Data sheet
3SK1121-2CB42
SIRIUS safety relay Basic unit Advanced series with time delay 0.5-30 s Relay
enabling circuits 2 NO instantaneous 2 NO delayed Us = 24 V DC Spring-type
terminal (push-in)
product brand name
SIRIUS
product category
Safety relays
product designation
safety relays
design of the product
Relay enabling circuits
General technical data
protection class IP of the enclosure
IP20
touch protection against electrical shock
finger-safe
insulation voltage rated value
300 V
ambient temperature
● during storage
-40 ... +80 °C
● during operation
-25 ... +60 °C
air pressure according to SN 31205
90 ... 106 kPa
relative humidity during operation
10 ... 95 %
installation altitude at height above sea level maximum
4 000 m; Derating, see Product Notification 109792701
vibration resistance according to IEC 60068-2-6
5 ... 500 Hz: 0.75 mm
shock resistance
10g / 11 ms
surge voltage resistance rated value
4 000 V
EMC emitted interference
IEC 60947-5-1, Class A
installation environment regarding EMC
This product is suitable for Class A environments only. In household
environments, this device can cause unwanted radio interference. The user is
required to implement appropriate measures in this case.
overvoltage category
3
degree of pollution
3
reference code according to IEC 81346-2
F
power loss [W] maximum
2.5 W
number of sensor inputs 1-channel or 2-channel
1
design of the cascading
yes
type of the safety-related wiring of the inputs
single-channel and two-channel
product feature cross-circuit-proof
Yes
Safety Integrity Level (SIL)
● according to IEC 62061
3
● according to IEC 61508
3
● for delayed release circuit according to IEC 61508
SIL3
performance level (PL)
● according to ISO 13849-1
e
● for delayed release circuit according to ISO 13849-1
e
category according to EN ISO 13849-1
4
Safe failure fraction (SFF)
99 %
PFHD with high demand rate according to IEC 62061
3.7E-9 1/h
PFDavg with low demand rate according to IEC 61508
7E-6
T1 value for proof test interval or service life according to
20 a
3SK11212CB42
Page 1/5
4/5/2024
Subject to change without notice
© Copyright Siemens
IEC 61508
hardware fault tolerance according to IEC 61508
1
safety device type according to IEC 61508-2
Type B
Inputs/ Outputs
number of outputs as contact-affected switching element
● as NO contact
— safety-related instantaneous contact
2
— safety-related delayed switching
2
stop category according to IEC 60204-1
0/1
design of input
● cascading input/functional switching
Yes
● feedback input
Yes
● start input
Yes
type of electrical connection plug-in socket
No
operating frequency maximum
360 1/h
switching capacity current
● of the NO contacts of the relay outputs
— at DC-13
— at 24 V
3A
— at 115 V
0.2 A
— at 230 V
0.1 A
— at AC-15
— at 115 V
3A
— at 230 V
3A
thermal current of the switching element with contacts
maximum
5A
total current maximum
12 A
operational current at 17 V minimum
5 mA
mechanical service life (operating cycles) typical
10 000 000
design of the fuse link for short-circuit protection of the NO
contacts of the relay outputs required
gL/gG: 6A or circuit breaker type A: 3A or circuit breaker type B: 2A or circuit
breaker type C: 1A
wire length
● with Cu 1.5 mm² and 150 nF/km per sensor circuit
maximum
4 000 m
make time with automatic start
● at DC maximum
110 ms
make time with automatic start after power failure
● typical
6 500 ms
● maximum
6 500 ms
make time with monitored start
● maximum
backslide delay time after opening of the safety circuits
typical
110 ms
40 ms
backslide delay time in the event of power failure
● typical
30 ms
● maximum
40 ms
adjustable OFF-delay time after opening of the safety
circuits
0.5 ... 30
recovery time after opening of the safety circuits typical
30 ms
recovery time after power failure typical
6.5 s
pulse duration
● of the sensor input minimum
75 ms
● of the ON pushbutton input minimum
0.15 s
Control circuit/ Control
type of voltage of the control supply voltage
DC
control supply voltage
● at DC rated value
—
24 V
operating range factor control supply voltage rated value of
magnet coil
● at DC
0.8 ... 1.2
Installation/ mounting/ dimensions
3SK11212CB42
Page 2/5
4/5/2024
Subject to change without notice
© Copyright Siemens
mounting position
any
required spacing for grounded parts at the side
5 mm
fastening method
screw and snap-on mounting
width
22.5 mm
height
100 mm
depth
121.6 mm
Connections/ Terminals
type of electrical connection
spring-loaded terminal (push-in)
type of connectable conductor cross-sections
● solid
1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
● finely stranded
— with core end processing
1x (0.5 ... 1.0 mm²), 2x (0.5 ... 1.0 mm²)
— without core end processing
1x (0.5 ... 1.5 mm²), 2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections for AWG
cables
● solid
1x (20 ... 16), 2x (20 ... 16)
● stranded
1x (20 ... 16), 2x (20 ... 16)
Product Function
product function parameterizable
sensor floating / sensor non-floating, monitored start-up / automatic start, 1channel / 2-channel sensor connection, cross-circuit detection, startup testing,
antivalent sensors, 2-hand switches, time delay
suitability for operation device connector 3ZY12
Yes
suitability for interaction press control
Yes
suitability for use
● safety switch
Yes
● monitoring of floating sensors
Yes
● monitoring of non-floating sensors
Yes
● magnetically operated switch monitoring
Yes
● safety-related circuits
Yes
Certificates/ approvals
General Product Approval
Confirmation
General Product Approval
EMV
Functional Saftey
Type Examination Certificate
Marine / Shipping
other
Test Certificates
Marine / Shipping
Type Test Certificates/Test Report
Railway
Confirmation
Confirmation
Environment
Environmental Confirmations
Further information
Information on the packaging
https://support.industry.siemens.com/cs/ww/en/view/109813875
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3SK1121-2CB42
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3SK1121-2CB42
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3SK1121-2CB42
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
3SK11212CB42
Page 3/5
4/5/2024
Subject to change without notice
© Copyright Siemens
13
23
37
47
14
24
38
48
INS
INF
T2
IN2
PAR
T1
IN1
INK
A1+
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3SK1121-2CB42&lang=en
-K
1 | Autostart / Monitored Start
Logic
SYS
2 | Cross fault detection OFF / ON
3 | 2 single-ch. sensors / 1 double-ch. sensor
4 | Startup Test yes / no
A2-
SET / RESET
3SK11212CB42
Page 4/5
4/5/2024
Subject to change without notice
© Copyright Siemens
13
23
37
47
14
24
38
48
INS
INF
T2
IN2
PAR
T1
IN1
INK
A1+
-K
1 | Autostart / Monitored Start
Logic
SYS
2 | Cross fault detection OFF / ON
3 | 2 single-ch. sensors / 1 double-ch. sensor
4 | Startup Test yes / no
A2-
SET / RESET
last modified:
3SK11212CB42
Page 5/5
3/11/2024
4/5/2024
Subject to change without notice
© Copyright Siemens