Data sheet 3RV2011-0KA20 Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.9...1.25 A N-release 16 A Spring-type terminal Standard switching capacity product brand name SIRIUS product designation Circuit breaker design of the product For motor protection product type designation 3RV2 General technical data size of the circuit-breaker S00 size of contactor can be combined company-specific S00, S0 product extension auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 7.25 W ● at AC in hot operating state per pole 2.4 W insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV maximum permissible voltage for safe isolation in networks with grounded star point ● between main and auxiliary circuit 400 V ● between main and auxiliary circuit 400 V shock resistance acc. to IEC 60068-2-27 25g / 11 ms mechanical service life (switching cycles) ● of the main contacts typical 100 000 ● of auxiliary contacts typical 100 000 electrical endurance (switching cycles) typical 100 000 type of protection according to ATEX directive 2014/34/EU Ex II (2) GD certificate of suitability according to ATEX directive 2014/34/EU DMT 02 ATEX F 001 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.10.2009 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -20 ... +60 °C ● ambient temperature during storage -50 ... +80 °C ● ambient temperature during transport -50 ... +80 °C temperature compensation -20 ... +60 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3RV20110KA20 Page 1/2 3 1.19.2021 Subject to change without notice © Copyright Siemens adjustable current response value current of the current-dependent overload release 0.9 ... 1.25 A ● operating voltage rated value 690 V ● operating voltage at AC-3 rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current rated value 1.25 A operational current at AC-3 at 400 V rated value 1.25 A operating power at AC-3 ● at 230 V rated value 180 W ● at 400 V rated value 370 W ● at 500 V rated value 370 W ● at 690 V rated value 750 W operating frequency at AC-3 maximum 15 1/h Auxiliary circuit number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 0 number of CO contacts for auxiliary contacts 0 Protective and monitoring functions product function ● ground fault detection No ● phase failure detection Yes trip class CLASS 10 design of the overload release thermal breaking capacity operating short-circuit current (Ics) at AC ● at 240 V rated value 100 kA ● at 400 V rated value 100 kA ● at 500 V rated value 100 kA ● at 690 V rated value 100 kA breaking capacity maximum short-circuit current (Icu) ● at AC at 240 V rated value 100 kA ● at AC at 400 V rated value 100 kA ● at AC at 500 V rated value 100 kA ● at AC at 690 V rated value 100 kA response value current of instantaneous short-circuit trip unit 16 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 1.25 A ● at 600 V rated value 1.25 A yielded mechanical performance [hp] ● for 3-phase AC motor — at 460/480 V rated value 0.5 hp — at 575/600 V rated value 0.5 hp Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic design of the fuse link for IT network for short-circuit protection of the main circuit ● at 500 V gL/gG 16 A ● at 690 V gL/gG 16 A Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 height 106 mm width 45 mm depth 97 mm required spacing 3RV20110KA20 Page 2/3 1.19.2021 Subject to change without notice © Copyright Siemens ● for grounded parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm ● for live parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm Connections/ Terminals product function removable terminal for auxiliary and control circuit No type of electrical connection ● for main current circuit arrangement of electrical connectors for main current circuit spring-loaded terminals Top and bottom type of connectable conductor cross-sections ● for main contacts — solid or stranded 2x (0,5 ... 4 mm²) — finely stranded with core end processing 2x (0.5 ... 2.5 mm²) — finely stranded without core end processing 2x (0.5 ... 2.5 mm²) ● at AWG cables for main contacts 2x (20 ... 12) design of screwdriver shaft Diameter 3 mm size of the screwdriver tip 3,0 x 0,5 mm Safety related data B10 value ● with high demand rate acc. to SN 31920 5 000 proportion of dangerous failures ● with low demand rate acc. to SN 31920 50 % ● with high demand rate acc. to SN 31920 50 % failure rate [FIT] ● with low demand rate acc. to SN 31920 50 FIT T1 value for proof test interval or service life acc. to IEC 61508 10 y protection class IP on the front acc. to IEC 60529 IP20 touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front display version for switching status Handle Certificates/ approvals General Product Approval 3RV20110KA20 Page 3/4 For use in 1.19.2021 Subject to change without notice © Copyright Siemens hazardous locations KC For use in hazardous locations Declaration of Conformity Test Certificates Miscellaneous Type Test Certificates/Test Report Marine / Shipping Special Test Certificate Marine / Shipping other Confirmation Railway Vibration and Shock Confirmation Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2011-0KA20 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2011-0KA20 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-0KA20 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2011-0KA20&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-0KA20/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV2011-0KA20&objecttype=14&gridview=view1 3RV20110KA20 Page 4/5 1.19.2021 Subject to change without notice © Copyright Siemens 3RV20110KA20 Page 5/6 1.19.2021 Subject to change without notice © Copyright Siemens 3RV20110KA20 Page 6/7 1.19.2021 Subject to change without notice © Copyright Siemens last modified: 3RV20110KA20 Page 7/7 12/15/2020 1.19.2021 Subject to change without notice © Copyright Siemens
3RV20110KA20
物料型号:3RV2011-0KA20 器件简介:西门子SIRIUS品牌下的电机保护用断路器,型号为3RV2,尺寸为S00,具有辅助开关,标准切换容量。

引脚分配:主电路为3极,辅助电路没有NC、NO、CO接触点。

参数特性:额定操作电压690V,操作频率50-60Hz,额定操作电流1.25A,额定操作功率在不同电压下分别为230V-180W、400V-370W、500V-370W、690V-750W。

功能详解:具有过载保护、短路保护功能,过载保护为热磁式,短路保护为电磁式,瞬时短路脱扣单元的响应电流为16A。

应用信息:适用于电机保护,具有相失败检测功能,不具有接地故障检测功能,适用于ATEX指令2014/34/EU下的ExlI(2)GD型保护。

封装信息:可安装在35mm标准安装导轨上,高度106mm,宽度45mm,深度97mm,需要的间距因电压不同而异。


以上信息摘自西门子3RV2011-0KA20断路器的数据手册。