3RV20214DA20

3RV20214DA20

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    Thermal Mag Ckt Breaker, 3P, 25A, 690V Rohs Compliant: Yes

  • 数据手册
  • 价格&库存
3RV20214DA20 数据手册
Data sheet 3RV2021-4DA20 Circuit breaker size S0 for motor protection, CLASS 10 A-release 18...25 A Nrelease 325 A Spring-type terminal Standard switching capacity product brand name SIRIUS product designation Circuit breaker design of the product For motor protection product type designation 3RV2 General technical data size of the circuit-breaker S0 size of contactor can be combined company-specific S00, S0 product extension auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 10.5 W ● at AC in hot operating state per pole 3.5 W insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV shock resistance according to IEC 60068-2-27 25g / 11 ms mechanical service life (operating cycles) ● of the main contacts typical 100 000 ● of auxiliary contacts typical 100 000 electrical endurance (operating cycles) typical 100 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 10/01/2009 SVHC substance name Lead - 7439-92-1 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -20 ... +60 °C ● during storage -50 ... +80 °C ● during transport -50 ... +80 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3 adjustable current response value current of the currentdependent overload release 18 ... 25 A operating voltage ● rated value 20 ... 690 V ● at AC-3 rated value maximum 690 V ● at AC-3e rated value maximum 690 V operating frequency rated value 3RV20214DA20 Page 1/6 50 ... 60 Hz 5/23/2024 Subject to change without notice © Copyright Siemens operational current rated value 25 A operational current ● at AC-3 at 400 V rated value 25 A ● at AC-3e at 400 V rated value 25 A operating power ● at AC-3 — at 230 V rated value 5.5 kW — at 400 V rated value 11 kW — at 500 V rated value 15 kW — at 690 V rated value 22 kW ● at AC-3e — at 230 V rated value 5.5 kW — at 400 V rated value 11 kW — at 500 V rated value 15 kW — at 690 V rated value 22 kW operating frequency ● at AC-3 maximum 15 1/h ● at AC-3e maximum 15 1/h Auxiliary circuit number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 0 number of CO contacts for auxiliary contacts 0 Protective and monitoring functions product function ● ground fault detection No ● phase failure detection Yes trip class CLASS 10 design of the overload release thermal maximum short-circuit current breaking capacity (Icu) ● at AC at 240 V rated value 100 kA ● at AC at 400 V rated value 55 kA ● at AC at 500 V rated value 10 kA ● at AC at 690 V rated value 4 kA operating short-circuit current breaking capacity (Ics) at AC ● at 240 V rated value 100 kA ● at 400 V rated value 25 kA ● at 500 V rated value 5 kA ● at 690 V rated value 2 kA response value current of instantaneous short-circuit trip unit 325 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 25 A ● at 600 V rated value 25 A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 2 hp — at 230 V rated value 3 hp ● for 3-phase AC motor — at 200/208 V rated value 5 hp — at 220/230 V rated value 7.5 hp — at 460/480 V rated value 15 hp Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic design of the fuse link for IT network for short-circuit protection of the main circuit ● at 400 V gL/gG 63 A ● at 500 V gL/gG 50 A ● at 690 V gL/gG 50 A Installation/ mounting/ dimensions mounting position 3RV20214DA20 Page 2/6 any 5/23/2024 Subject to change without notice © Copyright Siemens fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 height 119 mm width 45 mm depth 97 mm required spacing ● with side-by-side mounting at the side 0 mm ● for grounded parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 400 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for live parts at 500 V — downwards 30 mm — upwards 30 mm — at the side 9 mm ● for grounded parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm ● for live parts at 690 V — downwards 50 mm — upwards 50 mm — backwards 0 mm — at the side 30 mm — forwards 0 mm Connections/ Terminals type of electrical connection ● for main current circuit arrangement of electrical connectors for main current circuit spring-loaded terminals Top and bottom type of connectable conductor cross-sections ● for main contacts — solid or stranded 2x (1 ... 10 mm²) — finely stranded with core end processing 2x (1 ... 6 mm²) — finely stranded without core end processing 2x (1 ... 6 mm²) ● for AWG cables for main contacts 2x (18 ... 8) design of screwdriver shaft Diameter 3 mm size of the screwdriver tip 3,0 x 0,5 mm Safety related data product function suitable for safety function Yes suitability for use ● safety-related switching on No ● safety-related switching OFF Yes service life maximum 10 a test wear-related service life necessary Yes proportion of dangerous failures ● with low demand rate according to SN 31920 40 % ● with high demand rate according to SN 31920 50 % B10 value with high demand rate according to SN 31920 5 000 failure rate [FIT] with low demand rate according to SN 31920 50 FIT ISO 13849 3RV20214DA20 Page 3/6 5/23/2024 Subject to change without notice © Copyright Siemens device type according to ISO 13849-1 3 overdimensioning according to ISO 13849-2 necessary Yes IEC 61508 safety device type according to IEC 61508-2 Type A T1 value ● for proof test interval or service life according to IEC 61508 10 a Electrical Safety protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front Display display version for switching status Handle Approvals Certificates General Product Approval Confirmation General Product Approval For use in hazardous locations KC Test Certificates Special Test Certificate Marine / Shipping Type Test Certificates/Test Report Marine / Shipping other Miscellaneous other Confirmation Railway Environment Special Test Certificate Confirmation Environment Environmental Confirmations Further information Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2021-4DA20 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2021-4DA20 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-4DA20 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2021-4DA20&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RV2021-4DA20/char 3RV20214DA20 Page 4/6 5/23/2024 Subject to change without notice © Copyright Siemens Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV2021-4DA20&objecttype=14&gridview=view1 3RV20214DA20 Page 5/6 5/23/2024 Subject to change without notice © Copyright Siemens 5/L3 3/L2 1/L1 -F last modified: 3RV20214DA20 Page 6/6 I> 6/T3 I> 4/T2 2/T1 I> 4/12/2024 5/23/2024 Subject to change without notice © Copyright Siemens
3RV20214DA20 价格&库存

很抱歉,暂时无法提供与“3RV20214DA20”相匹配的价格&库存,您可以联系我们找货

免费人工找货