0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RV20110KA40

3RV20110KA40

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    MSP S00 0.9-1.25A RING LUG

  • 数据手册
  • 价格&库存
3RV20110KA40 数据手册
Data sheet 3RV2011-0KA40 Circuit breaker size S00 for motor protection, CLASS 10 A-release 0.9...1.25 A N-release 16 A ring cable lug connection Standard switching capacity product brand name SIRIUS product designation Circuit breaker design of the product For motor protection product type designation 3RV2 General technical data size of the circuit-breaker S00 size of contactor can be combined company-specific S00, S0 product extension auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 7.25 W ● at AC in hot operating state per pole 2.4 W insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV maximum permissible voltage for safe isolation in networks with grounded star point ● between main and auxiliary circuit 400 V ● between main and auxiliary circuit 400 V shock resistance acc. to IEC 60068-2-27 25g / 11 ms mechanical service life (switching cycles) ● of the main contacts typical 100 000 ● of auxiliary contacts typical 100 000 electrical endurance (switching cycles) typical 100 000 type of protection according to ATEX directive 2014/34/EU Ex II (2) GD certificate of suitability according to ATEX directive 2014/34/EU DMT 02 ATEX F 001 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 01.10.2009 00:00:00 Ambient conditions installation altitude at height above sea level maximum 2 000 m ● ambient temperature during operation -20 ... +60 °C ● ambient temperature during storage -50 ... +80 °C ● ambient temperature during transport -50 ... +80 °C temperature compensation -20 ... +60 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3RV20110KA40 Page 1/2 3 1.21.2021 Subject to change without notice © Copyright Siemens adjustable current response value current of the current-dependent overload release 0.9 ... 1.25 A ● operating voltage rated value 690 V ● operating voltage at AC-3 rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current rated value 1.25 A operational current at AC-3 at 400 V rated value 1.25 A operating power at AC-3 ● at 230 V rated value 180 W ● at 400 V rated value 370 W ● at 500 V rated value 370 W ● at 690 V rated value 750 W operating frequency at AC-3 maximum 15 1/h Auxiliary circuit number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 0 number of CO contacts for auxiliary contacts 0 Protective and monitoring functions product function ● ground fault detection No ● phase failure detection Yes trip class CLASS 10 design of the overload release thermal breaking capacity operating short-circuit current (Ics) at AC ● at 240 V rated value 100 kA ● at 400 V rated value 100 kA ● at 500 V rated value 100 kA ● at 690 V rated value 100 kA breaking capacity maximum short-circuit current (Icu) ● at AC at 240 V rated value 100 kA ● at AC at 400 V rated value 100 kA ● at AC at 500 V rated value 100 kA ● at AC at 690 V rated value 100 kA response value current of instantaneous short-circuit trip unit 16 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 1.25 A ● at 600 V rated value 1.25 A yielded mechanical performance [hp] ● for 3-phase AC motor — at 460/480 V rated value 0.5 hp — at 575/600 V rated value 0.5 hp Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic design of the fuse link for IT network for short-circuit protection of the main circuit ● at 500 V gL/gG 16 A ● at 690 V gL/gG 16 A Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715 height 97 mm width 45 mm depth 97 mm required spacing 3RV20110KA40 Page 2/3 1.21.2021 Subject to change without notice © Copyright Siemens ● for grounded parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm ● for live parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm Connections/ Terminals product function removable terminal for auxiliary and control circuit No type of electrical connection ● for main current circuit Ring cable lug connection ● for auxiliary and control circuit ring cable connection arrangement of electrical connectors for main current circuit Top and bottom ● tightening torque — for main contacts for ring cable lug 0.8 ... 1.2 N·m — for auxiliary contacts for ring cable lug 1.2 ... 0.8 N·m outer diameter of the usable ring cable lug maximum 7.5 mm design of screwdriver shaft Diameter 5 to 6 mm size of the screwdriver tip Size 2 and Pozidriv 2 design of the thread of the connection screw ● for main contacts M3 ● of the auxiliary and control contacts M3 Safety related data B10 value ● with high demand rate acc. to SN 31920 5 000 proportion of dangerous failures ● with low demand rate acc. to SN 31920 50 % ● with high demand rate acc. to SN 31920 50 % failure rate [FIT] ● with low demand rate acc. to SN 31920 50 FIT T1 value for proof test interval or service life acc. to IEC 61508 10 y protection class IP on the front acc. to IEC 60529 IP00 display version for switching status Handle Certificates/ approvals 3RV20110KA40 Page 3/4 1.21.2021 Subject to change without notice © Copyright Siemens For use in hazardous locations General Product Approval KC For use in hazardous locations Declaration of Conformity Test Certificates Miscellaneous Special Test Certificate Marine / Shipping Type Test Certificates/Test Report Marine / Shipping other Confirmation Railway Confirmation Vibration and Shock Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2011-0KA40 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2011-0KA40 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-0KA40 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2011-0KA40&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RV2011-0KA40/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV2011-0KA40&objecttype=14&gridview=view1 3RV20110KA40 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens 3RV20110KA40 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens 3RV20110KA40 Page 6/7 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 3RV20110KA40 Page 7/7 12/23/2020 1.21.2021 Subject to change without notice © Copyright Siemens
3RV20110KA40 价格&库存

很抱歉,暂时无法提供与“3RV20110KA40”相匹配的价格&库存,您可以联系我们找货

免费人工找货