Data sheet
3UG4512-2AR20
Analog monitoring relay Phase failure and sequence 3 x 160...690 V
50...60 Hz AC 1 change-over contact spring-type connection system
product brand name
SIRIUS
product designation
Network monitoring relay with analog setting
design of the product
2 functions
product type designation
3UG4
General technical data
product function
Phase monitoring relay
display version LED
Yes
insulation voltage for overvoltage category III according to
IEC 60664
● with degree of pollution 3 rated value
degree of pollution
690 V
3
type of voltage
● for monitoring
AC
● of the control supply voltage
AC
surge voltage resistance rated value
6 kV
protection class IP
IP20
shock resistance according to IEC 60068-2-27
sinusoidal half-wave 15g / 11 ms
vibration resistance according to IEC 60068-2-6
1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
mechanical service life (switching cycles) typical
10 000 000
electrical endurance (switching cycles) at AC-15 at 230 V
typical
100 000
thermal current of the switching element with
contacts maximum
5A
reference code according to IEC 81346-2
K
relative repeat accuracy
1%
Substance Prohibitance (Date)
05/01/2012
Product Function
product function
● undervoltage detection
No
● overvoltage detection
No
● phase sequence recognition
Yes
● phase failure detection
Yes
● asymmetry detection
No
● overvoltage detection 3 phase
No
● undervoltage detection 3 phases
No
● voltage window recognition 3 phase
No
● adjustable open/closed-circuit current principle
No
● auto-RESET
Yes
Control circuit/ Control
control supply voltage at AC
3UG45122AR20
Page 1/4
7/4/2022
Subject to change without notice
© Copyright Siemens
● at 50 Hz rated value
160 ... 690 V
● at 60 Hz rated value
160 ... 690 V
operating range factor control supply voltage rated
value at AC at 50 Hz
● initial value
1
● full-scale value
1
operating range factor control supply voltage rated
value at AC at 60 Hz
● initial value
1
● full-scale value
1
Measuring circuit
measurable voltage at AC
690 ... 160 V
Auxiliary circuit
number of NC contacts delayed switching
0
number of NO contacts delayed switching
0
number of CO contacts delayed switching
1
operating frequency with 3RT2 contactor maximum
5 000 1/h
Main circuit
number of poles for main current circuit
3
ampacity of the output relay at AC-15
● at 250 V at 50/60 Hz
3A
● at 400 V at 50/60 Hz
3A
ampacity of the output relay at DC-13
● at 24 V
1A
● at 125 V
0.2 A
● at 250 V
0.1 A
operational current at 17 V minimum
5 mA
continuous current of the DIAZED fuse link of the
output relay
4A
Electromagnetic compatibility
conducted interference
● due to burst according to IEC 61000-4-4
2 kV
● due to conductor-earth surge according to IEC
61000-4-5
2 kV
● due to conductor-conductor surge according to IEC
61000-4-5
1 kV
field-based interference according to IEC 61000-4-3
10 V/m
electrostatic discharge according to IEC 61000-4-2
6 kV contact discharge / 8 kV air discharge
Galvanic isolation
galvanic isolation
● between input and output
Yes
● between the outputs
Yes
● between the voltage supply and other circuits
Yes
Connections/ Terminals
product component removable terminal for auxiliary
and control circuit
Yes
type of electrical connection
spring-loaded terminals
type of connectable conductor cross-sections
● solid
2x (0.25 ... 1.5 mm²)
● finely stranded with core end processing
2 x (0.25 ... 1.5 mm²)
● finely stranded without core end processing
2x (0.25 ... 1.5 mm²)
● at AWG cables solid
2x (24 ... 16)
● at AWG cables stranded
2x (24 ... 16)
connectable conductor cross-section
● solid
0.25 ... 1.5 mm²
● finely stranded with core end processing
0.25 ... 1.5 mm²
● finely stranded without core end processing
0.25 ... 1.5 mm²
AWG number as coded connectable conductor cross
section
● solid
24 ... 16
● stranded
24 ... 16
3UG45122AR20
Page 2/4
7/4/2022
Subject to change without notice
© Copyright Siemens
Installation/ mounting/ dimensions
mounting position
any
fastening method
snap-on mounting
height
84 mm
width
22.5 mm
depth
91 mm
required spacing
● with side-by-side mounting
— forwards
0 mm
— backwards
0 mm
— upwards
0 mm
— downwards
0 mm
— at the side
0 mm
● for grounded parts
— forwards
0 mm
— backwards
0 mm
— upwards
0 mm
— at the side
0 mm
— downwards
0 mm
● for live parts
— forwards
0 mm
— backwards
0 mm
— upwards
0 mm
— downwards
0 mm
— at the side
0 mm
Ambient conditions
installation altitude at height above sea level maximum
2 000 m
ambient temperature
● during operation
-25 ... +60 °C
● during storage
-40 ... +85 °C
● during transport
-40 ... +85 °C
Certificates/ approvals
General Product Approval
EMC
Declaration of
Conformity
other
Railway
Confirmation
Test Certificates
Type Test Certificates/Test Report
Marine / Shipping
Special Test Certificate
Confirmation
Vibration and Shock
Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
https://www.siemens.com/ic10
Industry Mall (Online ordering system)
https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3UG4512-2AR20
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UG4512-2AR20
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3UG4512-2AR20
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UG4512-2AR20&lang=en
Characteristic: Derating
https://support.industry.siemens.com/cs/ww/en/ps/3UG4512-2AR20/manual
3UG45122AR20
Page 3/4
7/4/2022
Subject to change without notice
© Copyright Siemens
last modified:
3UG45122AR20
Page 4/4
12/21/2020
7/4/2022
Subject to change without notice
© Copyright Siemens