0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RV2032-4RA15

3RV2032-4RA15

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
3RV2032-4RA15 数据手册
Data sheet 3RV2032-4RA15 Circuit breaker size S2 for motor protection, CLASS 10 A-release 70...80 A Nrelease 1040 A screw terminal increased switching capacity with transverse auxiliary switches 1 NO+1 NC product brand name SIRIUS product designation Circuit breaker design of the product For motor protection product type designation 3RV2 General technical data size of the circuit-breaker S2 size of contactor can be combined company-specific S2 product extension auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 29.5 W ● at AC in hot operating state per pole 9.8 W insulation voltage with degree of pollution 3 at AC rated value 690 V surge voltage resistance rated value 6 kV shock resistance according to IEC 60068-2-27 25g / 11 ms Sinus mechanical service life (operating cycles) ● of the main contacts typical 20 000 ● of auxiliary contacts typical 20 000 electrical endurance (operating cycles) typical 20 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 03/01/2017 SVHC substance name Lead - 7439-92-1 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -20 ... +60 °C ● during storage -50 ... +80 °C ● during transport -50 ... +80 °C relative humidity during operation 10 ... 95 % Main circuit number of poles for main current circuit 3 adjustable current response value current of the currentdependent overload release 70 ... 80 A operating voltage ● rated value 20 ... 690 V ● at AC-3 rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current rated value 80 A 3RV20324RA15 Page 1/6 4/19/2024 Subject to change without notice © Copyright Siemens operational current ● at AC-3 at 400 V rated value 80 A operating power ● at AC-3 — at 230 V rated value 22 kW — at 400 V rated value 37 kW — at 500 V rated value 55 kW — at 690 V rated value 75 kW operating frequency ● at AC-3 maximum 15 1/h Auxiliary circuit design of the auxiliary switch transverse number of NC contacts for auxiliary contacts 1 number of NO contacts for auxiliary contacts 1 operational current of auxiliary contacts at AC-15 ● at 24 V 2A ● at 230 V 0.5 A operational current of auxiliary contacts at DC-13 ● at 24 V 1A ● at 60 V 0.15 A ● at 110 V 0A ● at 125 V 0A ● at 220 V 0A Protective and monitoring functions product function ● ground fault detection No ● phase failure detection Yes trip class CLASS 10 design of the overload release thermal maximum short-circuit current breaking capacity (Icu) ● at AC at 240 V rated value 100 kA ● at AC at 400 V rated value 100 kA ● at AC at 500 V rated value 10 kA ● at AC at 690 V rated value 6 kA operating short-circuit current breaking capacity (Ics) at AC ● at 240 V rated value 100 kA ● at 400 V rated value 50 kA ● at 500 V rated value 8 kA ● at 690 V rated value 4 kA response value current of instantaneous short-circuit trip unit 1 040 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 77 A ● at 600 V rated value 77 A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 7.5 hp — at 230 V rated value 15 hp ● for 3-phase AC motor — at 200/208 V rated value 25 hp — at 220/230 V rated value 30 hp — at 460/480 V rated value 60 hp — at 575/600 V rated value 75 hp contact rating of auxiliary contacts according to UL C300 / R300 Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic design of the fuse link ● for short-circuit protection of the auxiliary switch required fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A) design of the fuse link for IT network for short-circuit protection of the main circuit 3RV20324RA15 Page 2/6 4/19/2024 Subject to change without notice © Copyright Siemens ● at 240 V none required ● at 400 V 160 ● at 500 V 125 ● at 690 V 100 Installation/ mounting/ dimensions mounting position any fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 height 140 mm width 55 mm depth 149 mm required spacing ● with side-by-side mounting at the side 0 mm ● for grounded parts at 400 V — downwards 50 mm — upwards 50 mm — at the side 10 mm ● for live parts at 400 V — downwards 50 mm — upwards 50 mm — at the side 10 mm ● for grounded parts at 500 V — downwards 50 mm — upwards 50 mm — at the side 10 mm ● for live parts at 500 V — downwards 50 mm — upwards 50 mm — at the side 10 mm ● for grounded parts at 690 V — downwards 50 mm — upwards 50 mm — at the side 10 mm ● for live parts at 690 V — downwards 50 mm — upwards 50 mm — at the side 10 mm Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit screw-type terminals arrangement of electrical connectors for main current circuit Top and bottom type of connectable conductor cross-sections ● for main contacts — solid or stranded 2x (1 ... 35 mm²), 1x (1 ... 50 mm²) — finely stranded with core end processing 2x (1 ... 25 mm²), 1x (1 ... 35 mm²) ● for AWG cables for main contacts 2x (18 ... 2), 1x (18 ... 1) type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) — finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) ● for AWG cables for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14) tightening torque ● for main contacts with screw-type terminals 3 ... 4.5 N·m ● for auxiliary contacts with screw-type terminals 0.8 ... 1.2 N·m design of screwdriver shaft Diameter 5 to 6 mm size of the screwdriver tip Pozidriv size 2 design of the thread of the connection screw ● for main contacts M6 ● of the auxiliary and control contacts M3 Safety related data 3RV20324RA15 Page 3/6 4/19/2024 Subject to change without notice © Copyright Siemens product function suitable for safety function Yes suitability for use ● safety-related switching on No ● safety-related switching OFF Yes service life maximum 10 a test wear-related service life necessary Yes proportion of dangerous failures ● with low demand rate according to SN 31920 40 % ● with high demand rate according to SN 31920 50 % B10 value with high demand rate according to SN 31920 5 000 failure rate [FIT] with low demand rate according to SN 31920 50 FIT ISO 13849 device type according to ISO 13849-1 3 overdimensioning according to ISO 13849-2 necessary Yes IEC 61508 safety device type according to IEC 61508-2 Type A T1 value ● for proof test interval or service life according to IEC 61508 10 a Electrical Safety protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front Display display version for switching status Handle Approvals Certificates General Product Approval Confirmation General Product Approval For use in hazardous locations KC Test Certificates Special Test Certificate Marine / Shipping Type Test Certificates/Test Report Marine / Shipping other Miscellaneous other Confirmation Railway Environment Special Test Certificate Confirmation Environment Environmental Confirmations 3RV20324RA15 Page 4/6 4/19/2024 Subject to change without notice © Copyright Siemens Further information Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RV2032-4RA15 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RV2032-4RA15 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RV2032-4RA15 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RV2032-4RA15&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RV2032-4RA15/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RV2032-4RA15&objecttype=14&gridview=view1 3RV20324RA15 Page 5/6 4/19/2024 Subject to change without notice © Copyright Siemens 13 21 14 22 5/L3 3/L2 1/L1 -F last modified: 3RV20324RA15 Page 6/6 I> 6/T3 I> 4/T2 2/T1 I> 4/12/2024 4/19/2024 Subject to change without notice © Copyright Siemens
3RV2032-4RA15 价格&库存

很抱歉,暂时无法提供与“3RV2032-4RA15”相匹配的价格&库存,您可以联系我们找货

免费人工找货