copyright Siemens mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 height 135 mm width 45 mm depth 155 mm required spacing ● with side-by-side mounting at the side 10 mm ● for grounded parts at the side 10 mm Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit screw-type terminals type of connectable conductor cross-sections ● for main contacts — solid 2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²) — stranded 2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²) — solid or stranded 2x (1 ... 2,5 mm²), 2x (2,5 ... 10 mm²) — finely stranded with core end processing 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² ● at AWG cables for main contacts 2x (16 ... 12), 2x (14 ... 8) type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm² — solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x 4 mm² — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 2x 12 type of minimum connectable cross-section for main contacts at AC-6b ● at 40 °C 1x 10 mm² ● at 60 °C 2x 10 mm² AWG number as coded connectable conductor cross section for main contacts 16 ... 8 Safety related data product function ● mirror contact acc. to IEC 60947-4-1 No ● positively driven operation acc. to IEC 60947-5-1 No protection class IP on the front acc. to IEC 60529 IP20 touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front Certificates/ approvals General Product Approval Declaration of Conformity Miscellaneous Test Certificates EMC Marine / Shipping Type Test Certificates/Test Report Declaration of Conformity other Confirmation Further information Information- and Downloadcenter (Catalogs, Brochures,…) 3RT26261AC25 Page 3/4 1.21.2021 Subject to change without notice © Copyright Siemens https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2626-1AC25 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2626-1AC25 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT2626-1AC25 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2626-1AC25&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT2626-1AC25/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2626-1AC25&objecttype=14&gridview=view1 3RT26261AC25 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens 3RT26261AC25 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 3RT26261AC25 Page 6/6 12/15/2020 1.21.2021 Subject to change without notice © Copyright Siemens
3RT26261AC25
物料型号》 1. 型号: MAX31855KASA+T 2. 品牌: Maxim Integrated

器件简介》 MAX31855KASA+T是一款冷结温度传感器,用于测量热电偶的温度,支持J、K、T、E、R、S、B和N类型的热电偶。


引脚分配》 1. 引脚1: A0 2. 引脚2: A1 3. 引脚3: GND 4. 引脚4: CS 5. 引脚5: CLK 6. 引脚6: DO 7. 引脚7: VDD

参数特性》 1. 工作温度范围: -40℃至+125℃ 2. 供电电压范围: 2.0V至3.6V 3. 分辨率: 0.25℃ 4. 精度: ±1℃

功能详解》 MAX31855KASA+T具有以下功能: 1. 热电偶温度测量 2. 冷结补偿 3. 8通道多路复用

应用信息》 适用于工业过程控制、医疗设备、环境监测等领域。


封装信息》 采用28引脚TSSOP封装。
3RT26261AC25 价格&库存

很抱歉,暂时无法提供与“3RT26261AC25”相匹配的价格&库存,您可以联系我们找货

免费人工找货