Data sheet 3RW3036-2BB14 SIRIUS soft starter S2 45 A, 22 kW/400 V, 40 °C 200-480 V AC, 110-230 V AC/DC spring-type terminals General technical data product brand name SIRIUS product feature ● integrated bypass contact system Yes ● thyristors Yes product function ● intrinsic device protection No ● motor overload protection No ● evaluation of thermistor motor protection No ● external reset No ● adjustable current limitation No ● inside-delta circuit No product component motor brake output insulation voltage rated value No V 600 degree of pollution 3, acc. to IEC 60947-4-2 reference code according to EN 61346-2 Q reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 G Power Electronics product designation Soft starter operational current ● at 40 °C rated value A 45 ● at 50 °C rated value A 42 ● at 60 °C rated value A 39 kW 11 yielded mechanical performance for 3-phase motors ● at 230 V — at standard circuit at 40 °C rated value ● at 400 V kW 22 yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value — at standard circuit at 40 °C rated value hp 10 operating frequency rated value Hz 50 ... 60 relative negative tolerance of the operating frequency % -10 relative positive tolerance of the operating frequency % 10 operating voltage at standard circuit rated value V 200 ... 480 relative negative tolerance of the operating voltage at standard circuit % -15 relative positive tolerance of the operating voltage at standard circuit % 10 minimum load [%] % 10 continuous operating current [% of Ie] at 40 °C % 115 3RW30362BB14 Page 1/5 5/16/2024 Subject to change without notice © Copyright Siemens power loss [W] at operational current at 40 °C during operation typical W 6 Control circuit/ Control type of voltage of the control supply voltage AC/DC control supply voltage frequency 1 rated value Hz 50 control supply voltage frequency 2 rated value Hz 60 relative negative tolerance of the control supply voltage frequency % -10 relative positive tolerance of the control supply voltage frequency % 10 control supply voltage 1 at AC at 50 Hz V 110 ... 230 control supply voltage 1 at AC at 60 Hz V 110 ... 230 relative negative tolerance of the control supply voltage at AC at 50 Hz % -10 relative positive tolerance of the control supply voltage at AC at 50 Hz % 10 relative negative tolerance of the control supply voltage at AC at 60 Hz % -10 relative positive tolerance of the control supply voltage at AC at 60 Hz % 10 control supply voltage 1 at DC V 110 ... 230 relative negative tolerance of the control supply voltage at DC % -10 relative positive tolerance of the control supply voltage at DC % 10 display version for fault signal red Mechanical data size of engine control device S2 width mm 55 height mm 160 depth mm 170 fastening method screw and snap-on mounting mounting position With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back required spacing with side-by-side mounting ● upwards mm 60 ● at the side mm 30 ● downwards mm 40 wire length maximum m 300 number of poles for main current circuit 3 Connections/ Terminals type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit spring-loaded terminals number of NC contacts for auxiliary contacts 0 number of NO contacts for auxiliary contacts 1 number of CO contacts for auxiliary contacts 0 type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point ● solid 2x (1.5 ... 16 mm²) ● finely stranded with core end processing 1.5 ... 25 mm² ● stranded 1.5 ... 35 mm² type of connectable conductor cross-sections for main contacts for box terminal using the back clamping point ● solid 2x (1.5 ... 16 mm²) ● finely stranded with core end processing 1.5 ... 25 mm² ● stranded 1.5 ... 35 mm² type of connectable conductor cross-sections for main contacts for box terminal using both clamping points ● solid 2x (1.5 ... 16 mm²) ● finely stranded with core end processing 2x (1.5 ... 16 mm²) ● stranded 2x (1.5 ... 25 mm²) type of connectable conductor cross-sections for AWG cables for main contacts for box terminal ● using the back clamping point 3RW30362BB14 Page 2/5 16 ... 2 5/16/2024 Subject to change without notice © Copyright Siemens ● using the front clamping point 18 ... 2 ● using both clamping points 2x (16 ... 2) type of connectable conductor cross-sections for auxiliary contacts ● solid 2x (0.25 ... 2.5 mm²) ● finely stranded with core end processing 2x (0.25 ... 1.5 mm²) type of connectable conductor cross-sections for AWG cables ● for auxiliary contacts 2x (24 ... 14) Ambient conditions installation altitude at height above sea level m 5 000 environmental category ● during transport according to IEC 60721 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) ● during storage according to IEC 60721 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 ● during operation according to IEC 60721 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 ambient temperature ● during operation °C -25 ... +60 ● during storage °C -40 ... +80 °C 40 derating temperature protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front UL/CSA ratings yielded mechanical performance [hp] for 3-phase AC motor ● at 220/230 V — at standard circuit at 50 °C rated value hp 15 hp 30 ● at 460/480 V — at standard circuit at 50 °C rated value contact rating of auxiliary contacts according to UL B300 / R300 Approvals Certificates General Product Approval Confirmation General Product Approval EMV Test Certificates KC other Confirmation Type Test Certificates/Test Report Railway Special Test Certificate other Special Test Certificate Miscellaneous Environment Confirmation Environmental Confirmations Further information Simulation Tool for Soft Starters (STS) https://support.industry.siemens.com/cs/ww/en/view/101494917 Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW3036-2BB14 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW3036-2BB14 3RW30362BB14 Page 3/5 5/16/2024 Subject to change without notice © Copyright Siemens 3RW30362BB14 Page 4/5 5/16/2024 13 NO A2 ON 14 5/L3 6/T3 -Q IN 1 3/L2 4/T2 A1 1/L1 2/T1 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RW3036-2BB14 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW3036-2BB14&lang=en Subject to change without notice © Copyright Siemens last modified: 3RW30362BB14 Page 5/5 3/11/2024 5/16/2024 Subject to change without notice © Copyright Siemens
3RW3036-2BB14 价格&库存

很抱歉,暂时无法提供与“3RW3036-2BB14”相匹配的价格&库存,您可以联系我们找货

免费人工找货