Data sheet
3RW5074-2TB15
SIRIUS soft starter 200-600 V 315 A, 110-250 V AC Spring-loaded
terminals Thermistor input
product brand name
SIRIUS
product category
Hybrid switching devices
product designation
Soft starter
product type designation
3RW50
manufacturer's article number
● of standard HMI module usable
3RW5980-0HS01
● of high feature HMI module usable
3RW5980-0HF00
● of communication module PROFINET standard
usable
3RW5980-0CS00
● of communication module PROFIBUS usable
3RW5980-0CP00
● of communication module Modbus TCP usable
3RW5980-0CT00
● of communication module Modbus RTU usable
3RW5980-0CR00
● of communication module Ethernet/IP
3RW5980-0CE00
● of circuit breaker usable at 400 V
3VA2440-7MN32-0AA0; Type of assignment 1, Iq = 65 kA
● of circuit breaker usable at 500 V
3VA2440-7MN32-0AA0; Type of assignment 1, Iq = 65 kA
● of the gG fuse usable up to 690 V
2x3NA3365-6; Type of coordination 1, Iq = 65 kA
● of full range R fuse link for semiconductor protection
usable up to 690 V
3NE1 333-2; Type of coordination 2, Iq = 65 kA
● of back-up R fuse link for semiconductor protection
usable up to 690 V
3NE3 335; Type of coordination 2, Iq = 65 kA
● of line contactor usable up to 480 V
3RT1075
● of line contactor usable up to 690 V
3RT1075
General technical data
starting voltage [%]
30 ... 100 %
stopping voltage [%]
50 ... 50 %
start-up ramp time of soft starter
0 ... 20 s
ramp-down time of soft starter
0 ... 20 s
current limiting value [%] adjustable
130 ... 700 %
accuracy class acc. to IEC 61557-12
5%
certificate of suitability
● CE marking
Yes
● UL approval
Yes
● CSA approval
Yes
product component is supported
● HMI-Standard
Yes
● HMI-High Feature
Yes
product feature integrated bypass contact system
Yes
number of controlled phases
2
3RW50742TB15
Page 1/2
12.21.2020
Subject to change without notice
© Copyright Siemens
trip class
CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
buffering time in the event of power failure
● for main current circuit
100 ms
● for control circuit
100 ms
insulation voltage rated value
600 V
degree of pollution
3, acc. to IEC 60947-4-2
impulse voltage rated value
6 kV
blocking voltage of the thyristor maximum
1 600 V
service factor
1
reference code acc. to IEC 81346-2
Q
product function
● ramp-up (soft starting)
Yes
● ramp-down (soft stop)
Yes
● Soft Torque
Yes
● adjustable current limitation
Yes
● pump ramp down
Yes
● intrinsic device protection
Yes
● motor overload protection
Yes; Full motor protection (thermistor motor protection and electronic
motor overload protection)
● evaluation of thermistor motor protection
Yes; Type A PTC or Klixon / Thermoclick
● auto-RESET
Yes
● manual RESET
Yes
● remote reset
Yes; By turning off the control supply voltage
● communication function
Yes
● operating measured value display
Yes; Only in conjunction with special accessories
● error logbook
Yes; Only in conjunction with special accessories
● via software parameterizable
No
● via software configurable
Yes
● PROFIenergy
Yes; in connection with the PROFINET Standard communication
module
● voltage ramp
Yes
● torque control
No
● analog output
No
Power Electronics
operational current
● at 40 °C rated value
315 A
● at 50 °C rated value
279 A
● at 60 °C rated value
255 A
operating voltage
● rated value
200 ... 600 V
relative negative tolerance of the operating voltage
-15 %
relative positive tolerance of the operating voltage
10 %
operating power for 3-phase motors
● at 230 V at 40 °C rated value
90 kW
● at 400 V at 40 °C rated value
160 kW
● at 500 V at 40 °C rated value
200 kW
Operating frequency 1 rated value
50 Hz
Operating frequency 2 rated value
60 Hz
relative negative tolerance of the operating frequency
-10 %
relative positive tolerance of the operating frequency
10 %
adjustable motor current
● at rotary coding switch on switch position 1
135 A
● at rotary coding switch on switch position 2
147 A
● at rotary coding switch on switch position 3
159 A
● at rotary coding switch on switch position 4
171 A
● at rotary coding switch on switch position 5
183 A
● at rotary coding switch on switch position 6
195 A
● at rotary coding switch on switch position 7
207 A
● at rotary coding switch on switch position 8
219 A
3RW50742TB15
Page 2/3
12.21.2020
Subject to change without notice
© Copyright Siemens
● at rotary coding switch on switch position 9
231 A
● at rotary coding switch on switch position 10
243 A
● at rotary coding switch on switch position 11
255 A
● at rotary coding switch on switch position 12
267 A
● at rotary coding switch on switch position 13
279 A
● at rotary coding switch on switch position 14
291 A
● at rotary coding switch on switch position 15
303 A
● at rotary coding switch on switch position 16
315 A
● minimum
135 A
minimum load [%]
15 %; Relative to smallest settable Ie
power loss [W] for rated value of the current at AC
● at 40 °C after startup
36 W
● at 50 °C after startup
29 W
● at 60 °C after startup
24 W
power loss [W] at AC at current limitation 350 %
● at 40 °C during startup
3 368 W
● at 50 °C during startup
2 805 W
● at 60 °C during startup
2 455 W
type of the motor protection
Electronic, tripping in the event of thermal overload of the motor
Control circuit/ Control
type of voltage of the control supply voltage
AC
● control supply voltage at AC at 50 Hz
110 ... 250 V
● control supply voltage at AC at 60 Hz
110 ... 250 V
relative negative tolerance of the control supply
voltage at AC at 50 Hz
-15 %
relative positive tolerance of the control supply
voltage at AC at 50 Hz
10 %
relative negative tolerance of the control supply
voltage at AC at 60 Hz
-15 %
relative positive tolerance of the control supply
voltage at AC at 60 Hz
10 %
control supply voltage frequency
50 ... 60 Hz
relative negative tolerance of the control supply
voltage frequency
-10 %
relative positive tolerance of the control supply
voltage frequency
10 %
control supply current in standby mode rated value
30 mA
holding current in bypass operation rated value
105 mA
locked-rotor current at close of bypass contact
maximum
2.2 A
inrush current peak at application of control supply voltage
maximum
12.2 A
duration of inrush current peak at application of control
supply voltage
2.2 ms
design of the overvoltage protection
Varistor
design of short-circuit protection for control circuit
4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature
circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is
not part of scope of supply
Inputs/ Outputs
number of digital inputs
1
number of inputs for thermistor connection
1; Type A PTC or Klixon / Thermoclick
number of digital outputs
3
● not parameterizable
2
digital output version
2 normally-open contacts (NO) / 1 changeover contact (CO)
number of analog outputs
0
Installation/ mounting/ dimensions
mounting position
with vertical mounting surface +/-90° rotatable, with vertical mounting
surface +/- 22.5° tiltable to the front and back
fastening method
screw fixing
height
230 mm
width
160 mm
3RW50742TB15
Page 3/4
12.21.2020
Subject to change without notice
© Copyright Siemens
depth
282 mm
required spacing with side-by-side mounting
● forwards
10 mm
● backwards
0 mm
● upwards
100 mm
● downwards
75 mm
● at the side
5 mm
weight without packaging
7.3 kg
Connections/ Terminals
type of electrical connection
● for main current circuit
busbar connection
● for control circuit
spring-loaded terminals
width of connection bar maximum
45 mm
wire length for thermistor connection
● with conductor cross-section = 0.5 mm² maximum
50 m
● with conductor cross-section = 1.5 mm² maximum
150 m
● with conductor cross-section = 2.5 mm² maximum
250 m
type of connectable conductor cross-sections
● for main contacts for box terminal using the front
clamping point solid
95 ... 300 mm²
● for main contacts for box terminal using the front
clamping point finely stranded with core end
processing
70 ... 240 mm²
● for main contacts for box terminal using the front
clamping point finely stranded without core end
processing
70 ... 240 mm²
● for main contacts for box terminal using the front
clamping point stranded
95 ... 300 mm²
● at AWG cables for main contacts for box terminal
using the front clamping point
3/0 ... 600 kcmil
● for main contacts for box terminal using the back
clamping point solid
120 ... 240 mm²
● at AWG cables for main contacts for box terminal
using the back clamping point
250 ... 500 kcmil
● for main contacts for box terminal using both
clamping points solid
min. 2x 70 mm², max. 2x 240 mm²
● for main contacts for box terminal using both
clamping points finely stranded with core end
processing
min. 2x 50 mm², max. 2x 185 mm²
● for main contacts for box terminal using both
clamping points finely stranded without core end
processing
min. 2x 50 mm², max. 2x 185 mm²
● for main contacts for box terminal using both
clamping points stranded
min. 2x 70 mm², max. 2x 240 mm²
● for main contacts for box terminal using the back
clamping point finely stranded with core end
processing
120 ... 185 mm²
● for main contacts for box terminal using the back
clamping point finely stranded without core end
processing
120 ... 185 mm²
● for main contacts for box terminal using the back
clamping point stranded
120 ... 240 mm²
type of connectable conductor cross-sections
● at AWG cables for main current circuit solid
2/0 ... 500 kcmil
● for DIN cable lug for main contacts stranded
50 ... 240 mm²
● for DIN cable lug for main contacts finely stranded
70 ... 240 mm²
type of connectable conductor cross-sections
● for control circuit solid
2x (0.25 ... 1.5 mm²)
● for control circuit finely stranded with core end
processing
2x (0.25 ... 1.5 mm²)
● at AWG cables for control circuit solid
2x (24 ... 16)
● at AWG cables for control circuit finely stranded with
core end processing
2x (24 ... 16)
3RW50742TB15
Page 4/5
12.21.2020
Subject to change without notice
© Copyright Siemens
wire length
● between soft starter and motor maximum
800 m
● at the digital inputs at AC maximum
1 000 m
tightening torque
● for main contacts with screw-type terminals
14 ... 24 N·m
● for auxiliary and control contacts with screw-type
terminals
0.8 ... 1.2 N·m
tightening torque [lbf·in]
● for main contacts with screw-type terminals
124 ... 210 lbf·in
● for auxiliary and control contacts with screw-type
terminals
7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum
5 000 m; Derating as of 1000 m, see manual
● ambient temperature during operation
-25 ... +60 °C; Please observe derating at temperatures of 40 °C or
above
● ambient temperature during storage and transport
-40 ... +80 °C
environmental category
● during operation acc. to IEC 60721
3K6 (no ice formation, only occasional condensation), 3C3 (no salt
mist), 3S2 (sand must not get into the devices), 3M6
● during storage acc. to IEC 60721
1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must
not get inside the devices), 1M4
● during transport acc. to IEC 60721
2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
EMC emitted interference
acc. to IEC 60947-4-2: Class A
Communication/ Protocol
communication module is supported
● PROFINET standard
Yes
● EtherNet/IP
Yes
● Modbus RTU
Yes
● Modbus TCP
Yes
● PROFIBUS
Yes
UL/CSA ratings
manufacturer's article number
● of circuit breaker
— usable for High Faults at 460/480 V according
to UL
Siemens type: 3VA54, max. 600 A; Iq max = 65 kA
● of the fuse
— usable for Standard Faults up to 575/600 V
according to UL
Type: Class L, max. 1000 A; Iq = 18 kA
— usable for High Faults up to 575/600 V
according to UL
Type: Class L, max. 1000 A; Iq = 100 kA
operating power [hp] for 3-phase motors
● at 200/208 V at 50 °C rated value
75 hp
● at 220/230 V at 50 °C rated value
100 hp
● at 460/480 V at 50 °C rated value
200 hp
● at 575/600 V at 50 °C rated value
250 hp
Safety related data
protection class IP on the front acc. to IEC 60529
IP00; IP20 with cover
touch protection on the front acc. to IEC 60529
finger-safe, for vertical contact from the front with cover
ATEX
certificate of suitability
● ATEX
Yes
● IECEx
Yes
hardware fault tolerance acc. to IEC 61508 relating to
ATEX
0
PFDavg with low demand rate acc. to IEC 61508
relating to ATEX
0.09
PFHD with high demand rate acc. to EN 62061 relating
to ATEX
0.000009 1/h
Safety Integrity Level (SIL) acc. to IEC 61508 relating
to ATEX
SIL1
3RW50742TB15
Page 5/6
12.21.2020
Subject to change without notice
© Copyright Siemens
T1 value for proof test interval or service life acc. to
IEC 61508 relating to ATEX
3y
Certificates/ approvals
General Product Approval
Declaration of Conformity
Miscellaneous
For use in hazardous locations
Test Certificates
Type Test
Certificates/Test
Report
other
Type Test
Certificates/Test
Report
Confirmation
Confirmation
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5074-2TB15
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5074-2TB15
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RW5074-2TB15
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5074-2TB15&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RW5074-2TB15/char
Characteristic: Installation altitude
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RW5074-2TB15&objecttype=14&gridview=view1
Simulation Tool for Soft Starters (STS)
https://support.industry.siemens.com/cs/ww/en/view/101494917
3RW50742TB15
Page 6/7
12.21.2020
Subject to change without notice
© Copyright Siemens
3RW50742TB15
Page 7/8
12.21.2020
Subject to change without notice
© Copyright Siemens
last modified:
3RW50742TB15
Page 8/8
12/15/2020
12.21.2020
Subject to change without notice
© Copyright Siemens