3RV1011-0AA15

3RV1011-0AA15

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3RV1011-0AA15 数据手册
Data sheet 3RV1011-0AA15 Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.11...0.16 A Nrelease 2.1 A Screw terminal Standard switching capacity with transverse auxiliary switch 1 NO+1 NC product brand name SIRIUS product designation Circuit breaker design of the product For motor protection product type designation 3RV1 General technical data size of the circuit-breaker S00 size of contactor can be combined company-specific S00 product extension auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 5.5 W ● at AC in hot operating state per pole 1.8 W insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV mechanical service life (operating cycles) ● of the main contacts typical 100 000 ● of auxiliary contacts typical 100 000 electrical endurance (operating cycles) typical 100 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 01/01/2013 SVHC substance name Lead - 7439-92-1 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -20 ... +60 °C ● during storage -50 ... +80 °C ● during transport -50 ... +80 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3 adjustable current response value current of the currentdependent overload release 0.11 ... 0.16 A operating voltage ● rated value 20 ... 690 V ● at AC-3 rated value maximum 690 V ● at AC-3e rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current rated value 0.16 A operational current ● at AC-3 at 400 V rated value 0.16 A ● at AC-3e at 400 V rated value 0.16 A 3RV10110AA15 Page 1/6 5/21/2024 Subject to change without notice © Copyright Siemens operating power ● at AC-3 — at 230 V rated value 0 kW — at 400 V rated value 0.04 kW — at 500 V rated value 0.1 kW — at 690 V rated value 0.1 kW ● at AC-3e — at 230 V rated value 0 kW — at 400 V rated value 0.04 kW — at 500 V rated value 0.1 kW — at 690 V rated value 0.1 kW operating frequency ● at AC-3 maximum 15 1/h ● at AC-3e maximum 15 1/h Auxiliary circuit design of the auxiliary switch transverse number of NC contacts for auxiliary contacts 1 ● note number of NO contacts for auxiliary contacts ● note number of CO contacts for auxiliary contacts 1 1 1 0 operational current of auxiliary contacts at AC-15 ● at 24 V 2A ● at 110 V 2A ● at 120 V 2A ● at 125 V 2A ● at 230 V 0.5 A operational current of auxiliary contacts at DC-13 ● at 24 V 1A ● at 60 V 0.15 A Protective and monitoring functions product function ● ground fault detection No ● phase failure detection Yes trip class CLASS 10 design of the overload release thermal maximum short-circuit current breaking capacity (Icu) ● at AC at 240 V rated value 100 kA ● at AC at 400 V rated value 100 kA ● at AC at 500 V rated value 100 kA ● at AC at 690 V rated value 100 kA operating short-circuit current breaking capacity (Ics) at AC ● at 240 V rated value 100 kA ● at 400 V rated value 100 kA ● at 500 V rated value 100 kA ● at 690 V rated value 100 kA response value current of instantaneous short-circuit trip unit 2.1 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 0.16 A ● at 600 V rated value 0.16 A contact rating of auxiliary contacts according to UL C300 / R300 Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic design of the fuse link ● for short-circuit protection of the auxiliary switch required fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A) design of the fuse link for IT network for short-circuit protection of the main circuit ● at 240 V none required ● at 400 V None required 3RV10110AA15 Page 2/6 5/21/2024 Subject to change without notice © Copyright Siemens ● at 500 V None required ● at 690 V None required Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 height 90 mm width 45 mm depth 75 mm required spacing ● for grounded parts at 400 V — downwards 20 mm — upwards 20 mm — at the side 9 mm ● for live parts at 400 V — downwards 20 mm — upwards 20 mm — at the side 9 mm ● for grounded parts at 500 V — downwards 20 mm — upwards 20 mm — at the side 9 mm ● for live parts at 500 V — downwards 20 mm — upwards 20 mm — at the side 9 mm ● for grounded parts at 690 V — downwards 20 mm — upwards 20 mm — backwards 0 mm — at the side 9 mm — forwards 0 mm ● for live parts at 690 V — downwards 20 mm — upwards 20 mm — backwards 0 mm — at the side 9 mm — forwards 0 mm Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit screw-type terminals arrangement of electrical connectors for main current circuit Top and bottom type of connectable conductor cross-sections ● for main contacts — solid or stranded 2x (0,5 ... 1,5 mm²), 2x (0,75 ... 2,5 mm²), 2x (1 ... 4 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) tightening torque ● for main contacts with screw-type terminals 0.8 ... 1.2 N·m ● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m size of the screwdriver tip Pozidriv size 2 design of the thread of the connection screw ● for main contacts M3 ● of the auxiliary and control contacts M3 Safety related data product function suitable for safety function Yes suitability for use ● safety-related switching on 3RV10110AA15 Page 3/6 No 5/21/2024 Subject to change without notice © Copyright Siemens ● safety-related switching OFF Yes service life maximum 10 a test wear-related service life necessary Yes proportion of dangerous failures ● with low demand rate according to SN 31920 40 % ● with high demand rate according to SN 31920 50 % B10 value with high demand rate according to SN 31920 5 000 failure rate [FIT] with low demand rate according to SN 31920 50 FIT ISO 13849 device type according to ISO 13849-1 3 overdimensioning according to ISO 13849-2 necessary Yes IEC 61508 safety device type according to IEC 61508-2 Type A Electrical Safety protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front Display display version for switching status Rocker switch Approvals Certificates General Product Approval Confirmation General Product Approval For use in hazardous locations KC Test Certificates Type Test Certificates/Test Report Marine / Shipping Special Test Certificate Marine / Shipping other Confirmation Miscellaneous Railway Environment Special Test Certificate Environmental Confirmations Further information Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV1011-0AA15 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV1011-0AA15 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RV1011-0AA15 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV1011-0AA15&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RV1011-0AA15/char 3RV10110AA15 Page 4/6 5/21/2024 Subject to change without notice © Copyright Siemens 13 21 14 22 5/L3 3/L2 1/L1 Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV1011-0AA15&objecttype=14&gridview=view1 -F 3RV10110AA15 Page 5/6 I> 6/T3 I> 4/T2 2/T1 I> 5/21/2024 Subject to change without notice © Copyright Siemens last modified: 3RV10110AA15 Page 6/6 4/12/2024 5/21/2024 Subject to change without notice © Copyright Siemens
3RV1011-0AA15 价格&库存

很抱歉,暂时无法提供与“3RV1011-0AA15”相匹配的价格&库存,您可以联系我们找货

免费人工找货