Data sheet
3RW5076-2AB15
SIRIUS soft starter 200-600 V 470 A, 110-250 V AC Spring-loaded
terminals Analog output
product brand name
SIRIUS
product category
Hybrid switching devices
product designation
Soft starter
product type designation
3RW50
manufacturer's article number
● of standard HMI module usable
3RW5980-0HS01
● of high feature HMI module usable
3RW5980-0HF00
● of communication module PROFINET standard
usable
3RW5980-0CS00
● of communication module PROFIBUS usable
3RW5980-0CP00
● of communication module Modbus TCP usable
3RW5980-0CT00
● of communication module Modbus RTU usable
3RW5980-0CR00
● of communication module Ethernet/IP
3RW5980-0CE00
● of circuit breaker usable at 400 V
3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA
● of circuit breaker usable at 500 V
3VA2580-6HN32-0AA0; Type of assignment 1, Iq = 65 kA
● of the gG fuse usable up to 690 V
2x3NA3365-6; Type of coordination 1, Iq = 65 kA
● of full range R fuse link for semiconductor protection
usable up to 690 V
3NE1 436-2; Type of coordination 2, Iq = 65 kA
● of back-up R fuse link for semiconductor protection
usable up to 690 V
3NE3 340-8; Type of coordination 2, Iq = 65 kA
● of line contactor usable up to 480 V
3RT1076
● of line contactor usable up to 690 V
3RT1076
General technical data
starting voltage [%]
30 ... 100 %
stopping voltage [%]
50 %; non-adjustable
start-up ramp time of soft starter
0 ... 20 s
ramp-down time of soft starter
0 ... 20 s
current limiting value [%] adjustable
130 ... 700 %
accuracy class according to IEC 61557-12
5%
certificate of suitability
● CE marking
Yes
● UL approval
Yes
● CSA approval
Yes
product component
● HMI-High Feature
No
● is supported HMI-Standard
Yes
● is supported HMI-High Feature
Yes
product feature integrated bypass contact system
Yes
number of controlled phases
2
trip class
CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2
3RW50762AB15
Page 1/7
7/8/2022
Subject to change without notice
© Copyright Siemens
buffering time in the event of power failure
● for main current circuit
100 ms
● for control circuit
100 ms
insulation voltage rated value
600 V
degree of pollution
3, acc. to IEC 60947-4-2
impulse voltage rated value
6 kV
blocking voltage of the thyristor maximum
1 600 V
service factor
1
surge voltage resistance rated value
6 kV
maximum permissible voltage for safe isolation
● between main and auxiliary circuit
600 V
shock resistance
15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
vibration resistance
15 mm to 6 Hz; 2g to 500 Hz
utilization category according to IEC 60947-4-2
AC-53a
reference code according to IEC 81346-2
Q
Substance Prohibitance (Date)
09/23/2019
product function
● ramp-up (soft starting)
Yes
● ramp-down (soft stop)
Yes
● Soft Torque
Yes
● adjustable current limitation
Yes
● pump ramp down
Yes
● intrinsic device protection
Yes
● motor overload protection
Yes; Electronic motor overload protection
● evaluation of thermistor motor protection
No
● auto-RESET
Yes
● manual RESET
Yes
● remote reset
Yes; By turning off the control supply voltage
● communication function
Yes
● operating measured value display
Yes; Only in conjunction with special accessories
● error logbook
Yes; Only in conjunction with special accessories
● via software parameterizable
No
● via software configurable
Yes
● PROFIenergy
Yes; in connection with the PROFINET Standard communication
module
● voltage ramp
Yes
● torque control
No
● analog output
Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature
HMI)
Power Electronics
operational current
● at 40 °C rated value
470 A
● at 50 °C rated value
416 A
● at 60 °C rated value
380 A
operating voltage
● rated value
200 ... 600 V
relative negative tolerance of the operating voltage
-15 %
relative positive tolerance of the operating voltage
10 %
operating power for 3-phase motors
● at 230 V at 40 °C rated value
132 kW
● at 400 V at 40 °C rated value
250 kW
● at 500 V at 40 °C rated value
315 kW
Operating frequency 1 rated value
50 Hz
Operating frequency 2 rated value
60 Hz
relative negative tolerance of the operating frequency
-10 %
relative positive tolerance of the operating frequency
10 %
adjustable motor current
● at rotary coding switch on switch position 1
200 A
● at rotary coding switch on switch position 2
218 A
● at rotary coding switch on switch position 3
236 A
3RW50762AB15
Page 2/7
7/8/2022
Subject to change without notice
© Copyright Siemens
● at rotary coding switch on switch position 4
254 A
● at rotary coding switch on switch position 5
272 A
● at rotary coding switch on switch position 6
290 A
● at rotary coding switch on switch position 7
308 A
● at rotary coding switch on switch position 8
326 A
● at rotary coding switch on switch position 9
344 A
● at rotary coding switch on switch position 10
362 A
● at rotary coding switch on switch position 11
380 A
● at rotary coding switch on switch position 12
398 A
● at rotary coding switch on switch position 13
416 A
● at rotary coding switch on switch position 14
434 A
● at rotary coding switch on switch position 15
452 A
● at rotary coding switch on switch position 16
470 A
● minimum
200 A
minimum load [%]
15 %; Relative to smallest settable Ie
power loss [W] for rated value of the current at AC
● at 40 °C after startup
56 W
● at 50 °C after startup
44 W
● at 60 °C after startup
37 W
power loss [W] at AC at current limitation 350 %
● at 40 °C during startup
5 344 W
● at 50 °C during startup
4 438 W
● at 60 °C during startup
3 876 W
type of the motor protection
Electronic, tripping in the event of thermal overload of the motor
Control circuit/ Control
type of voltage of the control supply voltage
AC
control supply voltage at AC
● at 50 Hz
110 ... 250 V
● at 60 Hz
110 ... 250 V
relative negative tolerance of the control supply
voltage at AC at 50 Hz
-15 %
relative positive tolerance of the control supply
voltage at AC at 50 Hz
10 %
relative negative tolerance of the control supply
voltage at AC at 60 Hz
-15 %
relative positive tolerance of the control supply
voltage at AC at 60 Hz
10 %
control supply voltage frequency
50 ... 60 Hz
relative negative tolerance of the control supply
voltage frequency
-10 %
relative positive tolerance of the control supply
voltage frequency
10 %
control supply current in standby mode rated value
30 mA
holding current in bypass operation rated value
105 mA
locked-rotor current at close of bypass contact
maximum
2.2 A
inrush current peak at application of control supply voltage
maximum
12.2 A
duration of inrush current peak at application of control
supply voltage
2.2 ms
design of the overvoltage protection
Varistor
design of short-circuit protection for control circuit
4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature
circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is
not part of scope of supply
Inputs/ Outputs
number of digital inputs
1
number of digital outputs
3
● not parameterizable
2
digital output version
2 normally-open contacts (NO) / 1 changeover contact (CO)
number of analog outputs
1
switching capacity current of the relay outputs
● at AC-15 at 250 V rated value
3RW50762AB15
Page 3/7
3A
7/8/2022
Subject to change without notice
© Copyright Siemens
● at DC-13 at 24 V rated value
1A
Installation/ mounting/ dimensions
mounting position
with vertical mounting surface +/-90° rotatable, with vertical mounting
surface +/- 22.5° tiltable to the front and back
fastening method
screw fixing
height
230 mm
width
160 mm
depth
282 mm
required spacing with side-by-side mounting
● forwards
10 mm
● backwards
0 mm
● upwards
100 mm
● downwards
75 mm
● at the side
5 mm
weight without packaging
7.3 kg
Connections/ Terminals
type of electrical connection
● for main current circuit
busbar connection
● for control circuit
spring-loaded terminals
width of connection bar maximum
35 mm; with connection cover 3RT1966-4EA1 maximum length 45 mm
type of connectable conductor cross-sections
● for main contacts for box terminal using the front
clamping point solid
95 ... 300 mm²
● for main contacts for box terminal using the front
clamping point finely stranded with core end
processing
70 ... 240 mm²
● for main contacts for box terminal using the front
clamping point finely stranded without core end
processing
70 ... 240 mm²
● for main contacts for box terminal using the front
clamping point stranded
95 ... 300 mm²
● at AWG cables for main contacts for box terminal
using the front clamping point
3/0 ... 600 kcmil
● for main contacts for box terminal using the back
clamping point solid
120 ... 240 mm²
● at AWG cables for main contacts for box terminal
using the back clamping point
250 ... 500 kcmil
● for main contacts for box terminal using both
clamping points solid
min. 2x 70 mm², max. 2x 240 mm²
● for main contacts for box terminal using both
clamping points finely stranded with core end
processing
min. 2x 50 mm², max. 2x 185 mm²
● for main contacts for box terminal using both
clamping points finely stranded without core end
processing
min. 2x 50 mm², max. 2x 185 mm²
● for main contacts for box terminal using both
clamping points stranded
min. 2x 70 mm², max. 2x 240 mm²
● for main contacts for box terminal using the back
clamping point finely stranded with core end
processing
120 ... 185 mm²
● for main contacts for box terminal using the back
clamping point finely stranded without core end
processing
120 ... 185 mm²
● for main contacts for box terminal using the back
clamping point stranded
120 ... 240 mm²
type of connectable conductor cross-sections
● at AWG cables for main current circuit solid
2/0 ... 500 kcmil
● for DIN cable lug for main contacts stranded
50 ... 240 mm²
● for DIN cable lug for main contacts finely stranded
70 ... 240 mm²
type of connectable conductor cross-sections
● for control circuit solid
2x (0.25 ... 1.5 mm²)
● for control circuit finely stranded with core end
processing
2x (0.25 ... 1.5 mm²)
● at AWG cables for control circuit solid
2x (24 ... 16)
● at AWG cables for control circuit finely stranded with
2x (24 ... 16)
3RW50762AB15
Page 4/7
7/8/2022
Subject to change without notice
© Copyright Siemens
core end processing
wire length
● between soft starter and motor maximum
800 m
● at the digital inputs at AC maximum
1 000 m
tightening torque
● for main contacts with screw-type terminals
14 ... 24 N·m
● for auxiliary and control contacts with screw-type
terminals
0.8 ... 1.2 N·m
tightening torque [lbf·in]
● for main contacts with screw-type terminals
124 ... 210 lbf·in
● for auxiliary and control contacts with screw-type
terminals
7 ... 10.3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum
5 000 m; derating as of 1000 m, see Manual
ambient temperature
● during operation
-25 ... +60 °C; Please observe derating at temperatures of 40 °C or
above
● during storage and transport
-40 ... +80 °C
environmental category
● during operation according to IEC 60721
3K6 (no ice formation, only occasional condensation), 3C3 (no salt
mist), 3S2 (sand must not get into the devices), 3M6
● during storage according to IEC 60721
1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must
not get inside the devices), 1M4
● during transport according to IEC 60721
2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
EMC emitted interference
acc. to IEC 60947-4-2: Class A
Communication/ Protocol
communication module is supported
● PROFINET standard
Yes
● EtherNet/IP
Yes
● Modbus RTU
Yes
● Modbus TCP
Yes
● PROFIBUS
Yes
UL/CSA ratings
manufacturer's article number
● of the fuse
— usable for Standard Faults up to 575/600 V
according to UL
Type: Class L, max. 1600 A; Iq = 30 kA
— usable for High Faults up to 575/600 V
according to UL
Type: Class L, max. 1200 A; Iq = 100 kA
operating power [hp] for 3-phase motors
● at 200/208 V at 50 °C rated value
150 hp
● at 220/230 V at 50 °C rated value
150 hp
● at 460/480 V at 50 °C rated value
350 hp
● at 575/600 V at 50 °C rated value
450 hp
Safety related data
protection class IP on the front according to IEC
60529
IP00; IP20 with cover
touch protection on the front according to IEC 60529
finger-safe, for vertical contact from the front with cover
ATEX
certificate of suitability
● ATEX
Yes
● IECEx
Yes
hardware fault tolerance according to IEC 61508
relating to ATEX
0
PFDavg with low demand rate according to IEC 61508
relating to ATEX
0.09
PFHD with high demand rate according to EN 62061
relating to ATEX
9E-6 1/h
Safety Integrity Level (SIL) according to IEC 61508
relating to ATEX
SIL1
T1 value for proof test interval or service life
according to IEC 61508 relating to ATEX
3y
3RW50762AB15
Page 5/7
7/8/2022
Subject to change without notice
© Copyright Siemens
Certificates/ approvals
For use in hazardous locations
General Product Approval
Confirmation
For use in hazardous locations
Declaration of
Conformity
Test Certificates
Marine / Shipping
Type Test Certificates/Test Report
other
Confirmation
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5076-2AB15
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5076-2AB15
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3RW5076-2AB15
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5076-2AB15&lang=en
Characteristic: Tripping characteristics, I²t, Let-through current
https://support.industry.siemens.com/cs/ww/en/ps/3RW5076-2AB15/char
Characteristic: Installation altitude
http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RW5076-2AB15&objecttype=14&gridview=view1
Simulation Tool for Soft Starters (STS)
https://support.industry.siemens.com/cs/ww/en/view/101494917
last modified:
3RW50762AB15
Page 6/7
4/11/2022
7/8/2022
Subject to change without notice
© Copyright Siemens
3RW50762AB15
Page 7/7
7/8/2022
Subject to change without notice
© Copyright Siemens
很抱歉,暂时无法提供与“3RW50762AB15”相匹配的价格&库存,您可以联系我们找货